Laserfiche WebLink
SYMBOLS <br /> NORTH ARROW � -+ <br /> ELEVATION MARKER EXITING <br /> 1 OCCUPANCY NOTES <br /> 101.1 DOOR DESIGNATION NOTES: <br /> 46 1. REFER TO NOTATION FLOOR PLAN FOR LOCATION OF FIRE EXTINGUISHERS. <br /> BUILDING SECTION O WINDOW DESIGNATION 47 2. REFER TO POSTED SIGNAGE PLAN FOR LOCATION OF TACTILE EXIT SIGNS. <br /> "AA <br /> REFER T <br /> 3. O POSTED SIGNAGE PLAN FOR ASSISTIVE LIST <br /> I� ENING DEVICES AS REQUIRED, <br /> �- <br /> WALL TYPE <br /> 4. FOR EGRESS, SINGLE DOORS ACCOMMODATE 165 OCCUPANTS AND DOUBLE DOORS <br /> WALL SECTION ACCOMMODATE 330 OCCUPANTS, U.O.N. M�A i WB <br /> A5.1 A _�� <br /> i <br /> DETAIL DESIGNATION Jul, = <br /> I .-.-..... ! -.. .... ' _ A3 _. _USE CATEGORY <br /> 3010 S.F. -- —ROOM AREA ARCHITECTS <br /> 15 SF 20 � --OCCUPANT LOAD <br /> NUMBERED NOTE1 EXIT EXITS REQUIRED <br /> STRUCTURAL1 OCCUPANCY LOAD FACTOR 5757 Pacific Avenue <br /> GRND LINE P1 FINISH bESIGNATION ��"""`�" �' �j � OFFI Suite 226 <br /> 43 t <br /> ® PANIC HARDWAREStockton, CA 95207 <br /> 1� CABINET ELEVATION " <br /> r- <br /> _.._._.....___ _ r <br /> 1 ^^^I o sF I ILLUMINATED EXIT SIGN- <br /> PREP o _1 . ( _ 2000 L Street <br /> REFER TO ELECTRICAL DWGS. <br /> TOILET ACCESSORY 304 5F f Suite '�25 <br /> 2 10.1 3 INTERIOR oasF z 'o <br /> ' Sacramento CA <br /> ELEVATION MARKER 1 zi� 1 � � f � I O <br /> � ,�i ��' BANQUET � � 0 NUMBER OF OCCUPANTS 958'11 <br /> REVISION TO DRAWINGS 326 SF <br /> 4 <br /> 15 sF 22 T 209.944.9 <br /> 110 <br /> _.-___._ 1 <br /> CENTERLINE DESIGNATION _ _ _ _ —W ( �W F 209.94,4.57'11 <br /> ROOM NAME ROOM NAME <br /> WWW.Wm barchitects.com <br /> 70� AND NUMBER BAR _ <br /> ' 290 SF <br /> FOOD <br /> i <br /> 15 SF 20 € PREP <br /> 1 162 SF PROJECT DATA <br /> p �+ ;f 0 SF 1 <br /> -- ABBREVIATIONS E Vii; 1 PROJECT DESCRIPTION RESTAURANT REMODEL <br /> KITCHEN - �0 11L _._. <br /> r <br /> @ AT F.D. FLOOR DRAIN YES NO <br /> P.F. PREFINISHED 513 SF DINING <br /> A.B. ANCHOR BOLT F.E. FIRE EXTINGUISHER P.O.G. POINT OF CONNECTION OOSF 3 <br /> A.C. AIR CONDITIONER 2034 SF FOOD ALTERATION TO EXISTING BUILDING X <br /> F.G. FIBERGLASS 1 FINISH GRADE P.T. PRESSURE TREATED 1 <br /> A.D. AREA DRAIN 15 SF 136 PREP <br /> F.H. FIRE HYDRANT PL, PLATE 2 343 SF ADDITION TO EXISTING BUILDING <br /> A.F,F. ABOVE FINISH FLOOR F.O.S. FACE OF STUD PLAS. PLASTIC X <br /> ABV, ABOVE 00 SF z <br /> FIN. FINISH PLY PLYWOOD <br /> ACC. ACCESSIBLE FLR. FLOOR CHANGE OF USE X <br /> PR. PAIR FOOD W <br /> ACST. ACOUSTIC FT. FOOT I FEET PROP. PROPERTY 3 . <br /> ADJ, ADJUSTABLE FTG, FOOTING PSI POUNDS PER SQUARE INCH PREP 1kXISTIMIG FIRE SPRINKLERS X <br /> ALUM. ALUMINUM 3 266 SF I <br /> H <br /> APPL. APPLICABLE G.I. GALVANIZED IRON 00 SF z I I _ <br /> R.C. RAIN WATER <br /> COMPACTION 1 I Michael's Pizza <br /> APPROX. APPROXIMATE G.L.B. GLUE LAMINATED BEAM R.W.L. RAIN WATER LEADER <br /> GA. GAUGE R.W.S. RECESSED WATER SERVICE �~ Remodel <br /> TYPE OF CONSTRUCTION III <br /> B.O. BOTTOM OF GD. GRADE RDWD. REDWOOD _ <br /> 2300 W Alpine Ave <br /> B.P. BUILDING PAPER GL. GLASS REfNF. REINFORCED � �.__, OCCUPANCY GROUP A-2 <br /> B.U. BUILT UP GYP. BD. GYPSUM BOARD REQ'D. REQUIRED Stockton, CA 95204 <br /> BD. BOARD RM. ROOM BUILDING AREA <br /> 5980 S.F. <br /> BLDG. BUILDING H.M. HOLLOW METAL <br /> BILK. BLOCK HD. HEAD I BUILDING HEIGHT S.C. SOLID GORE j T I <br /> E) (UNCHANGED) <br /> BLKG. BLOCKING HDR. HEADER <br /> S.D. STORM DRAIN - �a. <br /> BOTT, BOTTOM <br /> HDWR. HARDWARE S.F. SQUARE FOOTAGENUMBER OF STORIESBTWN. BETINI=EN HORIZ. HORIZONTAL S.M. SHEET METALOCCUPANCY PLANHR. HOUR S.M.S. SHEET METAL SCREWr AREA OF WORK F. SYMBOLS / <br /> CAST IRON HT. HEIGHT S.P. SINGLE PLY W <br /> C.I.P. CAST-IN-PLACE S.S. SANITARY SEWER LINE 1 47 ABBREVIATIONS <br /> C,J. CONTROL JOINT I.D, INSIDE DIAMETER STANDING SEAM 1 47 OCCUPANCY LOAD <br /> C.L. CENTER LINE INSUI_. INSULATION STAINLESS STEEL <br /> CAB, CABINET INT. INTERIOR SECT. SECTION S.F./PERSON OCC. LOAD TOTAL OCC. <br /> CAT. CATALOG SHT. SHEET <br /> CBC CALIFORNIA BUILDING CODE JB. JAMB SIM. SIMILAR OCCUPANCY PLAN DINING 15 178 <br /> CLG. CEILING JT. JOINT SL. SILL _ <br /> 189 <br /> LR. CLEAR SPEC. SPECIFICATION SCALE: 118" = 1'-0" - WORK+ANCILLARY AREAS 200 11 <br /> CMU CONCRETE MASONRY UNIT LAM, LAMINATE SQ. SQUARE <br /> COL. COLUMN LAV. LAVATORY STD. STANDARD REQUIRED EXITS 2 <br /> COMP. COMPACTED LT. LIGHT STL. STEEL <br /> CONC. CONCRETE LTWT. LIGHT WEIGHT SUSP. SUSPENDED PROVIDED EXITS 5 <br /> CONT. CONTINUOUS SW. SWITCH <br /> M.L. METAL LATH U ARCM <br /> d PENNY MAX. MAXIMUM T&B TOP&BOTTOMD. <br /> F. DOUGLAS FIR 1 DRINKING MFG. MANUFACTURER T&G TONGUE&GROOVE A. <br /> FOUNTAIN MIN. MINIMUM 1 MINUTE T.O. TOP OF <br /> Q.H. DOUBLE HUNG MTD. MOUNTED T.O.C. TOP OF CURB <br /> D.S. DOWNSPOUT T.O.P. TOP OF PAVING <br /> N0. C 3085 <br /> -:7= <br /> DOUBLE (N) NEW T.S. TUBE STEEL REN. 3-31-21� � <br /> DIA. DIAMETER N.I.C. NOT IN CONTRACT TEMP TEMPORARY <br /> DN. DOWN N.T.S. NOT TO SCALE TYP, TYPICAL �OP <br /> DWG. DRAWING NIA NOT APPLICABLE PLUMBING FIXTURE COUNT CPC TABLE 4 <br /> 22. 