Laserfiche WebLink
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for ONE STOP MARKET* as of September 15 , 2021 . <br /> Open violations from December 15 , 2020 inspection <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #205 - Failure to have current UST Monitoring Plan readily accessible at the facility. <br /> OBSERVATION : An approved copy of the monitoring plans were not available for inspection . <br /> REGULATION GUIDANCE : A copy of these plans shall be accessible on site at all times . <br /> CORRECTIVE ACTION : Immediately locate and retain a copy on site . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #208 - Failure to comply with the designated operator inspection requirements . <br /> OBSERVATION : The designated operator failed to document all the alarms from the attached alarm history on the <br /> 10/26/2020 designated operator inspection report and failed to check that they were responded to appropriately . <br /> The missing alarms include: L1 Disp1 -2 fuel alarm of 10/ 15/2020 , L2 Disp3-4 fuel alarm of 10/15/2020, L3 Disp5-6 <br /> fuel alarm of 10/ 15/2020 , L4 Disp7-8 fuel alarm of 10/15/2020 , L5 87 STP sump fuel alarm of 10/15/2020 , L6 Diesel <br /> STP sump fuel alarm of 10/15/2020 . L7 91 STP sump fuel alarm , L8 87 Annular apace fuel alarm Of 10/15/2020 , L9 <br /> diesel annular space fuel alarm of 10/ 15/2020 , and L10 91annular space fuel alarm of 10/15/2020 <br /> REGULATION GUIDANCE : During the inspection , the designated operator shall review the alarm history since the <br /> previous inspection , check that each alarm was documented and responded to appropriately, and attach a copy of <br /> the alarm history with documentation taken in response to any alarms to the inspection report. <br /> CORRECTIVE ACTION : Ensure that designated operators performing inspections at this facility are including all of <br /> the required information on the reports . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Page 3 of 3 <br />