Laserfiche WebLink
Time In: 11:50 am <br /> Time Out: 12:35 pm <br /> a� N San Joaquin County <br /> Environmental Health Department <br /> N: X <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> c4 �; Telephone: (209) 468-3420 Fax: (209) 464-0138 Web:www.sjgov.org/ehd <br /> Swimming Pool Service Request Inspection Report <br /> Name of Facility: JOHN WILSON POOL Date: 07/20/2016 <br /> Address: 900 W LOWELL AVE, TRACY 95376 <br /> Requestor: JOHN COURTNEY, RJM DESIGN GROUP Telephone: (916) 361-9010 <br /> Program Element: 3601 - NEW POOUSPA PLAN CHECK Request#: SR0071428 <br /> Inspection Type: 523 - Plan Check/Report Review <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #3 Safety Signs <br /> OBSERVATIONS: Provide keep gate closed at all gate. Provide by today. Note: lifeguards provided when pool is open. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained.(CCR 65535) Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole, gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #36 Pressure and Vacuum Gauges <br /> OBSERVATIONS: Install a vacuum gauge on the recirculation pump prior to opening the water feature <br /> CALCODE DESCRIPTION:Pressure and vacuum gauges shall be provided for each pump system. (CBC 3125B) <br /> #42 Spray Ground Recirculation System <br /> OBSERVATIONS: Flow rate is 126 gpm. It requires 140 gpm. The pump is 2 hp. Plans called for 3 hp. It appears the pumps <br /> were switched between the booster and the circulation pumps. Correct prior to operating. <br /> CALCODE DESCRIPTION:Recirculation system shall be in operation at all times the spray ground is open for use and shall have a <br /> minimum of 4 turnovers prior to opening. (CBC 3106B) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 126 gpm Chlorine: 5 ppm Temp: ° F <br /> Cyanuric acid: 0 ppm pH: 7.6 Combined chlorine: 0 ppm <br /> NOTES <br /> Filter Sand 9.6 sqft, 192 gpm <br /> recirc Pump 2hp <br /> jets pump 3hp <br /> tank 4194 gal <br /> Influent 6 psi <br /> psi at jets 30 <br /> FA0003236 SR0071428 SC523 07/20/2016 <br /> EHD 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool Service Request Inspection Report <br />