My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/3/2022 4:34:32 PM
Creation date
1/19/2021 8:57:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TAI T <br />IMMO TO T [X�IIrXGr <br />p:714/560/8222 wwlv.tait.com <br />701 N. Parkcenter Drive, Santa Ana, CA 92705 <br />Identification of Test Procedures for Secondary Containment Testing <br />To Whom It May Concern: <br />Tait Environmental Services, Inc., utilizes the following procedures when conducting Secondary <br />Containment Testing: <br />1) Containment Sumps, Transition Sumps, UDCs —Tait follows PEI-RP1200-17 Section 6.6 for the <br />accelerated test method. Tait uses the Incon TS4000 hydrostatic test equipment following the <br />attached procedures. <br />2) Spill Buckets; Direct Bury & Contained in Sumps — Spill buckets contained in sumps are tested <br />per PEI -120047, Section 6.2, however Tait Pass/Fail threshold is 0" drop in one hour. Direct Bury <br />Spill Buckets are test the same as containment sumps per PEI -120047, Section 6.6. <br />3) Tank Annular Space — testing is conducted per PEI -1200-17, Section 4.2 <br />4) Piping Secondary Containment — Testing is conducted per PEI-RP1200-17, Section 5.3 <br />Please consider this letter as our Test Procedure utilized when conducting Secondary Containment <br />Testing in lieu of either parts or the whole RP1200 document due to copyright infringement. <br />
The URL can be used to link to this page
Your browser does not support the video tag.