My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
NEWCASTLE
>
7650
>
2800 - Aboveground Petroleum Storage Program
>
PR0527758
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/24/2021 8:22:18 AM
Creation date
1/19/2021 3:56:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0527758
PE
2832
FACILITY_ID
FA0003938
FACILITY_NAME
CDCR-NORTHERN CALIFORNIA YOUTH CORRECTIONAL CENTER
STREET_NUMBER
7650
Direction
S
STREET_NAME
NEWCASTLE
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
18115002
CURRENT_STATUS
01
SITE_LOCATION
7650 S NEWCASTLE RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
190
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA DEPARTMENT OF CORRECTIONS AND REHABILITATION <br /> SERVICE REQUEST <br /> CDCR 995(7/05) PAGE 1 OF 1 <br /> INSTRUCTIONS <br /> Whenever any property improvement is made in field construction which costs from $1,000 to $10,000 a complete detailed report may be filed to request <br /> architecture and engineering services, listing the following Items, so that proper construction standards will be adhered to. Submit the following to the Office of <br /> Facilities Management,Day Labor and Professional Services,Attn:Architecture/Engineering <br /> 1. Submit sketches as necessary. <br /> 2. Identify the problem. Indicate what is to be accomplished. <br /> 3. The solution: Describe, in detail,the recommended change or changes that will be made as applicable. <br /> INSTITUTION DATE <br /> Northern California Youth Correctional Center(NCYCC) <br /> PROJECT <br /> Spill Prevention Control and Countermeasure (SPCC) Plan <br /> SITE LOCATION <br /> NCYCC <br /> REFERENCE DATA(Complete as applicable) <br /> SPECIFICATION SECTION NUMBER PAGE NUMBER PARAGRAPH <br /> NUMBER <br /> DRAWING NUMBER ENTITLED <br /> SKETCH NUMBER DATED ENTITLED <br /> DESCRIPTION(Add extra sheets as necessary) <br /> DETAILED IDENTIFICATION OF THE PROBLEM <br /> The Spill Prevention, Control and Countermeasure (SPCC) Plan for the Northern California Youth Correctional j <br /> Center was prepared pursuant to the Environmental Protection Agency (U.S. EPA) regulations on petroleum <br /> pollution prevention, 40 CFR, Part 112 and 761, in order to minimize the potential for petroleum spills, prevent <br /> accidentally spilled petroleum from leaving the property, and to provide maximum efficiency cleanup of spilled <br /> petroleum. The SPCC Plan must be signed and stamped by a licensed Civil/Professional Engineer. <br /> Prior to the review of the SPCC, we are requesting an Engineer review of 3 generator diesel tanks (Delta room, i <br /> Central Kitchen, & OHC Education)to determine if they are doubled-walled tanks. Per regulation guidance, all bulls <br /> storage tanks must be provided with a secondary means of containment for the entire capacity of the tank and <br /> sufficient freeboard to contain precipitation. In addition, the 400 gallon used oil tank contain a liquid level sensing <br /> device. We are requesting an engineer to review and determine/design the placement of a liquid level sensing <br /> device. <br /> DETAILED SOLUTION PROPOSED OR ACCOMPLISHED <br /> Request: <br /> 1. Review generator diesel tanks at the Delta Room, Central Kitchen, & OHC Education to determine <br /> if the tanks are doubled- walled. If not, how can we add secondary containment around the tanks. <br /> 2. Review and design the placement of a liquid level sensing device on the 400 gallon used oil tank. <br /> 3. Review and stamp of NCYCC's SPCC plan. <br /> IS THE PROBLEM AN ISOLATED CASE OR CENTRAL? <br /> ® ISOLATED CASE ❑CENTRAL <br /> SUBMIT SKETCHES AS NECESSARY AND LIST OTHER ATTACHMENTS <br /> SUBMITTED BY: TITLE DATE <br /> Derrick Bowler CPOIII <br /> FACILITY TELEPHONE NUMBER <br /> NCYCC Plant Operations 209) 944-66513 <br />
The URL can be used to link to this page
Your browser does not support the video tag.