Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Page 1 of 6) <br /> Type of Action ❑ Installation Test ❑ Repair Test ❑x Six Month Test ❑36 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10184349 9/18/2020 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Pilot Flying J #617 <br /> Business Site Address City ZIP Code <br /> 15237 N Thornton Lodi 95242 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification) Phone# <br /> Jose Ochoa (888) 972-7581 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 804431 A,B HAZ 8004551-UT 10/28/2021 <br /> III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID: (By tank number,stored product, etc.) A T-5 91 B C D <br /> Tank Containment <br /> Tightness Test Result ❑Pass ❑Fail ENA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA <br /> Product Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail ENA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA <br /> Communication Test Result ❑Pass ❑Fail ENA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail ZNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA <br /> Communication Test Result ❑Pass ❑Fail ENA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA <br /> Vent Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail ENA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA <br /> Communication Test Result ❑Pass ❑Fail ENA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail ENA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA <br /> Communication Test Result ❑Pass ❑Fail ENA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA <br /> Turbine/Product Piping Sump <br /> Tightness Test Result ZPass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA <br /> Fill Riser Sump <br /> Tightness Test Result EPass ❑Fail DNA ❑Pass ❑Fail ❑NA ❑Pass ❑Fail DNA ❑Pass ❑Fail ❑NA <br /> VENT/TRANSITION SUMP ID: a b C d <br /> Tightness Test Result ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA <br /> UDC ID: 1 2 3 4 <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA <br /> UDC ID: 5 6 7 8 <br /> Tightness Test Result ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA <br /> UDC ID: 9 10 11 12 <br /> Tightness Test Result ❑Pass ED]Fail DNA ❑Pass ❑Fail DNA ❑Pass ❑Fail DNA [:]Pass ❑Fail DNA <br /> All items marked"Fail"or"NA"must be explained in their respective"COMMENTS"section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the secondary containment was tested in accordance with California Code of Regulations,Title 23,Division <br /> 3, Chapter 16, Section 2637 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> r <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,NA=Not Applicable,UDC=Under- <br /> Dispenser Containment <br />