Laserfiche WebLink
Advanced Protection Submersible Turbine Pumps <br /> a <br /> ISTAPMVS4-VL7 4 hp AP variable speed with MagShojlTM 64"-92° <br /> ISTAPMVS4 VL2 '4 hp AP variable speed with MagShellT^" X95" 156" <br /> ISTAPMVS4 VL3 4 hp AP variable speed with MagShell7m 127" 218" <br /> ISTAPM 1 2 hp AP variable speed with MagSheljW 59" 87 <br /> ISTAPM 2 2 hp AP variable speed with MagSheljW 90" 151 " <br /> ISTAPM-3 2 hp AP variable speed with MagSheli'm 722=213° <br /> STPAPM200-VL1 2 no AP fixed speed with MagShel W 631-91 ° <br /> STPAPM200-VL2 t2 hp AP fixed speed with MagShellTm ': 94°-154° <br /> STPAPM200 VL3 2 hp AP fixed speed with MagShellTM 1260-21T <br /> STPAPHM200-VL1 2 hp AP high pressure fixed speed with MagShell[W 630-92" <br /> STPAPHM200-VL2 2 hp AP high pressure fixed speed with MagShelFM 941_16V <br /> STPAPHM200-VL3 2 hp AP high pressure fixed speed with MagShelfrm 126°-218 <br /> STPAP150-VL1 1-1/2 hp AP fixed speed 60u-880 <br /> STPAP160 VL2 1-1/2 hp AP fixed speed 1:91 ° 152" <br /> STPAP150-VL3 1-1/2 hp AP fixed speed 123 214 <br /> STPAPH150-VL1 1-1/2 hp AP high pressure fixed speed 61 -89" <br /> STPAPH150-VL2 1-1/2 hp AP high pressure fixed speed 92 152" <br /> STPAPH150-VL3 1-1/2 hp AP high pressure fixed speed ', 124`-215" <br /> STPAP75-VL1 3/4 hp AP fixed speed 57" 86 <br /> ir <br /> STPAP75 VL2 3/4 hp AP fixed speed ; 88"-149" <br /> STPAP75-VL3 3/4 hp AP fixed speed 120"-212" <br /> Notes: <br /> 1. Remove " M " from model number for non-MagSheliTM pump motor assembly (where applicable). <br /> 2. STPAP/ISTAP models are listed for compatibility with fuel mixtures containing diesel fuel with up to 20% biodiesel, 100% <br /> biodiesel, up to 85% ethanol with gasoline, and 20% MTBE, 20% ETBE or 17% TAME with gasoline. <br /> 3, All models are supplied with a standard check valve unless factory option " R " or "W" is specified. <br /> 4. All above ISTAP models can only be powered by a MagVFCTM, 4 hp models require three-phase incoming power supply, <br /> 2 hp models can be supplied with single- or three-phase incoming power. <br /> 5. All above STPAP models require single-phase, 208-230 VAC, 60 Hz incoming power. <br /> 6 4". riser pipe, if supplied locally, must be 4H` OD by 3/16" Wi tubing. <br /> 7 For riser pipe lengths 310to 60", adder charge applies. <br /> *Model length (A) defined as the dimension from the turbine manifold bottom to the pump motor inlet. ', <br /> Factory Installed Options <br /> ' ..Specified in model number at time of STP order. <br /> ' F Floating suction adapter, 11/2' NPT female, must be factory installed <br /> K WS (intake filter screen) factory. assembled to pump motor assembly <br /> 'R Model R check valve, factory installed, for Veeder-Rootf' PLLD Line Leak <br /> W Model W check valve, factory installed, for Red Jacket PPM4000 Line Leak <br />