Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> FDESIGNAITED UNDERGROUND STORAGE TANK OPERATOR VISUAL. INSPECTION REPORT(Page 2 of 2) <br /> VII. INSPECTION HISTORY <br /> w-up action of Section III from the previous inspection been completed appropriately? Y I N <br /> Attach documentation verifying appropriate service to this report $j ❑ <br /> VIII. ALARM HISTORY <br /> Attach a copy o1 the alarm history reportliog to this report. Y N NA <br /> Is the monitoring system powered on and in proper operating mode? ® ❑ ❑ <br /> Has each leak detection alarm since the previous inspection been responded to appropriately? JO ❑ ❑ <br /> Attach documentation verifying appropriate service to this report. <br /> Have all containment sumps that have had a leak detection alarm since the previous inspection been responded to by a ❑ ❑ <br /> qualified UST Service Technician? <br /> List below In Section IX aff containment sumps that have had a leak detection alarm since the previous inspection and have not been <br /> responded to by a qualified UST Service Technician.Containment sumps listed below require a visual inspection for damage,water,debris, <br /> hazardous substance and proper sensor location. The results of the visual ins tion must be recorded in Section IX. <br /> IX. UNDERGROUND STORAGE TANK SYSTEM INSPECTION <br /> Is the containment sump free of dams e,water, debris,and hazardous substance? <br /> Containment Sump ID Y j N Containment SuTR ID Y N <br /> ❑ 13 [1 Cl <br /> ❑ ❑ 11 ❑ <br /> ❑ 11 El ❑ <br /> ❑ ❑ ❑ ❑ <br /> Are all sensors in containment sumps inspected located to detect a leak at the earliest opportunity? ❑ ❑ <br /> Is the spill container free of damage, water,debris,and hazardous substance? <br /> Tank ID Spill Bucket-87 C9 I [11.Tank ID Spill Bucket-DIESEL ki ❑ <br /> Tank ID Spill Bucket-91 ❑ Tank ID El <br /> Is the fill pipe free of obstructions? <br /> Tank ID Spill ffucket-157 Tank ID Pt uc e - SEL ❑ <br /> Tank ID Spill Bucket-91 IN ❑ Tank ID ❑ ❑ <br /> Is the fill cap securely on the fill pipe? <br /> Tank ID Spill Bucket-87 ® ❑ Tank ID Spill Bucket-DIESELEl <br /> Tank ID Spill Bucket-91 C1 I ❑ I Tank It] 1 ❑ ❑ <br /> Is the under-dispenser containment free of damaC e,water,debris,and hazardous substance? <br /> Under-Dispenser Containment ID Y I N INAI Under-Dispenser Containment ID Y N N <br /> Dispenser- IM ❑ ❑ ❑ ❑ ❑ <br /> Dispenser-314 6d ❑ ❑ ❑ ❑ ❑ <br /> Dispenser-5/6 99 ❑ ❑ ❑ ❑ ❑ <br /> Dispenser-7/8 is ❑ ❑ ❑ ❑ ❑ <br /> ❑ ❑ ❑ ❑ ❑ ❑ <br /> =[] -D ❑ ❑ ❑ <br /> Are all sensors in under-dispenser containment located to detect a leak at the earliest opportunity? El ❑ ❑ <br /> X. TESTING AND MAINTENANCE Y N NA Date Last <br /> Performed <br /> Has the monitoring system certification been completed within the past 12 months? ❑ 216120 <br /> Has the spill container testing been completed within the past 12 months? 216120 <br /> Has the overfill prevention equipment inspection been completed within the past 36 months? N ❑ ❑ 311311g <br /> Has the secondary containment testing been completed within the past 36 months? ® ❑ ❑ 815120 <br /> Has the tank tightness testing been completed within required timeframes? ❑ ❑ ® NIA <br /> Has the line tightness testing been completed within the required timeframes? ❑ ❑ ® NIA <br /> Other required testing l maintenance was completed within required timeframe. (List test/maintenance items below.) <br /> Test i Maintenance: ❑ ❑ <br /> Test 1 Maintenance: C1 ❑ <br /> Test 1 Maintenance: ❑ ❑ <br /> Test/Maintenance: ❑ ❑ <br /> Test 1 Maintenance: ❑ ❑ <br /> Test 1 Maintenance: ❑ ❑ <br /> XI. FACILITY EMPLOYEE TRAINING Y N <br /> Have all individuals performing facility employee duties received the required facility employee training within the past 12 months? ❑ <br /> I the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> Y=Yes,N =No,NA=Not Applicable,10=Identification 7-11 -35355-09/04/2020 <br />