COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON
>
1329
>
2300 - Underground Storage Tank Program
>
PR0231487
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2021 11:48:48 AM
Creation date
2/3/2021 9:32:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231487
PE
2351
FACILITY_ID
FA0000293
FACILITY_NAME
Pershing Holdings, Inc. DBA Esclon Arco
STREET_NUMBER
1329
STREET_NAME
ESCALON
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22510003
CURRENT_STATUS
01
SITE_LOCATION
1329 Escalon Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN�JOAQUIN Environmental Health Department <br /> COUNTY <br /> rtir Greatness grows here. <br /> OFFICIAL INSPECTION REPORT <br /> FACILITY NAME/TYPE: Pershing Holdings, Inc. DBA Esclon Arco DATE.7/19/2021 <br /> ADDRESS: 1329 ESCalon Ave CITY: Escalon ZIP CODE:95320 <br /> OWNER/OPERATOR: Benny Dhanda TELEPHONE#:209-405-1659 <br /> TYPE OF INSPECTION: ❑ COMPLAINT ❑ CONSULTATION W OTHER PROGRAM 2351RECORD PR0231487 <br /> ELEMENT: ID#: <br /> NATURE OF COMPLAINT/CONSULTATION: <br /> On site to witness the routine overfill prevention equipment inspection. <br /> OBSERVATIONS/COMMENTS: <br /> This facility is using audible-visual alarms set at 90%. <br /> Witnessed testing of the 87 and 91 overfill probes. All failed. <br /> The probes were individually able to set off all overfill alarms, however, the second probe was unable to cause an <br /> external audible and visual alarm while the first alarm was still active. <br /> Service Technician Onsite: Guadalupe Sanchez <br /> ICC: 4/2/2023; VR: 10/5/2021 <br /> CORRECTIVE ACTIONS: <br /> Immediately discontinue deposition of petroleum into this tank until the component is repaired or replaced by a <br /> properly licensed, trained, and certified contractor under permit and inspection of the EHD. If the failed component <br /> can't be replaced immediately, there is a possibility that the 87 and 91 UST system may be red tagged to <br /> prevent fuel inputs. <br /> Submit a copy of the completed "Overfill Prevention Equipment Inspection Report Form"to EHD within 30 days. <br /> CORRECT BY:Immediately <br /> INSPECTED BY:Shewit Woldearegay <br /> RECEIVED BY: : DATE: <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br /> EHD 48-05 Rev.05/21/18 INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.