PLUMBING FIXTURE SCHEDULE <br />MARK <br />MAKE/MODEL <br />TRIM <br />ACCESSORIES <br />WC -1 <br />KOHLER K-3609 <br />1.28 GPF 17' ADA TANK TYPE ELONGATED WATER CLOSET, <br />BENEKE 523 ELONGATED <br />---- HW <br />HOT WATER LINE <br />495-2121-00 POLISHED CHROME HANDLE, BRASSCRAFT KTSRI7FC <br />SEAT, NON LOCKING <br />TD <br />TRENCH DRAIN <br />STOP, B1-12DLF HOSE, WAX RING, RIGHT HAND 12'RI, LOOSE KEY, <br />COVER, RI PER ADA <br />GAS COCK <br />SS <br />COLOR BY ARCHITECT. <br />REQT'S <br />L-1 <br />KOHLER K-2005 <br />WALL HUNG LAVATORY, ZURN Z6915 -XL -F 0.5 GPM WF FAUCET, ZURN <br />RI PER ADA <br />FINISHED FLOOR <br />VITROUS CHINA <br />ZW1017 MIXING VALVE, DEARBORN 760W-1 GRID DRAIN & PVC P -TRAP <br />REQUIREMENTS <br />ABOVE FINISHED FLOOR <br />—SD— <br />BRASSCRAFT KTSRI7FC STOPS & B -16A SUPPLY HOSES PL UMBEX 2002 <br />BFG <br />BELOW FINISHED GRADE <br />—C— <br />P -TRAP & ANGLE STOP INSULATION. COLOR BY ARCHITECT. <br />MV <br />TWV-1 <br />WILKINS (ZURN) <br />TEMPERING HOT WATER VALVE FOR PUBLIC RESTROOMS, 3/4' MNPT, <br />SET AT 120 DEG F MAX <br />WATER CLOSET <br />34-ZW1017M <br />PROVIDE UNIONS ON EACH SIDE OF VALVE, <br />TEMPERATURE <br />HWS -1 <br />REGENCY <br />SEE EQUIPMENT PLAN <br />SEE EQUIPMENT PLAN <br />LAVATORY <br />600HS17SP <br />SANITARY SEWER DROP <br />S <br />MS -1 <br />REGENCY <br />SEE EQUIPMENT PLAN <br />SEE EQUIPMENT PLAN <br />SERVICE/MOP SINK <br />600SM162012 <br />ROOF DRAIN <br />DF <br />AD -1 <br />KARP DSC 214M <br />GRAY PRIMERED ACCESS DOORS - SEE DRAWINGS FOR TYPE OF <br />PAINT TO MATCH <br />FIRE HOSE STANDPIPE <br />CB, DI <br />LOCKING MECHANISM. UNLESS OTHERWISE NOTED, FURNISH DOORS <br />ARCHITECTURAL SURFACES. <br />INVERT ELEVATION <br />(F-- CO <br />WITH SLOTTED 1/4' LOCKS, MIN SIZE IS 12x12. COLOR BY <br />FG <br />FINISH GRADE <br />FLOOR SINK 3" <br />ARCHITECT, <br />WALL CLEAN OUT <br />TP -1 <br />PPP, INC. <br />PROVIDE DU- ACCESSORY WHERE PRIMER IS USED FOR MORE THAN <br />MOUNT IN WALL BEHIND <br />1-1/2" <br />PR -500 PRIME <br />ONE DRAIN. <br />AD -1 WITH SOV. <br />AD <br />RITE <br />®— FD <br />FLOOR DRAIN <br />FD -1 <br />ZURN ZN415 <br />TYPE B STRAINER FLOOR DRAIN, 2' OUTLET, TRAP PRIMER FITTING. <br />FLOOR SINK <br />REF -1 <br />LSP PRODUCTS <br />METAL BOX, WHITE W/1/4' COMPRESSION STOP WITH 1/4 TURN BALL <br />TRAP PRIMER VALVE <br />HDR <br />OB -509T <br />VALVE FOR REFRIGERATOR ICE MAKER, <br />COLD WATER (DROP) (RISER) <br />FS -1 <br />ZURN <br />12x12 SANI-FLOR RECEPTOR W/ALUM DOME STRAINER. MOUNT LIP 1' <br />- <br />MBH <br />Z -1900-P-2-32 <br />AFF, 2. OUTLET. <br />TEMPERED HOT WATER (115' F) <br />IWH-1 <br />TAKAGI 310C <br />SINGLE POINT USE INSTANTANEOUS HOT WATER HEATER, MODEL 310C, <br />- <br />HW <br />HAND WASH STATION <br />8 GPM, 609F RISE, 120V, IA. 190 MBH INPUT, SET LEAVING WATER <br />HIGH PRESSURE GAS(PROPANE) >5PSI <br />HS <br />HOSE STATION <br />TEMP AT 1209E MAX. <br />COMPRESSED AIR <br />ET -1 <br />STATE TW -5 <br />1 GALLON ACCEPTANCE VOLUME. <br />PLUMBING NOTES: <br />ALL WORK SHALL CONFORM TO THE FOLLOWING CODES: <br />2016 CBC <br />2016 CPC <br />2016 CMC <br />2016 CEC <br />CONTRACTOR SHALL KEEP ALL INSTALLATION INSTRUCTIONS FOR PLUMBING FIXTURES, ACCESS DOORS, SEALING MATERIAL, FIRE <br />STOPPING, ETC, ONSITE IN WATERPROOF POUCHES FOR THE INSPECTING AUTHORITY FOR THEIR REVIEW. <br />PLUMBING CONTRACTOR SHALL SUBMIT 7 SETS OF SUBMITTALS FOR REVIEW AND COMMENT BY THE ENGINEER AND ARCHITECT <br />OF RECORD FOR THE FIXTURES LISTED AND THE MATERIAL TO BE USED AND INSTALLED ON THIS PROJECT AND SHALL MAKE <br />THE APPROPRIATE CHANGES AS DIRECTED BY THE ENGINEER AND ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. <br />MATERIALS: <br />COLD AND HOT WATER <br />TYPE 'L' COPPER ABOVE GROUND AND TYPE 'K' BELOW. FURNISH SHUTOFF VALVES WHERE SHOWN, SHUT OFF VALVES <br />SHALL BE BALL TYPE WITH TEFLON SEATS, STAINLESS STEEL BALL, AND DOUBLE O-RING STEM 1/4 TURN, VALVES TO BE <br />RATED FOR WOG SERVICE. PROVIDE DIELECTRIC UNIONS AT ALL DISSIMILAR METAL CONNECTIONS. INSULATE HOT WATER <br />SUPPLY AND RETURN LINES W/1' FIBERGLASS ASJ MEETING THE REQUIREMENTS OF T-24 MANDATORY FEATURES. <br />SCH 40 CPVC BELOW GRADE OUTSIDE, SIZE AS INDICATED ON THE DRAWINGS. CONTRACTOR SHALL COORDINATE HIS WORK <br />WITH OTHER TRADES. CONTRACTOR SHALL DISINFECT WATER LINES PER AWA GUIDELINES AND PROVIDE THREE COPIES FROM <br />AN INDEPENDENT TEST LAB. WATER SHALL BE TESTED FOR WATER BORNE BACTERIUM, SPORIDIUM AND OTHER PATHOGENS AT <br />THE TIME OF OCCUPANCY AND CERTIFY THE SYSTEM PASSED THESE TESTS, <br />TEST WATER LINES AT 1,5 TIMES WORKING PRESSURE FOR LEAKS, NOT TO EXCEED 100 PSIG. HOLD PRESSURE FOR 24 HOURS. <br />SEWER AND RWL'S - ABS PIPE AND FITTINGS ABOVE AND BELOW GRADE, CI PIPE WITH ESCUTCHEONS WHERE PROHIBITED BY <br />CODE AND THE LOCAL JURISDICTION, CLEANOUTS SHALL BE PROVIDED EVERY 100 FT AND AT EACH CHANGE OF DIRECTION <br />GREATER THAT 909. USE OF ABS PIPE IS LIMITED TO BUILDINGS 2 OR LESS STORIES IN HEIGHT AND CANNOT BE USED <br />WITHIN FIRE RATED ASSEMBLIES, ALL SEWER LINES SHALL BE SLOPED AT A MINIMUM OF 