10 =20000 DWT6 Double -Wall Tank <br /> 19951 Gals <br /> DIPSTICK GALLONS DIPSTICK GALLONS <br /> 1081 /8 19059 1141 /8 19659 <br /> 108 1 /4 19074 114 1 /4 19669 <br /> 108 3/8 19088 114 3/8 19679 k` <br /> 108 1 /2 19103 _ 114 1 /2 19689 <br /> 108 5/8 19117 114 5/8 19698 CONTAINMENT <br /> 108 3/4 19131 114 3/4 19708 S Q L U T I O N So <br /> 108 7/8 19146 114 7/8 19717 <br /> 109 19160 115 19726 <br /> 109 1 /8 19174 _ 115 1 /8 19735 How To Properly Gauge Your Tank <br /> _ 109 1 /4 _ 19188 115 1 /4 19744 Underground storage tanks require periodic measurement to determine current Inventory level . <br /> 109 3/8 19202 115 3/8 19753 Using the proper methods when gauging your tank's contents will insure the most accurate reading <br /> and insure that you do not damage your tank. The following procedure should be followed <br /> 109 1 /2 19215 115 1 /2 19762 whenever you use a gauge stick to determine the amount of product that is in your tank: <br /> 109 6/8 19229 115 5/8 19770 1 ) Use a wood dipstick with a rubber or nylon tip. Metallic dipsticks are not recommended . This <br /> 109 3/4 19243 115 3/4 19779 will Insure that frequent tank gaugings or an accidental dropping of the gauge stick Into the tank <br /> will not damage the tank bottom . <br /> 109 7/8 19256 115 7/8 19787 2) Slowly lower your gauge stick Into the fill port until it touches the tank bottom. Never free drop <br /> 110 19270 116 19795 the gauge stick. This can result in inaccurate measurements due to product splashing . Free <br /> - -- - -- — - dropping can also result in gauge stick damage and tank damage. <br /> 110 1 /8 19283 116 1 /8 19803 3) Remove your dipstick slowly and read the product level directly from the gauge stick. <br /> 110 1 /4 19296 116 1 /4 19811 <br /> Water Paste Detection <br /> 110 3/8 19310 116 3/8 19819 <br /> To detect water in the tank bottom , water detection paste is available from petroleum equipment <br /> 110 1 /2 19323 116 1 /2 19826 distributors . However, some water detection paste cannot detect antifreeze mixtures . If antifreeze <br /> 110 5/8 19336 116 5/8 19834 mixtures are used for the cavity monitoring fluid , the following product is capable of detecting water <br /> or antifreeze (brine or up to 50 percent glycol ) solution in the tank water bottoms : <br /> 110 3/4 19349 116 3/4 19841 WATER FINDER #7686-1870 <br /> 110 7/8 19361 116 718 19848 DAYCO/NATIONAL <br /> 111 19374 117 19855 DAYTON , OH <br /> TEL: 1 -800-283-2926 <br /> 111 1 /8 19387 117 1 /8 19862 FAX: 1 -800-6884854 <br /> _ 111 1 /4 19399 117 1 /4 19868 Caution <br /> 111 3/8 19412 117 3/8 19875 Pressurized deliveries are not recommended. If the delivery vehicle uses pumps to fill the tank, <br /> 111 1 /2 19424 117 1 /2 19881 install overfill shutoff equipment in the tank and truck to prevent the tank from being overfilled. <br /> 111 518 19436 117 5/8 19887 Overfilling the tank under pressure will damage the tank even if the tank vent is <br /> -- unrestricted. <br /> 111 3/4 19448 117 3/4 19893 <br /> 111 7/8 19460 117 7/8 19898 Containment Solutions , Inc. <br /> 333 North Rivershire Dr., Suite 190 <br /> 112 19472 118 19904 Conroe, TX 77304 <br /> 112 1 /8 19484 118 1 /8 19909 Tel . 936=756u7731 <br /> 112 1 /4 19496 _ 118 1 /4 . 19914 Fax; 936.756.7766 <br /> 112 3/8 19508 118 3/8 19919 <br /> 112 1 /2 _ 19519 _ 118 1J2 19923 Note : Calibration chart is based on the fluid level above a 5116" deflector plate . <br /> 112 5/8 19530 118 5/8 19928 <br /> 112 3/4 19_542 118 3/4 1,9932 <br /> 112 7/8 19553 118 7/8 19936 <br /> 113 19564 119 19939 <br /> 113 1 /8 19575 119 1 /8 19942 <br /> 113 1 /4 19586 119 1 /4 19945 <br /> 113 3/8 19597 119 3/8 19948 <br /> 113 1 /2 19607 119 1 /2 19950 <br /> 113 5/8 19618 119 5/8 19951 <br /> 113 3/4 19a <br /> 113 7/8 19639 <br /> 114 19649 Lj <br /> Containment Solutions , Inc . 4 <br />