1 ) <br /> E.LF.S. EXTERIOR INSULATION & NO./# NUMBER U.B.C. UNIFORM BUILDING CODE FJ U.O.N. UNLESS OTHERWISE NOTED OCCUPANCY S <br /> S.F. . PERSON #PERSONS #MENIWOMEN <br /> FINISH SYSTEM O.C. ON CENTER W.C. URINALS LAVs DRINKING FOUNTAINS SERVICE SINK <br /> E.J. EXPANSION JOINT PUBLISH HISTORY: <br /> O.D. OUTSIDE DIAMETER V.B. VAPOR BARRIER __ REQ'D PROVIDED REQ'D PROVIDED REQ'D�PRDVIDED REQ'D PROVIDED REQ'D PROVIDED <br /> E.W. EACH WAY OPP. OPPOSITE HAND VI.F. VERIFY IN FIELD A-2 DINING 2650 30 89 --�- No. DATE PURPOSE <br /> EA. EACH 104 MEN 52 1 1 1 2� 1 2 <br /> ovl OVER V.T.R. VENT THROUGH ROOF A-2 KITCHENISTORAGE 2911 2Q0 15 0 Q 1 1 08.21.20 PERMIT APPLICATION <br /> EQ. ELEVATION OZ, OUNCE VERT. VERTICAL WOMEN 52 3 3 1 1 <br /> EQ. EQUAL <br /> EXIST.1 EXISTING <br /> (E) W.H. WATER HEATER <br /> EXP. EXPANSION W.I. WROUGHT IRON <br /> EXT. EXTERIOR W.W.F. WOVEN WIRE FABRIC <br /> WI WITH <br /> W/o WITHOUT <br /> WAINS. WAINSCOT <br /> WD. WOOD <br /> GENERAL NOTES <br /> 1. ALL WORK SHALL BE IN CONFORMANCE WITH THE LATEST ADOPTED AND EFFECTIVE EDITION OF TITLE 24, <br /> CALIFORNIA CODE OF REGULATIONS (CCR),AS APPLICABLE: <br /> PART 1 CALIFORNIA ADMINISTRATIVE CODE <br /> PART 2 2019 CALIFORNIA BUILDING CODE <br /> PART 3 2019 CALIFORNIA ELECTRICAL CODE <br /> PART 4 2019 CALIFORNIA MECHANICAL CODE <br /> PART 5 2019 CALIFORNIA PLUMBING CODE <br /> PART 6 2019 CALIFORNIA ENERGY CODE <br /> PART 9 2019 CALIFORNIA FIRE CODE <br /> PART 11 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE <br /> WMB PROJECT: <br /> 2. ASBESTOS CONTAINING MATERIALS MAY BE PRESENT ON SITE OR IN THE EXISTING BUILDING <br /> CONSTRUCTION. IF SUSPECT MATERIALS ARE ENCOUNTERED, THE CONTRACTOR SHALL IMMEDIATELY <br /> 20-030 <br /> NOTIFY THE OWNER'S REPRESENTATIVE FOR INSTRUCTIONS PRIOR TO PROCEEDING WITH ADDITIONAL <br /> WORK, THE CONTRACTOR SHALL IMMEDIATELY POST NOTICES AND TAKE THE PRECAUTIONS <br /> NECESSARY TO ENSURE THE HEALTH AND SAFETY OF ALL WORKERS, THE STAFF AND THE PUBLIC. <br /> T2. 1 <br /> 8121/2020 10:00:11 AM Copyright WMB,Inc. <br />