1/4' PER 11. <br />VENT LINES - SEE SEWER LINES. <br />HVAC CONDENSATE DRAIN LINES - TYPE 'M' COPPER PIPE AND FITTINGS INSIDE BUILDING AND SCH 40 PVC PIPE OUTSIDE <br />BUILDING. PROVIDE CLEANOUT AT EACH CHANGE OF DIRECTION AND AT COIL CONNECTION. SLOPE LINES AT 1/8' PER 11. <br />TEST SS AND RWL DRAIN LINES PER SECTION 723.1 AND 1106.2.2 RESPECTIVELY. TEST CONDENSATE DRAIN LINES USING <br />SECTION 1106.2.2 <br />GAS <br />5 PSI SERVICE - 2-1/2' AND SMALLER SHALL BE SCH 40 GI SCREWED PIPE AND FITTINGS. 3' AND LARGER SHALL BE SCH <br />40 WELDED PIPE AND FITTINGS. EXPOSED PIPE SHALL BE GALVANIZED. BURIED PIPE SHALL BE COVERED WITH X -TRU COAT. <br />ALL PIPE INSIDE BUILDING SHALL BE WELDED. <br />7' WC SERVICE - SCH 40 GALVANIZED IRON PIPE AND FITTINGS OUTSIDE BUILDING AND SCH 40 BLACK IRON PIPE INSIDE <br />BUILDING. PAINT WHERE EXPOSED TO INTERIOR FINISHES. <br />TEST 7-11" WC GAS AND LPG LINES USING AIR AT 15 PSIG. OBSERVE FOR 24 HOURS FOR LEAKAGE, TEST ALL GAS LINES <br />WITH HIGHER PRESSURES THAN 11" WC AT 1.5 TIMES WORKING PRESSURE, MINIMUM PRESSURE OF 50 PSIG. HOLD TEST FOR 24 <br />HOURS. <br />FIXTURES <br />ROUGH IN ALL ACCESSIBLE FIXTURES PER THE DETAILS FOUND IN CBC CHAPTER 11, THE ARCHITECTURAL DRAWINGS AND LOCAL <br />CODE REQUIREMENTS, NOTIFY ARCHITECT IN WRITING OF CONFLICTS. <br />SUBMITTALS <br />PROVIDE SEVEN SETS OF SUBMITTALS FOR REVIEW. <br />INSTALLATION <br />BRACE ALL PIPE AND DUCT SYSTEMS PER SMACNA SEISMIC RESTRAINT GUIDELINES INCLUDING CHANGES OF DIRECTION AND <br />CHANGES IN ELEVATION OF MORE THAN 10', <br />CPVC INSTALLATION <br />INSTALLATION OF CPVC FOR NEW AND REPLACEMENT SYSTEMS MUST COMPLY WITH THE REQUIREMENTS AS STATED IN CHAPTER <br />6 AND INSTALLATION STANDARDS IAPMO IS -20-2005, ALL PROCEDURES MUST BE FOLLOWED FOR FLUSHING AND WORKER <br />SAFETY MEASURES. INCLUDED ARE THE PENALTIES AS STATED ON CHAPTER 6 (g), ANY CONTRACTOR OR SUBCONTRACTOR <br />FOUND TO HAVE FAILED TO COMPLY WITH THE VENTILATION GLOVE OR FLUSHING REQUIREMENTS OF SECTION 1.2.2 OF <br />APPENDIX I OF THIS CODE, INSTALLATION STANDARDS FOR CPVC SOLVENT CEMENT HOT AND COLD WATER DISTRIBUTION <br />SYSTEMS. IAPMO IS -20-2005 SHALL BE SUBJECT TO THE PENALTIES ON HEALTH AND SAFETY CODE, DIVISION 13, PART 15 <br />CHAPTER 6 SECTION 17995, <br />IN ADDITION IF DURING THE CONDUCT OF ANY BUILDING INSPECTION, THE BUILDING OFFICIAL FINDS THAT THE VENTILATION <br />AND GLOVE REQUIREMENTS OF SECTION 1.2.2 OF APPENDIX I OF THIS CODE, SPECIAL REQUIREMENTS FOR CPVC INSTALLATION <br />WITHIN RESIDENTIAL BUILDINGS ARE BEING VIOLATED, BUILDING