S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUNT <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> MARCH LANE 76* 2701 W MARCH LN, STOCKTON December 16, 2021 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2632(d)(1), 2634(d)Failure to have an approved UST Monitoring Plan. <br /> OBSERVATION: The monitoring plan is not approved by the EHD. The following items need to be <br /> addressed/corrected: <br /> -The Tank Overfill Prevention is checked off as"audible/visual alarms"and"fill tube shut-off valve"but the additional <br /> comment section lists that ball floats are used ("Overfill prevention: External A/V alarm set at 90%tank capacity and <br /> ball floats").This additional comment/information does not match what is checked off. (Ball floats were removed <br /> during 11/12/2021 overfill prevention testing). <br /> -For all three tanks Under Dispenser Containment(UDC)Monitoring lists the following incorrect information: <br /> *UDC Panel Manufacturer:Veeder-Root(floats and chains do not have a panel) <br /> *UDC Panel Model:#TLS 350 (floats and chains do not have a panel) <br /> *UDC Leak Sensor Model: Bravo(should be floats and chains) <br /> REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting <br /> System (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> This is a repeat violation, Class II. <br /> 107 HSC 25292.2; CCR 2711(a)(11)Failure to submit and maintain complete and current financial responsibility <br /> documents. <br /> OBSERVATION: Financial responsibility documents have not been submitted to the EHD. The most recent <br /> financial responsibility documents in CERS are dated 12/16/2019. <br /> REGULATION GUIDANCE: Current financial responsibility documents are required to be submitted annually. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS)at <br /> http://cers.calepa.ca.gov/, and upload the required documents. <br /> This is a repeat violation, Class II. <br /> FA0003798 PR0231176 SCO01 12/16/2021 <br /> EHD 23-01 Rev.12/06/2021 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />