Laserfiche WebLink
04/01/2004 13:25 4640138 ENVIRONMENTAL HEALTH PAGE 01 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> COUNTY tIM,N.,w",mr, <br /> �• i, ,p nonnn <br /> K.iteran,R,R,W•KI`;"h'is :',;_�'• , v� <br /> `.' 304 East Weber Avenue,Third Floor Carl Ai+rn, R.C.R . <br /> { sen,cloy Mlko Flugainn,A.L•.FIS.,R.D.I. <br /> �''• sloven,R.&fl.j 23 SfbdA$n`. &lifornia 95202-2708 U",alae W.wllmr, R.,V.M.8, <br /> i .,, ;�� Program Manggr�k}l <br /> Telephone! 209)468-3420 Ma, arca 6agarin,R.r.ta.5. <br /> /4a' 4+e,ie A.Corpus,R.E.H.-P. Fax: (209)464-0135 Ra6crl MaClollan,RH.S. <br /> Prox�'em Mnnagxr ,Mark natalla+,A.AR& <br /> February 24, 2004 <br /> Gary Bollami <br /> EI Dorado Fools <br /> 317W. Linwood Avc, <br /> Turlock CA 95380 <br /> RE: Proposed Therapy Fool at 2303.W.March Lane(Quail Lakes Athletic Club) <br /> The plans submitted on January 27',2004 to this Department for the proposed therapy <br /> pool at Quail Lakes Athletic Club are denied approval at this time. The plans must be <br /> resubmitted to include the following list of itepta that are incomplete on the plans: <br /> 1. Indicate the number of pumps to be used,the model numbers of the pumps,pump <br /> curves,and the horsepower of all pumps. <br /> 2. Show the make and model of the filter you ale proposing. <br /> 3. Show greater detail oil the plumbing to be used. Indicate sizes of plumbing on the <br /> suction and return side of pumps. <br /> 4. Provide this Department with cut sheets for all equipment to be used(pumps, <br /> filters,main drain covers,equalizer line covers,skimmers,lights,heater„ <br /> chlorinator,flow meter, coping around perimeter of pool, ctc). <br /> 5. A second skimmer will need to be installed. Show location: <br /> ✓6. Sidewall mounted main drains are not approved. Swim jet suction roust be floor <br /> mounted and be an approved type of cover. <br /> ✓ 7. Separate the main drain filter suction line from the skimmer line. These must be <br /> separate lines all the way into the equipment TOOm. <br /> 8. A means of entry and exit into the pool must be provided in the deep end of the <br /> pool because the depth,is greater then 4 ya feet. Indicate location. <br /> 9, provide an example of the depth marker tiles to be used on tho plans. Indicate <br /> location of tiles around the pool, <br /> V 10.The coping around the pool cannot be over 2 %inches thick and shall have an <br /> overhangbetween 1 to 2 inches. <br /> 11. Indicate dimensions of the pool bench. Maximum water depth over the bench is <br /> 24 inches. <br /> 12. Indicate pool gallonage and turnover needed. A special purpose pool shall have a <br /> turnover of two hours. , <br /> V 13. Foto feet oru—nobstrueted deck is needed around entire pool. Show this on plans. <br />