OFFICIAL SHALL CITE THE CONTRACTOR OR SUBCONTRACTOR <br />FOR THE VIOLATION UNDER THE CALIFORNIA PLUMBING CODE. <br />PLUMBING LEGEND <br />SYMBOL <br />DESCRIPTION <br />SYMBOL <br />DESCRIPTION <br />--- CW <br />COLD WATER LINE <br />COLD <br />BALL VALVE <= 4", GATE VALVE>4" <br />---- HW <br />HOT WATER LINE <br />—IAF— <br />BALANCING VALVE <br />TD <br />TRENCH DRAIN <br />3" <br />2" <br />GAS COCK <br />SS <br />SANITARY SEWER <br />AC <br />ABOVE CEILING <br />GL <br />GREASE LINE <br />BFFBELOW <br />FINISHED FLOOR <br />— — HV <br />HORIZONTAL VENT <br />AFF <br />ABOVE FINISHED FLOOR <br />—SD— <br />STORM DRAIN LINE <br />BFG <br />BELOW FINISHED GRADE <br />—C— <br />CONDENSATE DRAIN <br />MV <br />MIXING VALVE <br />—MA— <br />MEDICAL/DENTAL AIR <br />WC <br />WATER CLOSET <br />—V— <br />VACUUM <br />UR <br />URINAL <br />V, VR, VTR <br />VENT, VENT RISER, VENT THRU ROOF <br />L <br />LAVATORY <br />—SSD — <br />SANITARY SEWER DROP <br />S <br />SINK <br />RWL <br />RAIN WATER LEADER <br />MS <br />SERVICE/MOP SINK <br />RD <br />ROOF DRAIN <br />DF <br />DRINKING FOUNTAIN <br />AD <br />AREA DRAIN <br />FHS <br />FIRE HOSE STANDPIPE <br />CB, DI <br />CATCH BASIN (DROP INLET) <br />INV <br />INVERT ELEVATION <br />(F-- CO <br />CLEAN OUT <br />FG <br />FINISH GRADE <br />FLOOR SINK 3" <br />II — WCO <br />WALL CLEAN OUT <br />CUT OFF POINT - COP <br />FCO <br />FLOOR CLEAN OUT <br />1-1/2" <br />POINT OF CONNECTION - POC <br />— YCO <br />YARD CLEAN OUT <br />AD <br />ACCESS DOOR - SEE SCHEDULE FOR TYPES <br />®— FD <br />FLOOR DRAIN <br />CI <br />CAST IRON <br />�— FS <br />FLOOR SINK <br />CENTER LINE <br />TP <br />TRAP PRIMER VALVE <br />HDR <br />HEADER <br />CW, D, R — <br />COLD WATER (DROP) (RISER) <br />ON <br />DOWN <br />HW,D,R,RT — <br />HW SUPPLY (DROP) (RISER) (RETURN) <br />MBH <br />THOUSANDS OF BTU PER HOUR <br />THW —T — <br />TEMPERED HOT WATER (115' F) <br />NIPC <br />NOT IN PLUMBING CONTRACT <br />— G, LPG — <br />NATURAL GAS (PROPANE)<5PS1 <br />HW <br />HAND WASH STATION <br />— HPG — <br />HIGH PRESSURE GAS(PROPANE) >5PSI <br />HS <br />HOSE STATION <br />— CA — <br />COMPRESSED AIR <br />HWG <br />HOT WATER GENERATOR <br />HOSE BIBB <br />BV <br />BALL <5", BUTTERFLY >5" VALVE <br />tsov <br />L <br />UNDER PLUMBING CONTRACT <br />—SCW — <br />SOFT COLD WATER LINE <br />SHUT OFF VALVE <br />— SHW — <br />SOFT HOT WATER LINE <br />FIXTURE CONNECTION SCHEDULE <br />PLUMBING <br />SANITARY <br />WATER <br />FIXTURE <br />SEWER <br />VENT <br />COLD <br />HOT <br />WATER CLOSET FV <br />3- <br />2" <br />1" <br />- <br />WATER CLOSET FT <br />3" <br />2" <br />1/2" <br />- <br />URINAL FV <br />2" <br />1-112" <br />3/4" <br />- <br />URINAL FT <br />2" <br />1-1/2" <br />1/2" <br />- <br />LAV <br />2" <br />1-912" <br />1/2" <br />1/2" <br />BAR SINK <br />2" <br />1-112" <br />1/2" <br />1/2" <br />CLASSROOM SINK <br />2" <br />1-1/2" <br />1/2" <br />1/2" <br />KITCHEN SINK <br />2" <br />1-112" <br />1/2" <br />1/2" <br />MOP SINK <br />3" <br />2" <br />3/4" <br />3/4" <br />TRAP PRIMER <br />- <br />- <br />1/2" <br />- <br />FD - 2" <br />2" <br />1-112" <br />- <br />FD - 3" <br />3" <br />2" <br />DD NOT DATRAC <br />FLOOR SINK 2" <br />2" <br />1-1/2" <br />FLOOR SINK 3" <br />3" <br />1-1/2"- <br />SHOWER - RES. <br />2" <br />1-1/2" <br />1/2" <br />1/2" <br />EYEWASH <br />2" <br />1-1/2" <br />1/2" <br />- <br />n <br />GAS SIZING TABLE <br />DEVLELOPED <br />'L' <br />PIPE <br />CFH <br />100' <br />1/2' <br />50 <br />SIZES FROM <br />TABLE 1216.20) <br />3/4' <br />104 <br />2016 CPC <br />1' <br />195 <br />SEE PLUMBING FLOOR <br />1-1/4' <br />400 <br />PLAN FOR SIZE <br />1-1/2' <br />600 <br />6' DRIP LEG <br />2' <br />1160 <br />2-1/2' <br />1840 <br />PLAN FOR SIZES <br />3' <br />3260 <br />DC <br />1 <br />PLUMBING ROOF PLAN <br />SCALE: 114'= 1'-0' <br />PLUMBING ROOF PLAN NOTES NORTH <br />1D POC - CONNECT (N)RTU-4 TO (E)1 -G STUBBED THRU ROOF, <br />3/4'COND FROM RTU -4 W/CCQ, SPILL TO (E)ROOF DRAIN. <br />IWH-1 CW/HW <br />AND GAS <br />PIPING <br />MOUNT 48' <br />AFF <br />3/4' TBP <br />I , <br />= <br />I <br />v INTEGRAL GAS <br />RELIEF - <br />APPROVED CLEANOUT <br />P.0 <br />VALVE AND <br />SPILL TD <br />J <br />FLEX ASSEMBLY <br />MS -1 <br />SEE PLUMBING FLOOR <br />I' H&CW LINES <br />Yy <br />PLAN FOR SIZE <br />TO IWH-1 <br />6' DRIP LEG <br />GAS LINE - SEE <br />a <br />PLAN FOR SIZES <br />LINE SIZE <br />AND RDUTIN <br />IWH-1 PIPING <br />DETAIL <br />5 <br />DETAIL <br />2' <br />P O <br />(E)ROOF TRUSSES <br />- 24" OC <br />FS -1 FOR FLOOR SINKS LOCATED <br />UNDER WORK CABINETS <br />E(�UIPM ENT BASE TO BE <br />A, KCHED AROUND FLOOR <br />SEE PLAN FOR GRATE <br />ARRANGEMENT <br />TYPICAL FLOOR SINK <br />w/DOME STRAINER <br />PLAN VIEW <br />" AIR GAP / REMOV. GRATE FOR <br />)OR SINK /�' ACCESS TO CLEAN <br />M DOME STRAINER <br />6/SE. EQUIP..