My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
1625
>
2200 - Hazardous Waste Program
>
PR0545368
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2021 4:30:26 PM
Creation date
2/1/2021 4:09:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0545368
PE
2220
FACILITY_ID
FA0017457
FACILITY_NAME
SUNRISE TRUCKING
STREET_NUMBER
1625
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19810005
CURRENT_STATUS
02
SITE_LOCATION
1625 LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br /> Environmental th Department <br /> ... <br /> I3 <br /> SmallC, Raza c otos` :Ge <br /> nerafor inspect€ole Report <br /> Facility Name: Facility Address: Date: <br /> VAN G TRUCKING INC 1625 LOUISE AVE, LATHROP September 28, 2020 <br /> Labeling and Storage <br /> 609 HSC 25143.2,25143.9 Failed to meet requirements for claimed excluded recyclable materials ❑V u R ❑COS <br /> 610 CCR 66262.34(b and d) HW generator of X100 kg per month exceeded accumulation time limit c V ❑R ci COS <br /> 611 HSC 25200.3.1(b) Failure of laboratory to comply with hazardous waste accumulation area requirements ❑V ❑R ❑COS <br /> ttlyerS21 Waste <br /> 701 CCR 66273.32(a) UW handler failed to notify EPA RA and obtain an EPA ID#prior to accumulating>5000kg of UW ❑V ❑R )COS <br /> 702 CCR 66273.32(c) Electronic device and CRT handler failed to notify DTSC 30 days prior to accepting offsite UW ❑V R ❑COS <br /> 703 CCR 66273.33(a) UW handler failed to store UW batteries in a manner that prevents release to the environment ❑V ❑R c.COS <br /> 704 CCR 66273.33(b) UW handler failed to properly manage universal waste lamps ❑V c R o COS <br /> 705 CCR 66273.33(c) UW handier failed to properly manage mercury containing universal waste r..V c R r:COS <br /> 706 CCR 66273.33.5 UW handler failed to prevent release of universal waste electronic devices,CRTs or CRT glass ❑V R ❑COS <br /> 707 HSC 25201.16(e) Failed to manage UW aerosol cans in a manner that prevents the unauthorized release of waste ❑V R c COS <br /> 708 HSC 25201.16(f) Failed to properly store and label containers of UW aerosol cans ❑V a R o COS <br /> 709 HSC 25201.16(g) Failed to store UW aerosol cans in an accumulation container c V ❑R o COS <br /> 710 HSC 25201.16(h)(4) No written operating procedure for aerosol can processing ❑V u R u,COS <br /> 711 HSC 25201.160) Failed to submit or amend notification for aerosol can processing c:;V c R ❑COS <br /> 712 CCR 66273.34 UW handler(UWH)failed to label universal waste to identify type of universal waste V ❑R o COS <br /> 713 CCR 66273.35 UWH stored UW onsite greater than one year or was unable to demonstrate storage time ❑V o R m COS <br /> 714 CCR 66273.36 UWH failed to train employees and maintain records on UW handling and emergency procedures c.V ❑R -- <br /> 7 <br /> 715 CCR 66273.39 UWH failed to keep complete records of each shipment of universal waste for three years V ❑R r.COS <br /> 716 CCR 66273.40(x)(3)(4) UW handler sending devices/CRTs/CRT glass to foreign destination failed to submit notification o V o R u COS <br /> 717 CCR 66273.32(b) UWH failed to obtain an ID number from DTSC prior to accumulating>5000kg of non-RCRA UW c V R COS <br /> 718 CCR 66273.32(d) Failure of a UW handler to submit a complete annual report to DTSC ❑V R ❑COS <br /> 719 CCR 66273.38 Failed to transfer UW using packaging and shipping papers to an appropriate destination facility V ❑R ❑COS <br /> 720 CCR 66273.8(b), Disposed of UW or failed to transfer UW to an appropriate destination facility V r R COS <br /> 66273.31(a) <br /> s <br /> Mtr� e Recycler <br /> 801 HSC 25211.4 Failure to obtain Certified Appliance Recycler certification(CAR) ❑V o R ❑COS <br /> 802 HSC 25211.2,25211.3 Failure of a CAR to provide docs that materials that require special handling have been removed V _,R u COS <br /> 803 HSC 25212 Failure of a CAR to properly remove and dispose of all materials that require special handling V : R r.COS <br /> Ether Violations <br /> 3010 See below Unlisted Administration/Documentation violation V e R i-,,COS <br /> 3020 See below Unlisted Training violation j V r1 R ❑COS <br /> 3030 See below Unlisted Operations/Maintenance violation n V R r.COS <br /> 3040 See below Unlisted Release/Leaks/Spills violation ciV :;R COS <br /> 3050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V r R ❑COS <br /> FA0017457 PR0545368 SCO01 09/28/2020 <br /> EHD 22-01 Rev.911612020 Page 3 Of 7 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 F 209 464-0138 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.