My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2022 4:34:32 PM
Creation date
1/19/2021 8:57:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Monitoring System Certification Form <br />7. LINE LEAK DETECTOR TESTING <br />❑✓ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) <br />Simulated release rate verified: (Check all that apply.) Yes No NA <br />❑ 3 GFH ❑ 0.1 GPH ❑ 0.2 GPH <br />Has the testing apparatus been properly calibrated? ❑ ❑ ❑ <br />For emergency generator tank systems, does the LLD create an audible and visual ❑ ❑ ❑ <br />alarm when a leak is detected? <br />For mechanical LLDs, does the LLD restrict the flow through the pipe when a ❑ ❑ ❑ <br />release is detected? <br />For electronic LLDs, does the turbine automatically shut off when a release is ❑ ❑ ❑ <br />detected? <br />For electronic LLDs, does the turbine automatically shut off if any portion of the ❑ ❑ ❑ <br />monitorings stem is disabled or disconnected? <br />For electronic LLDs, does the turbine automatically shut off if any portion of the ❑ ❑ ❑ <br />monitoring system malfunctions or fails a tightness test? <br />For electronic LLDs, have all accessible wiring connections been visually inspected ❑ ❑ ❑ <br />for kinks and breaks? <br />Were all items on the equipment manufacturer's maintenance checklist completed? ❑ ❑ ❑ <br />Were all LLDs confirmed operational within regulatory requirements? ❑ ❑ ❑ <br />Describe all answers marked "No" or "Fail" and proposed remedy in Section 9. <br />List all monitoring equipment either replaced or repaired in Section 9 <br />Page 4 of 6 <br />LLD ID <br />LLD Model <br />Lines Monitored <br />Pass <br />Fail <br />N/A <br />N/A <br />N/A <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />Describe all answers marked "No" or "Fail" and proposed remedy in Section 9. <br />List all monitoring equipment either replaced or repaired in Section 9 <br />Page 4 of 6 <br />