My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
153
>
2300 - Underground Storage Tank Program
>
PR0231389
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:34 AM
Creation date
1/8/2021 2:26:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231389
PE
2361
FACILITY_ID
FA0003709
FACILITY_NAME
BILLJAR VALERO
STREET_NUMBER
153
Direction
E
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23336607
CURRENT_STATUS
01
SITE_LOCATION
153 E ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TLSw350 Monitoring System Requirements Assist ISD <br /> Part Numer Description Requirement <br /> • TIS-350 with F.CPU2 <br /> 330020.445 Assist Vapor Flow Motor Kit 1 per dispenser <br /> • NVMEM 203 <br /> 330020-515 Wired Vapor Pressure Sensor Kit' <br /> • RS-232 Interface Module for On-site PC report access <br /> 861190-201 nriv Wireless Vapor Pressure Sensor Kit' 1 per site <br /> • Smart Sensor Module <br /> 330020415 "tv' Vapor Pressure Sensor Site Start-up Kit' <br /> • Dispenser hnterface Module (DIM) <br /> • ISD Software Enhancement Module (SEM) 332250.110 Seven Input Smart Sensor Modules i per seven or eight <br /> 329356.004 Eight Input Smart Sensor Module Smart Sensors <br /> • Site Shutdown Control Hardware <br /> Alarm Table Balance ISD <br /> The following table contains a list of warnings and alarms posted or Part Numer Description Requirement <br /> used by the ISD system: 330020.585 Balance Vapor Flow Meter Kit 1 per dispenser <br /> Balance Assist Warning Days to Description 330020-515 Wired Vapor Pressure Sensor Kit' <br /> ISD ISD Alarm <br /> 861190-201 "r`v Wireless Vapor Pressure Sensor Kit' 1 per site <br /> X X ISD DEGRD PRESSURE 30 7511 percentile of days' uliage <br /> pressure that exceeds 0.3 IWC 330020-715 NEW Vapor Pressure SenscrSite Start-up KR' <br /> 95• percentile of 7 days' ullage 332250-001 Seven Input Smart Sensor Modules 1 per seven or eight <br /> X X ISD GROSS PRESSURE 7 pressure that exceeds 1 .3 IWCSmart Sensors <br /> 329356.004 Eight Input Smart Sensor Module <br /> X X ISO VAPOR LEAKAGE 7 Containment system leaks at two 847490-315 PMC Port Controller Module' 1 per TLS Console <br /> times the TP 2013 standard <br /> X x ISD SENSOR OUT 7 Failure of Sensor Self-test TLS-350 Software/Memory <br /> X x ISD SETUP 7 Failure of Setup Test Upgrade Options for ISD <br /> X Hnn: DEGRD COLLECT 7 7-day Degradation AA. Test Part Numer Description Requirement <br /> X Han: GROSS COLLECT 1 1 -day Gross A/LTest Warning 331500-358 ECPU2, latestV.3XX software, NVMEM 203 <br /> Vapor collection flow perfomance 331500-322 LatestV.3XX software, NVMEM 203 <br /> X Hnn: FLOW COLLECT 1 is less than 50°b <br /> 332966.203 NVMEM 203 (report storage) 1 per Console <br /> X ISD VP PRESSURE 1 901h percentile of 1 -day uliage 330160.004 ISD Software Enhancement Module (SEM) <br /> pressure exceeds 2.5 IWC <br /> 331500-353 TLS V3XX software <br /> X ISD VP EMISSIONS 1 Mass emission exceeded the <br /> certified threshold <br /> Failure of Vapor Processor Effluent Optional ISD Components <br /> X ISDVP Status 1 Emissions or Duty Cycle Test <br /> Part Numer Description Requirement <br /> 331408.001 Dispenser Control Module for Single 1 module per <br /> Dispenser Shutdown 4 dispensers <br /> Typical ISD Configuration <br /> i Vapor Pressure Sensor KR for Mounting <br /> Carbon Canister 330020 630 on Vent Stack' i per Console <br /> 1 r <br /> i 1 per Pressure Sensor <br /> r 330020-716 Universal Enclosure Box when mounted on <br /> Dispenser Island j Vent Stack <br /> 1 <br /> i 330020-717 "r'y Vapor Pressure Sensor Drying Tube Kit Replacement Part <br /> III Iso r 1 <br /> TLS Console Pressure <br /> °"� Sensor 1 1 . Can only be used on wired installations. <br /> Ali w/enclosure 2. Can Doty be used on wireless installations. <br /> p (Installation <br /> t 3. Required when ordering 861190-201 sensor for wireless installations. <br /> ISD Option 2) i 4. Only required for VST Vapor Processors. <br /> U t t r Wired or <br /> Flowmeter 5. At least one seven channel module required when installing Carbon Canister Vapor <br /> r t <br /> I <br /> Wireless t Polisher, optional on all other ISD sites. <br /> ISD Pressure Sensor <br /> (Installation Option t) <br /> wlma Only To learn more , contact us at 888 . 561 . 7942 , or visit www.veeder.com . <br /> VEGDGR~ R®® 1 125 Powder Forest Drive, P.O. Box 2003 , Simsbury, CT 06070 USA <br /> 02013 Vccder-Root Company • 576047 065 Rei! F + Primed in USA <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.