Laserfiche WebLink
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for EI Dorado Gas & Mart as of December 24, 2020. <br /> Open violations from November 06, 2020 inspection <br /> This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: Th ig vi nl a t i on ha e heRn cnrrectRd h:4 <br /> removing asoline from the UST until the station and food mart renovation is completed. <br /> Detailed inSipection of UST and monitoring systems will be repeated once new dispensers are <br /> installed and before goinct live again early March 2021 <br /> Violation#314-Failure to continuously monitor interstitial space with audible-visual alarm system(pre-Jul <br /> 2004). <br /> OBSERVATION:The 87 and 91 underground tank systems at this facility are no longer in use. According to the <br /> owner,Aziz Sher,the monitoring panel was disconnected and removed approximately three weeks ago. The <br /> system is not currently being monitored for leaks. <br /> REGULATION GUIDANCE:The interstitial space shall be monitored with a monitoring system connected to an <br /> audible and visual alarm system. <br /> CORRECTIVE ACTION: Correct immediately by having a property licensed,trained,and certified contractor restore <br /> all monitoring to this system,or remove all fuel from the USTs within 48 hours and immediately comply with closure <br /> requirements. <br /> CR This violation was corrected ❑This violation will be corrected by(date)-- <br /> 0 <br /> date)_❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: This violation has been corrected by_.. <br /> removing asoline from the UST until the station and food mart renovation is com leted. <br /> Derailed insipecHnn ot UST and monitoring s stems will he rene-ated once jaew dispenaars are <br /> installed and before going live again early March 2021 <br /> Violation#321 -Leak detection equipment disabled or tampered with. <br /> OBSERVATION:The 87 and 91 underground tank systems at this facility are no longer in use. According to the <br /> owner,Aziz Sher,the monitoring panel was disconnected and removed approximately three weeks ago. <br /> REGULATION GUIDANCE:An operator of an underground storage tank system shall not allow tampering with or <br /> otherwise disabling automatic leak detection devices or alarms_ <br /> CORRECTIVE ACTION: Immediately take all necessary actions to bring these UST systems into compliance. <br /> Immediately restore all monitoring to this system,or remove all fuel from the USTs within 48 hours and immediately <br /> comply with closure requirements. <br /> Page 4 of 8 <br />