My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
15999
>
2800 - Aboveground Petroleum Storage Program
>
PR0528989
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/5/2022 9:31:57 AM
Creation date
2/5/2021 4:33:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0528989
PE
2832
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A NJ O A Q U l N Environmental Health Department <br /> COUNTY— <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Lawrence Livermore National Lab-Site 300 15999 W CORRAL HOLLOW RD, TRACY December 07, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 604 CFR 112.7(a)(3)(i)Plan failed to include oil type and storage capacity for each container. <br /> OBSERVATION: The Spill Prevention, Control, and Countermeasure(SPCC)Plan failed to address the type of oil <br /> and storage capacity for each fixed container. Generator 801ATFBD01 with storage capacity of 358-gallons, located <br /> outside building 801A is not included in the list of Oil-Filled Stationary Generators in Appendix C,Table C1 —S300 <br /> SPCC Plan Inventory, Oil-Filled Stationary Generators on pages C-4—C-6 in the SPCC Plan last updated April <br /> 2021. During the inspection,the facility showed EHD that generator 801ATFBD01 was included on a master list <br /> Excel sheet that the facility provided to the professional engineer for review. Though generator 801AFTBD01 was <br /> included on the master list,the facility stated that due to a typographical error for that generator on the'Equipment <br /> Type Identifiers'column on the master list Excel sheet, generator 801AFTBD01 was left off of the Oil-Filled <br /> Stationary Generators list that was carried over to the actual SPCC Plan (Appendix C,Table C1, pages C-4—C-6). <br /> Generator 801AFTBD01 had the identifier'SatGen 16'instead of'StatGen16'in the master list. Per facility,the <br /> identifiers on the master list sort out the SPCC Plan inventory into separate sheets based on SPCC oil equipment <br /> type (Bulk, Portable, Electrical Equipment, Operating Equipment, Portable Generators and Stationary Generator). <br /> Each sheet with the different SPCC oil equipment types are included in the SPCC Plan as their own table to <br /> organize the various equipment types.As a result of the typographical error, generator 801AFTBD01 was not <br /> included in Appendix C,Table C1.Appendix C is referenced throughout the plan as where to get information on the <br /> SPCC container inventory, however the master list is not referenced in the SPCC Plan as a source of information. <br /> Appendix C, page C-11 for the Total Oil Storage Capacity for the facility does not include generator 801ATFBD01 in <br /> the count for the Oil-Filled Stationary Generators or the Grand Total Oil Storage Capacity. Generator 801ATFBD01 <br /> was included on the site map but it does not show the storage capacity. <br /> REGULATION GUIDANCE: The SPCC plan shall include: 112.7(a)(3)(i)The type of oil in each fixed container and <br /> its storage capacity. For mobile or portable containers, either provide the type of oil and storage capacity for each <br /> container or provide an estimate of the potential number of mobile or portable containers,the types of oil, and <br /> anticipated storage capacities. <br /> CORRECTIVE ACTION: The SPCC Plan shall properly address the type and storage capacity of all fixed and <br /> portable and/or mobile containers, as required. Submit proof of correction to the EHD. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. A complete report was <br /> finished on 1/4/2022 and replaces the initial checklist. Item #604 was added to the inspection report. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> Multi-day inspection, began on 12/6/2021 completed on 12/7/2021. <br /> Inspection checklist emailed to: <br /> Ashley Thomas (thomas257@llnl.gov), Jon Blazo (blazo1@llnl.gov), Stephanie Bibby (bibby2@llnl.gov), Paul <br /> Roy (roy25@llnl.gov) <br /> FA0003934 PR0528989 SCO01 12/07/2021 <br /> EHD 28-01 Rev.12/06/2021 Page 5 of 6 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.