+ <br />G.C. TO GROUT <br />GAP BETWEEN <br />& FLOOR <br />PS -1 MOUNTING <br />SEE DETAIL 'A' FOR <br />B -LINE VIBRACLAMP - BVT <br />ppS���ER�IIrESpppCpLL�AA�MP��ppFTO BE USED ON <br />INSULATI04kLWPWHTIEPASJ AND FITTINGS <br />WHERE REQUIRED - INSTALL <br />ALUMINUM JACKET WHERE <br />EXPOSED TO THE WEATHER, <br />PROVIDE LABELS FOR SERVICE <br />AND FLOW DIRECTION <br />W/MIN 1" HIGH LETTERS <br />'2" ALL THREAD ROD (ATR) <br />TH DOUBLE NUT AND LOCK <br />WASHER AT AT STRUT AND <br />ANGLE CUP <br />SEE DETAIL 'A' FOR <br />ATTACHMENT TO <br />STRUCTURE <br />(E)ROOF FRAMING - 2x6 <br />WOOD JOISTS, 24" OC <br />LATERAL OR LONGITIDUNAL BRACE - SIZE <br />AND SPACING PER SMACNA TABLES <br />5-7,6-7- OR 7-7 OR CPC TABLE 3-1 AND <br />3-2. BRACE ONLY REQUIRED WHEN PIPE IS <br />MORE THAN 12" BELOW STRUCTURE <br />HANGER ROD - SEE CPC TABLE 3-1 OR <br />SMACNA SEISMIC RESTRAINT GUIDELINE <br />TABLES 5-7,6-7 OR 7-7 FOR HANGER <br />ROD SIZES AND CPC TABLE 3-2 FOR <br />SPACING. <br />DOUBLE NUT AT HANGER - <br />INSULATION W/WHITE ASJ <br />FOR PIPE 1-1/2" AND SMALLER OR <br />CALSILICA SUPPORT WHERE <br />REWIRED - INSTALL ALUMINUM <br />JACKET WHERE EXPOSED TO THE <br />WEATHER, PROVIDE LABELS FOR <br />SERVICE AND FLOW DIRECTION <br />W/MIN 1" HIGH LETTERS <br />CLEVIS <br />WITH FLOOR <br />SECTION <br />SEE DETAIL 'A' FOR <br />SEE DETAIL 'A' FOR <br />2x2x1/4"x2" LONG ANGLE <br />CLIP - ATTACH AT <br />MIDPOINT OF PURLOIN WITH <br />1/2"0x2" LONG LAG BOLT, <br />EMBED 1-1/2" MIN. <br />BRACE TO RISE TO RUN <br />(SLOPE) SHALL BE NO MOF <br />THAN 2:1 OR NO LESS <br />THAN 1:2 <br />DOUBLE NUT AND <br />DOUBLE NUT AND <br />PIPE SUPPORT HANGER AND TRAPEEZE - WOOD <br />DETAIL <br />BELOW FINISH <br />OR FLOOR <br />ROAD PAVEMENT WHERE <br />APPLICABLE <br />6" THICK 36" DIAMETER <br />CONCRETE RING WITH <br />1-#4 BAR IN CENTER <br />CONCRETE BOX LABELED SEWER <br />OR' <br />BRASS CLEANOUT BOX <br />IN FINISHED FLOOR <br />3"0 PVC SLEEVE WITH 4"0 <br />-LEANOUT RISER PIPE <br />N�-j.ONG SWEEP 'L' <br />90 DEGREE <br />INVERT - SEE PLAN <br />FOR SIZES <br />SEE PLUMBING FLOOR <br />PLAN FOR SIZE <br />CLEANOUT TO GRADE 6 <br />DETAIL P O <br />BELOW FINISH <br />OR FLOOR <br />CLEVIS <br />DETAIL 'A' <br />THIS DOCUMENT, AND THE IDEAS AND DESIGNS <br />INCORPORATED HEREIN, AS AN INSTRUMENT OF <br />PROFESSIONAL SERVICE, IS THE PROPERTY OF <br />"api" AND IS NOT TO BE USED, IN WHOLE OR IN <br />PART, FOR ANY OTHER PROJECT WITHOUT <br />WRITTEN AUTHORIZATION. <br />PLANNING ■ ■ ■ <br />ARCHITECTURE ■ ■ ■ <br />■ ■ <br />ARCHITECTURE PLUS INC. <br />4335-B NORTH STAR WAY <br />MODESTO, CA 95356 <br />PVC CONNECTION - <br />L2WAY CI IAP M0 <br />B NO.: <br />DO NOT OVERTIGHTEN <br />APPROVED CLEANOUT <br />P.0 <br />AT AC UNIT <br />INVERT - SEE PUN <br />J <br />FOR SIZES <br />SEE PLUMBING FLOOR <br />END OPEN TD AIR COIL LOCATION <br />PLAN FOR SIZE <br />2 -WAY <br />CLEAN❑UT <br />3/4' PVC <br />a <br />Q <br />N <br />w <br />2' <br />O <br />Z <br />COIL COND, PIPING <br />3 <br />W <br />J <br />DETAIL <br />w <br />2 <br />U <br />h <br />PVC CONNECTION <br />Z <br />DD NOT DATRAC <br />UNIT <br />M <br />- T\ -ROAD PAVEMENT WHERE <br />APPLICABLE <br />6" THICK 36" DIAMETER <br />ONCRETE RING WITH <br />I� 1-#4 BAR IN CENTER <br />II CONCRETE BOX LABELED SEWER <br />OR' <br />I BRASS CLEANOUT BOX <br />IN FINISHED FLOOR <br />p 6"0 PVC SLEEVE WITH 4"0 <br />CLEANOUT RISER PIPE <br />END <br />OPEN TO AIR 3/4' PVC -� , AND FLEX SSEMBLYE <br />6' DRIP <br />LINE <br />GAS LINE - SEE PLAN <br />FOR SIZES AND ROUTING <br />GAS AND CONDENSATE, <br />DETAIL P O <br />JOB# 2019-097 <br />GDMD ENGINEERING, INC <br />Mechanical and Safety Engineers <br />212 W Pine St, Ste 4 <br />Lodi, Ca 95242 <br />Ph 209-367-0899 <br />Fax 209-367-0898 <br />E-mail:gdmdengrinc@sbcglobal.net <br />pi COPYRIGHT 2019 <br />ph. 209.577.4661 <br />fx. 209.577.0213 <br />www.apiarc.com <br />FRANK C. BOOTS <br />JOSEPH L. SMITH <br />RODNEY C. ALONZO <br />ARCHITECTS <br />W Z <br />he W o0e <br />Z <br />Oct W O <br />916. <br />2OmS <br />H <br />Q &L O <br />N z <br />ol) <br />in <br />Q Z a <br />Q 0 <br />Z oe <br />W Lu > <br />uI <br />ZI <br />0 <br />L2WAY CI IAP M0 <br />B NO.: <br />18-114 <br />APPROVED CLEANOUT <br />P.0 <br />HECKED : <br />INVERT - SEE PUN <br />FOR SIZES <br />SEE PLUMBING FLOOR <br />PLAN FOR SIZE <br />2 -WAY <br />CLEAN❑UT <br />DETAIL <br />P O <br />END <br />OPEN TO AIR 3/4' PVC -� , AND FLEX SSEMBLYE <br />6' DRIP <br />LINE <br />GAS LINE - SEE PLAN <br />FOR SIZES AND ROUTING <br />GAS AND CONDENSATE, <br />DETAIL P O <br />JOB# 2019-097 <br />GDMD ENGINEERING, INC <br />Mechanical and Safety Engineers <br />212 W Pine St, Ste 4 <br />Lodi, Ca 95242 <br />Ph 209-367-0899 <br />Fax 209-367-0898 <br />E-mail:gdmdengrinc@sbcglobal.net <br />pi COPYRIGHT 2019 <br />ph. 209.577.4661 <br />fx. 209.577.0213 <br />www.apiarc.com <br />FRANK C. BOOTS <br />JOSEPH L. SMITH <br />RODNEY C. ALONZO <br />ARCHITECTS <br />W Z <br />he W o0e <br />Z <br />Oct W O <br />916. <br />2OmS <br />H <br />Q &L O <br />N z <br />ol) <br />in <br />Q Z a <br />Q 0 <br />Z oe <br />W Lu > <br />uI <br />ZI <br />0 <br />SHEET <br />To <br />AUGUST 2019 <br />B NO.: <br />18-114 <br />rTE: <br />AWN <br />P.0 <br />HECKED : <br />G.D <br />SHEET <br />To <br />