My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2022 4:03:29 PM
Creation date
1/20/2021 9:53:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM (Page 1 of 6) <br /> This form must be used to document testing and servicing of underground storage tank(UST)monitoring equipment. A copy of this form <br /> must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local agency regulating the <br /> USTs within 30 days of the date of the monitoring system certification. <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10146151 05/21/20 <br /> Business Name(Same as Facility Name or DBA—Doing Business As.) Building# <br /> Costco#1091 Lodi <br /> Business Site Address City ZIP Code <br /> 2680 Reynolds Ranch Parkway Lodi 95240 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone# <br /> Alltech Petro Inc. (209) 532 - 7320 Ext. <br /> Mailing Address <br /> P.O. Box 4208 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification.) <br /> Chad White <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> Ca 623541/09-1747 8152115 2/13/2022 <br /> Monitoring System Training and Certifications List all applicable certifications. Expiration Date <br /> Veeder-Root ATG Tech #B36877 06/11/21 <br /> Va orless LDT-890 LDT#2126 05/28/20 <br /> OPW#100301 06/19/20 <br /> Phil-Tite #1015593710 05/30/22 <br /> III. RESULTS OF TESTING/SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> E Monitoring System Set-up E Alarm History Report <br /> Was any monitoring equipment replaced? ❑ E ❑ <br /> (If"Yes,"identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) <br /> Was damage,debris,or liquid found inside any secondary containment systems? ❑ E ❑ <br /> (If"Yes,"describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer's specifications? E <br /> (If"No,"describe why in section IV below.) <br /> El El <br /> IV. COMMENTS <br /> If directed to use this section,describe how and when the issues were or will be corrected. <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of <br /> Regulations,title 23, division 3, chapter 16,section 2638 and all information contained herein is true and accurate. Attached to <br /> this certification is information (e.g., manufacturers'checklists, monitoring system set-up, alarm history report,etc.) necessary <br /> to verify that this information and the site plan showing the layout of UST system is complete and accurate. <br /> UST Service Technician Signature <br /> ID=Identification,VPH=Vacuum/Pressure/Hydrostatic,UDC=Under-dispenser containment <br />
The URL can be used to link to this page
Your browser does not support the video tag.