Laserfiche WebLink
The following is an itemized list of permit by rule tiered permit violations that have <br /> not been addressed for METAL FINISHING SOLUTIONS - STOCKTON CA as of <br /> April 01 , 2021 . <br /> Open violations from August 31 , 2020 inspection <br /> Title 22 California Code of Regulations section 66265 . 192(k) <br /> The tank system assessment shall include all of the following information : <br /> ( 1 ) tank configuration (i . e . , horizontal , vertical) , material of construction , and gross capacity (in gallons) ; <br /> (2) design standard (s) , if available , according to which the tank and ancillary equipment were or will be constructed <br /> and all of the following information : <br /> (A) material of construction ; <br /> ( B) material thickness and the method used to determine the thickness ; <br /> ( C ) description of tank system piping (material , diameter) ; <br /> ( D) description of any internal and external pumps ; and <br /> ( E) sketch or drawing of tank including dimensions . <br /> (3) documented age of the tank system (if tank was previously used) , if available , (otherwise , an estimate of the <br /> age) ; <br /> (4) description and evaluation of any leak detection equipment; <br /> (5) description and evaluation of any corrosion protection equipment, devices , or material ; <br /> (6) description and evaluation of any spill prevention or overfill equipment; <br /> (7) description and evaluation of secondary containment for the tank system (secondary containment must meet <br /> minimum standards as specified in subsections 0 ) ( 1 ) through 0 )(3) of this section) including applicable secondary <br /> containment for ancillary equipment as required in subsection 66265 . 193(0 ; <br /> (8) hazardous characteristics of the waste(s) that have been or will be handled ; <br /> (9) prior to placing a new tank system or component in use , an independent, qualified installation inspector or an <br /> independent, qualified , professional engineer, registered in California , either of whom is trained and experienced in <br /> the proper installation of tank systems , shall inspect the system or component for the presence of any of the <br /> following items and document in writing the results of the inspection : <br /> (A) weld cracks or breaks ; <br /> ( B ) scrapes of protective coatings ; <br /> ( C ) corrosion ; <br /> ( D) any structural damage or inadequate construction or installation such as cracks , punctures , damaged fittings . All <br /> discrepancies shall be documented in the assessment and remedied before the tank system is placed in use . <br /> ( 10) all new tanks and ancillary equipment shall be tested for tightness prior to being placed in use . The results of <br /> the test(s) shall be documented in this assessment. Tank system integrity or leak test requirements must be in <br /> compliance with all local requirements . Prior to conducting a tank system integrity test or leak test, contact local <br /> agency staff for local requirements . <br /> ( 11 ) estimated remaining service life of the tank system based on findings of subsections (k) ( 1 ) through (k)( 10) . <br /> Title 22 California Code of Regulations section 66265 . 1920) <br /> ( 1 ) tank system must have secondary containment capable of containing 100 percent of the contents of the tank <br /> and ancillary piping volume ; and <br /> (2) if the tank system is exposed to precipitation , the secondary containment system must have sufficient capacity, <br /> in addition to that required in subsection 0 ) ( 1 ) of this section , to contain run-on and infiltration from a 25-year, <br /> 24-hour rainfall event; <br /> (3) tank system secondary containment shall be provided with a leak detection system that is designed and <br /> operated so that it will detect either the failure of the primary and secondary containment structure or any release of <br /> hazardous waste or accumulated liquid in the secondary containment system within 24 hours , or at the earliest <br /> practicable time if the existing detection technology or site conditions will not allow detection of a release within 24 <br /> hours . <br /> Title 22 California Code of Regulations section 66265 . 193(f) <br /> (f) Ancillary equipment shall be provided with full secondary containment (e .g . , trench , jacketing , double-walled <br /> piping ) that meets the requirements of subsections (b) and (c) of this section except for: <br /> ( 1 ) aboveground piping (exclusive of flanges , joints , valves , and connections) that are visually inspected for leaks on <br /> a daily basis ; <br /> (2) welded flanges, welded joints , and welded connections that are visually inspected for leaks on a daily basis ; <br /> (3) sealless or magnetic coupling pumps and sealless valves , that are visually inspected for leaks on a daily basis ; <br /> and <br /> Page 3 of 4 <br />