Laserfiche WebLink
Site: FJO � <br /> ( -L Appendix B Date: 7/74/Zi <br /> 7150 Overfill Valve in Tank Shut off Level Worksheet Tank ID Tester <br /> Important: This is meant to be supplemental worksheet and not a substitute to following the installation <br /> manual instructions. All length measurements are in inches. Please contact the Authority Having Jurisdic- <br /> tion (AHJ)and review local,state,and national codes to determine the regulatory requirements governing <br /> shut-off capacity in your region,as well as take into account other considerations such as extreme tank tilt. <br /> Take the following measurements with the valve in- l_ <br /> stalled in the tank: <br /> Distance from the 71 SO inlet tube flange to the cast <br /> lug in the 71 SO body(see figures),upper tube length. <br /> Note: the Upper Tube Length must be at least 16"to in- <br /> clude the protective bend in the tube. <br /> Distance from the 71 SO inlet tube flange to the top and <br /> bottom of lower tube,valve length. <br /> (W) (D) <br /> (U)_��—— =1 y Tpu ber <br /> —c <br /> Distance from the 71 SO inlet tube flange to the bottom J <br /> of the tank. Note:If a tank bottom protector is present it <br /> may be necessary to add this thickness to dimension <br /> (OPW 6111 &61 TP models add 0.6") (W)Valve <br /> (B)_ Length, <br /> bottom of <br /> From the tank calibration chart provided by tank manu- cut <br /> facturer find the dipstick number(Y)which corresponds $� <br /> to the 100%volume. (B) <br /> (Y)=- er __ MVV' To Tank <br /> i <br /> I� <br /> 1. To determine shut-off percentage: Tank <br /> Subtract upper tube length (D)from distance to tank (U)Valve Chart II <br /> bottom (B) / } Length, 100% <br /> (X) _(B)-(D)-2"= /J /�� top of cut Volume <br /> Dipstick L <br /> Using the tank calibration chart provided by the tank i <br /> manufacturer determine the tank capacity at the cal- <br /> culated (X) dimension and the 100%volume(Y)tank Ir <br /> capacity. <br /> pp � <br /> (X)tank capacity in gallons <br /> � <br /> (Y)tank capacity in gallons=IL V <br /> 50%_ (X)capacity/(Y)capacity x100=/ /`� �y. <br /> Note: The overfill valve must be installed per AHJ require- <br /> ments and all applicable local,state,and national codes. If <br /> the overfill valve is set above the allowable shut-off percent- <br /> age the overfill valve must be removed and replaced. For <br /> reference 40 CFR part 280 Subpart B Section 280.20 overfill <br /> valves should be set to a maximum of 95%. <br /> 21 <br />