My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1330
>
2300 - Underground Storage Tank Program
>
PR0515864
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2021 11:32:07 AM
Creation date
1/5/2021 8:17:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0515864
PE
2361
FACILITY_ID
FA0012355
FACILITY_NAME
A&A GAS FOOD MART
STREET_NUMBER
1330
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120053
CURRENT_STATUS
01
SITE_LOCATION
1330 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Overfill Prevention Equipment Inspection Report For <br /> 6 . OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID (One OPE per column) 87 91 DSL DSL <br /> Are both vent and tank riser piping ❑ Yes ❑ Yes ❑ Yes ❑ Yes <br /> secondarily contained ? ® No ® No ® No ® No <br /> OPE Model Ball float Ball float OPW OPW <br /> Tank Manufacturer Xerxes Xerxes Xerxes Xerxes <br /> ❑ Shuts off ❑ Shuts off ® Shuts off ® Shuts off <br /> Flow Flow Flow Flow <br /> What is the OPE response when ® Restricts ® Restricts ❑ Restricts ❑ Restricts <br /> activated ? Flow Flow Flow Flow <br /> (Check all that apply.) ❑ Audible ❑ Audible ❑ Audible ❑ Audible <br /> Alarm Alarm Alarm Alarm <br /> ❑Visual ❑Visual ❑Visual ❑Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent ® Yes ® Yes ElYes ® Yes <br /> piping that may interfere with the OPE ❑ No ❑ No ® No ❑ No <br /> operation ? <br /> At what level in the tank is the OPE set to 95.. 95" 115" 1003/4 <br /> activate? (Inches from bottom of tank) <br /> What is the percent capacity of the tank in 90 % 90 % 98 % 93 % <br /> which the OPE activates ? <br /> Is the OPE in proper operating condition ® Yes ® Yes ❑ Yes ® Yes <br /> to respond when the stored substance 171 No 171 No ® No 171 No <br /> reaches the designated regulatory level ? <br /> 7 . SUMMARY OF TESTING RESULTS <br /> OPE Inspection Results ® Pass ® Pass ❑ Pass !Fo: <br /> Pass <br /> ❑ Fail El Fall ® Fail Fail <br /> 8 . COMMENTS <br /> 12/28/2020 - Arrived on site to replace EMCO drop tubes at site's request. Discovered 87 and 91 <br /> are ball float and passed overfill . DSL is OPW and failed . Need to return to replace DSL drop tube <br /> and retest. <br /> 1 /8/2021 - Built new drop tube at set at 93% . Installed drop tube and tested with county. <br /> Overfill passed . <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.