Laserfiche WebLink
S0 JOA U 1 Environmental Health Department <br /> u ;� i YI AMENDED <br /> 3/18/2021 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SAFEWAY FUEL CENTER#1769 2802 COUNTRY CLUB BLVD, STOCKTON March 16, 2021 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 202 CCR 2712(i) Failure to retain a paper or electronic copy of the permit to operate at the facility. <br /> OBSERVATION:A copy of the UST operating permit was not found on site. <br /> REGULATION GUIDANCE:A copy of the UST operating permit and all attachments and conditions shall be <br /> retained at the facility. <br /> CORRECTIVE ACTION: This violation was corrected on site. The EHD provided a copy of the operating permit at <br /> the time of the inspection. It was printed and made available on site. No further action needed. <br /> This is a Class II violation. <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. <br /> OBSERVATION: The owner/operator failed to document follow-up action to the compliance issues listed for the <br /> following reports: 03/03/2020, 03/31/2020, 04/29/2020, 07/20/2020, 08/17/2020, 09/14/2020, 12/08/2020, and <br /> 01/05/2021. <br /> REGULATORY GUIDANCE:Within 48 hours of the completion of the designated UST operator visual inspection, <br /> the designated operator shall sign and provide the owner or operator with a copy of the inspection report. Within 72 <br /> hours of being provided a signed copy of the report,the owner or operator shall provide a description of each <br /> corrective action taken or to be taken and shall sign and date the report, acknowledging the identified compliance <br /> issues. <br /> CORRECTIVE ACTION: Ensure all designated operator inspection reports are completed and signed within the <br /> required time frame in the future. <br /> ----------------------- <br /> ----------------------- <br /> OBSERVATION: The designated operator failed to check and note the correct test dates for the monitoring system <br /> certification on the 08/17/2020, 09/14/2020, 10/12/2020, 11/10/2020, 12/08/2020, and 01/05/2021 designated <br /> operator inspection reports. The monitoring system certification test date was documented as 01/08/2020, <br /> however,the monitoring system certification was conducted on 07/20/2020. <br /> REGULATION GUIDANCE: During the inspection, the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of <br /> the required information on the reports. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> FA0012764 PR0516736 SCO01 03/16/2021 <br /> EHD 23-01 Rev.9/16/2020 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />