Laserfiche WebLink
It is imperative to state that the completed SP001 Formal Inspection does not release the tank <br /> owner from their requirements to complete monthly and annual inspections of the tank system <br /> by a qualified individual familiar with the system components. Contact a petroleum contractor <br /> for additional training if necessary. <br /> 5. Authorized Aboveground Tank System Inspector Certification <br /> eFUEL, LLC. manages a fleet of tanks throughout California. In addition, eFUEL's Fuel <br /> Maintenance Division services factory built fuel tanks and generators. Jon Lorente was an <br /> Inspector with a major City Fire Department prior to coming to work with eFUEL, LLC. as <br /> their Director of Compliance and Safety. In addition to his experience and background as a <br /> Fire Inspector, Jon was certified through the Steel Tank Institute as an Aboveground Tank <br /> Inspector in 2018 and has inspected tanks for Fortune 5 companies in the Bay Area. <br /> sl'h�rrt <br /> r PFA Alm ti,-A ond'I'ankI k,1kwl,r <br /> ct-rtlketJun Pru u ra ni <br /> Bwe t}-0k. <br /> 114W,442f6 <br /> 1 VO.2018 <br /> Nama,Jonathan S.Lorrnm <br /> STI I ns pec to r No:AST.2069 <br /> Exp lres:Novtmber2,2023 <br /> the ptrson to whom this card ha€bcen issued hos mcithc <br /> rcquiranrnts to 1wctmw mo nuihorizcd Aboveground i mok <br /> Sysicm Inspcetw in amordonec with the ST I Stnndord SPW L. <br /> 6. Limitations <br /> This inspection was completed according the STI SP001 standard. All observations made during <br /> the inspection were relevent and current as of the date of the inspection. eFUEL, LLC. does not <br /> warranty or guarantee the future functionality or integrity of the tank system. eFUEL, LLC. <br /> and/or its affiliates are not responsible for any compliance requirements associated with the <br /> tank system, follow up for any current or future regulatory violations, or confirming if the <br /> recommended and required action items noted in the inspection for continued use of the tank <br /> system are completed. eFUEL, LLC. will not be returning to the site for a follow-up inspection to <br /> verify if completed action items were addressed unless contracted to do so. <br /> The maintenance of the tank is critical to its long term life span. This includes maintaining the <br /> external coating on the tank and ensuring the interstitial space is kept clear of liquid. <br /> Regarding the information used to form the report, all observations were noted on external and <br /> observable items, documentation provided to the inspector from the tank owner, contractor <br /> and design engineer's SPCC plan. Additional information unknown at the time of inspection <br /> may, and likely would, alter the recommendations, required actions and observations made <br /> during the inspection. Considerable effort was made to ensure the attached report is thorough <br /> and in accord with like reports in the industry. <br /> eFUEL, LLC 11 <br />