SKIMMER LAYOUT and SUCTION LINE SIZING I STA•R I TE U -3 SKIMMER <br /> NOTICE: Installation must comply with all applicable codes, <br /> including NSF Standard 50 (if required). Equalizer lines may be o INSTALLATION, OPERATION & PARTS <br /> required on public pool or commecrical pool installations. I --———— o . <br /> I I I p <br /> 1. Use one skimmer per 500 square feet of pool surface area, l i I Save these instructions. Carefully read and follow all safety instructions in this manual. - <br /> Suction line sizes are based on a water velocity of less than . <br /> seven feet per second.Since building codes vary,check your _ _; Pool water level: Keep pool water level at least 1-1/2 to 2"above <br /> local building code before installing pool and skimmers. 18" 1- - 18 A 1NARNtNG Hazardous Suction, bottom of skimmer opening for proper operation. <br /> -" Risk of hair or body 2. Suction line sizes for each section of piping must allow for �_;_f o -. Ref y Float Valve: Float valve protects pump from loss of prime if <br /> the total number of skimmers feeding that section of the line. I 1, entrapment, drowning or skimmer clogs or flow through skimmer is restricted. Trimmer <br /> Suction line sizing in Chart I allows for this. i disembowelment. valve plate on bottom of float valve balances flow between <br /> l Wall fitting on equalizer line <br /> 3. See Figures 5 and 7 Pages 2 and 3, for piping layout. See ♦ skimmer and main drain. <br /> g � g P P g Y � must be non-entrapping of <br /> Chart I, Page 3, for suction pipe sizing. ; rI hair or body at flow rates up Flow adjustment: Balance flow between skimmer and main <br /> 4. For good hydraulic balance, divide skimmers as equally as d I to 55 GPM. drain. <br /> possible between the main branches of the piping layout. 1"Vertical Plan View I A.Skimmers without float:Adjust shut-off valves in pump suc- <br /> 5. For long pipe runs (in which friction can reduce flow and adjustment A CAUTION tion line from skimmer and pool main drain line. (See <br /> Blocking pump suction can cause pressure Figure 1, below.) <br /> pressure), refer to your friction/flow chart for proper pipe of frame to 27" surges and water hammer, which can damage um orpipingg <br /> sizes. accommodate 11'/4 Ref $ 8 pump B. Skimmers with float: If skimmer is equipped with float <br /> misalignment. 71/1 and may cause flooding. valve, adjust trimmer plate on bottom of float. To reach <br /> 6. When planning location of skimmers on one-and two-skim- 1" trimmer plate, remove cover, basket, and float valve (See <br /> mer outdoor pools, locate skimmers so that the prevailing OPERATION Figure 2, below). Swing trimmer plate to one side to <br /> wind blows into the skimmers. 44'% increase trimmer port size(more flow through skimmer, less <br /> INSTALLATION All Models: flow through main drain); reduce port size for less flow <br /> To Pump through skimmer and more flow through main drain. <br /> Concrete: See Figure 7 for basic dimensions. Top cover frame Suction Pump suction pulls water through skimmer. Water flow intoskimmer carries floatin leaves, bus etc., into skimmer where Sweeping pool: For installation without equalizer line, hold <br /> has 1" vertical height adjustment, g bugs, <br /> they are trapped in skimmer basket. (Dust, body oils,etc.,go on <br /> NOTICE: Skimmer MUST be surrounded by at least 4" of pool weir up to starve skimmer of water and close float valve. This <br /> directs all flow through main drain. To return to normal skim- <br /> structure concrete in a monolithic our, usingcold joint as through to be removed by pool filter.) Floating weir in skimmer <br /> P � a co1 opening enhances surface flow and skimming action. Model ming operation, turn pump off 10-15 seconds, allowing skim- <br /> shown in installation drawings. 