Laserfiche WebLink
HOW TO LOCATE THE POSITION OF THE <br /> 71SO AT 95% TANK CAPACITY Measuring Stick <br /> The length of the upper tube and the placement of <br /> the 71 SO valve body determine the shut-off point. <br /> Following the standard instructions for the OPW <br /> 71 SO will provide for initial shutoff at 95 % . In all <br /> cases , the upper tube length must be a minimum of <br /> 6 - 1 /2" plus the length of the riser pipe . All length <br /> measurements are in inches . Riser Pipe <br /> with Face (A) <br /> INSTRUCTIONS Seal Adaptor To Tank <br /> Top ( LD .) (B) <br /> 1 . ) Find tank capacity ( in gallons) from tank To Tank <br /> calibration chart provided by tank manufacturer. Bottom <br /> 2 . ) Calculate 95% of capacity . <br /> 6- 1 /2" <br /> 3 . ) Locate the 95 % volume number on the tank <br /> calibration chart . <br /> 4 . ) Find the dipstick number (X) which corresponds Figure 1 <br /> to the 95% tank volume . And , find the dipstick <br /> number (Y) which corresponds to the EXAMPLE <br /> 100 %volume . 1 . ) For an Owens-Corning Model G -3 Fiberglass® <br /> Tank Calibration Chart : <br /> 5 . ) Subtract the dipstick number (X) from the tank Tank Capacity - 10 , 000 gal . , nominal 9 ,403 gal . <br /> diameter (Y) to find the upper tube reference NOTE : Use actual capacity only <br /> number (Z) . <br /> (Y) - (X) _ (Z) 2 . ) 95 % of actual tank capacity = 0 . 95 x <br /> = <br /> 6 . ) Subtract 2" from (Z) to find the upper tube depth 9403 gal . 8933 gal . <br /> (C) • 3 . ) The closest number which is less than 8933 gal . <br /> (Z) - 2 = C Is 8910 gal . Choosing the closest number less <br /> than 95% of actual capacity ensures that the <br /> 7 . ) Is C less than 6- 1 /2"? initial shutoff will occur when the tank is no more <br /> than 95% full . <br /> NO Upper tube length is C plus the distance <br /> from the top of the Face Seal Adaptor 4 . ) The calibration chart reading of 8910 gal . <br /> installed on the riser pipe to the inside , top corresponds to a dipstick measurement of 82 " . <br /> lip of the storage (A) . <br /> 5 . ) Dipstick number (X) = 82" <br /> Upper Tube Length = C + (A) Tank diameter (Y) = 92" <br /> (Y) - (X) - (Z) (92 "- 82 = 10") <br /> YES Upper tube length is 6- 1 /2" plus the riser (Z) = 10 It <br /> pipe measurement (A) . <br /> 7 . ) (Z) - 2 " = C ( 10" - 2" = 8") <br /> Upper Tube Length = 6- 1 /2" + (A) C = 8 it <br /> NOTE : You must find the actual tank capacity 7 . ) Is 8" less than 6- 1 /2"? <br /> number that correlates to the 6-1 /2" + (A ) depth <br /> for the station records . This number may also NO Measure the distance from the top of the <br /> be used for the purposes of calibrating an FSA-400 Face Seal Adaptor installed on the <br /> electronic tank level system . riser pipe to the inside , top lip of the storage <br /> tank and obtain measurement (A) . <br /> ® Registered T. M . - Owens Corning Fiberglass Corporation Upper tube length - C + (A) <br /> 64 <br />