Laserfiche WebLink
SENSEITm TECHNICAL • • • • in. (mm) <br /> SPECIFICATION RUR199i I RUR160i FRONT <br /> Dimensions-w,h,d 18.5 in.x 26.4 in.x 11.4 in. (470 mm x 670 mm x 290 mm) 5 Y <br /> (Isoj� <br /> Minimum Gas Consumption 15,000 <br /> Btu/h <br /> Maximum Gas Consumption 199,000 160,000 ? <br /> Btu/h 9 m <br /> Flow Rate' 0.26-9.8 GPM 0.26-8.0 GPM _ <br /> (Min-Max) (1.0-37 L/min) (1.0-30 L/min) <br /> Max Flow Rate with 11 GPM 9 GPM <br /> Parameter Adjustment (42 L/min) (34 L/min) <br /> Weight 73 lb(33 kg) 71 Ib(32 kg) `9'•c <br /> Qo n= <br /> Sound Level49 d8 48 dB n n <br /> Normal 84 W 52W <br /> Ta Standby 1.3 W <br /> Freeze Protection 160 W <br /> Zi Max Current 4Amps <br /> Fuse 10 Amps I <br /> • Minimum: 98°F f37°C Default I„ 18.5 <br /> Temperature 120°F(49°C)Crossover Mode I'�14/01 <br /> • Maximum: 120°F(49°C)Default SIDE <br /> 140°F 60°C)With Parameter Adjustment 608 <br /> By-Pass Flow Control Electronic (154) Vent[onnection: <br /> Gas Supply Pressure' • Natural: 3.5 in.w.c.-10.5 in.w.c. 2 in.(51 mm) <br /> • Propane: 8.0 in.w.c.-13.5 in.w.c. <br /> Ignition System Direct Electronic Ignition nominal PVC/ <br /> • Appliance: AC 120 Volts,60Hz. Polypropylene or <br /> Electronic Connections • Temperature Controller: DC 12 Volts(Digital) 3 in./5 in. <br /> • Minimum: 50 PSI(Recommended 60-80 PSI for max Concentric. <br /> Water Supply Pressure performance) <br /> • Maximum: 150 PSI N <br /> Controller Cable Non-Polarized Two Core Cable(Minimum 22 AWG) <br /> • Gas Supply: 3/4 in.(19 mm)NPT <br /> • Cold Water Inlet: 3/4 in.(19 mm)NPT <br /> Service Connections • Hot Water Outlet: 3/4 in.(19 mm)NPT <br /> • Condensate Drain: 1/2 in.(13 mm)NPT <br /> • Top: 2 in.(51 mm)* • Back: 0 in. <br /> Clearances • Bottom/Ground:12 in.(305 mm) • Sides:2 in.(51 mm)*** <br /> • Front:0 in.** • Vent: Din. -_11.45 <br /> 0 in.from vent components (290) <br /> ** Clearance for servicing is 24 in.(610 mm)In front of water heater BOTTOM <br /> ***Add 0.251n.(6.35 mm)for recess box <br /> 'Minimum flow may vary slightly dependingg on the temperature setting and the inlet water temperature. <br /> Minimum activation flow Is 0.4 GPM(1.5 No). FUF <br /> 'The maximum gas supply pressure must not exceed the value specified by the manufacturer. •�• <br /> SENSE11"WATER FLOW CURVE <br /> f� <br /> Flow curves apply only to incoming water temperatures of 70°F(21°C)or less. - <br /> For incoming water temperatures greater than)0°F(21°C),please contact Rinnai. - ) • <br /> 12 <br /> NOTE:Maximum Flow rates may vary based <br /> RUR1991 - - ' on set temperature,Delta T and altitude. - p <br /> -77 <br /> RUR1601 6 I _ - H �- <br /> 7 - <br /> t'o 6 ----- - __ —__-- °COLD ° F 9.27 235 <br /> c 5 _ - _ _ C 3.11 79 <br /> 4 - - - I - HOT H 14.49 368 <br /> 3 3 - B 6.52 166 <br /> 2 -A Dashed lines represent flow rate -- - GAS E 3.57 91 <br /> 1 ' after parameter adju-t=ent -- - - - - - _= D 2.79 71 <br /> G 10.40 264 <br /> 0 n i -76 Im PRV A 7.60 193 <br /> Rinnal America Corporation•103 International Drive,Peachtree City,GA 30269•1-800-621-9419•rinnaws <br /> c62018 Rinnai America Corporation.Rinnai America Corporation continually updates materials,and as such.content is subject to change without notice. <br /> Local,state,provincial.federal and national fuel gas codes must be adhered to prior to and upon installation. 8/2018 RURi-SP-2 <br /> SENSEI" Residential with Pump Indoor Spec Sheet <br />