26" I v mer to fill and float valve to return to open position. Skimmer <br /> 1404 and 2404 are NSF listed.. <br /> Line Connections and Testing: Connect pump inlet line to rear Series 1403,i will now operate normally as long as pool water level is high <br /> port in bottom manifold(Figure 7).Skimmer is ABS plastic;man- - enough to allow normal flow over weir. <br /> ifold connections are 1-1/2 or 2" threaded or 1-1/2" slip. For <br /> threaded connections, do not use pipe dope; la seal joint use - - - - Typical Public Pool Skimmer Installation with Equalizer Line Installed <br /> RTV Silastic#732* (preferred),teflon tape, or Plasto-Joint Stik**. ° P� e Yp � <br /> For slip connections, apply PVC primer to PVC pipe only. Then � �" <br /> apply ABS to PVC solvent cement to both pipe and slip connec- Alternate / Equalizer F Pool Vacuum <br /> 4° ` Hose <br /> tions. Consult dealer for correct solvent cement for pipe used. Line from Via:l; t2l: <br /> Section View <br /> Main Drain. <br /> Assemble Dint per cement manufacturers instructions.Allow at <br /> j P <br /> least 3 hours before pressure testing. .: rA:.M <br /> < »:. ...a a [ .i,"tl•" " 3 °iiEE �`'•-ae. .:.''^•.,,, a NdCp Um <br /> AWARNING <br /> Plastic cements and primers can he flammable, ri ;;;: °° � �" °r:", ".i s�; r'.� °..°:�°.a�P"•Plate <br /> � .: ;�" .. {;� w,�n ill ilia;•a! _:::?, '`:, " "�.....°.,°i.;; <br /> Poisonous or both. Closelyfollow cement manufacturer's — :• E�:< m :; iii 3� <br /> anuurers � Float )"�e',."I gg - 6-a? `,"..< hp- •®�e.F:i. <br /> Float <br /> instructions when using plastic cement. Valve �9, ,i° <br /> ° �I;, n <br /> Flow Open Valve <br /> Through No Flow Shut <br /> In residential installations where equalizers are not required Over check - <br /> q q Skimmer . <br /> �e weir Valve <br /> and where the main drain line does not connect to the skimmer `----� open �s. " Removeel,eck�' - <br /> �__.• <br /> e ualizer ort, low water levels in the Dol or clo ed skimmer Check To Pum Valve;Flu ,.< <br /> q P P gg —r P To Pump la 1 <br /> 111 :=-e <br /> Valve ° Equalizer(or <br /> Suction Suction To Pum <br /> baskets may damage the pump due to loss of prime (if skimmer „ li shut From ):: s Main Drain) §3' e 3 Suction <br /> p <br /> - -_-_ : Equalizer Port <br /> sucks air)or cavitation (if skimmer clogs).Air pulled in by skim- kt;>i�t s9ee; <br /> II II 1� li Equalizer outlet <br /> Line bm "� ,;..,i» Equalizer <br /> marts?can be trapped in filter tanks,which may be a safety hoz- Use 8011-Series anti-entra in "` t� <br /> PP g .' ,�- - ."° ;;i,�.: <br /> ard. 1f skimmer regularly vortexes or sucks air, raise pool water - -: `�ns`s Sg;° •1 r•'' 10224594 •-'•" 4° 'J- <br /> g y p 55 GPM equalizer fitting with �� - - � °`_° <br /> f =:g S B:• - 10210594 <br /> level or contact your pool service representative for advice. 8010 Series Cover or use 8012 <br /> Series Cover on 8429 Wall Fitting. <br /> Cover must fit tight to fitting to ( Figure 1: Normal operation: float Figure 2: Equalizer operation; float Figure 3: Vacuuming pool; float and <br /> Dow Corning prevent entrapment. <br /> -Lake Chemical Co.,Chicago,IL —— I� — I� valve open, check valve shut. valve shut,.check valve open. check valves removed, equalizer (check <br /> valve) port plugged. <br /> Front View Sta-Rite Pool/Spa Group <br /> 293 Wright Street, Delavan, WI 53115 <br /> Figure 8- U-3 Skimmer Installation North America:800-752-0183,FAX 800-582-2217 <br /> International:414-728-5551,FAX:414-728-4461,TELEX:ITT 4970245 <br /> Drawings and Specifications Oxnard,CA-Union City,TN-Delavan,WI-Mississauga,opt. <br /> 01997,Sta-Rite Industries,Inc. Printed in U.S.A. 39501-0028(Rev.11112/97) <br />