Laserfiche WebLink
SAN JOAQUIN Environmental Health Department <br /> C0JNTY- <br /> rSc, n Greotness grows here. <br /> Food Program Service Request Inspection Report <br /> Facility Name and Address: CLUKIN ROOSTER, 7628 PACIFIC AVE , STOCKTON 95207 <br /> #38 Approved/Sufficient Ventilation and Lighting <br /> OBSERVATIONS:Light bulbs at waitress station lack covers. Provide covers or lights shall be shatter proof. <br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases,heat,grease, vapors and smoke and be approved by <br /> the local building department. Canopy-type hoods shall extend 6"beyond all cooking equipment.All areas shall have sufficient ventilation <br /> to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window,an air shaft,or a <br /> light-switch activated exhaust fan,consistent with local building codes. (114149, 114149.1)Adequate lighting shall be provided in all areas <br /> to facilitate cleaning and inspection.Light fixtures in areas where open food is stored,served,prepared,and where utensils are washed <br /> shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1) <br /> #39 Thermometers Provided/Accurate/Easily Visible <br /> OBSERVATIONS:Provide probe thermometers. Hot food shall be kept at 135 F or higher and cold food 41 F or lower. <br /> CALCODE DESCRIPTION:An accurate easily readable metal probe thermometer suitable for measuring temperature of food shall be <br /> available to the food handler. A thermometer+/-2#F shall be provided for each hot and cold holding unit of potentially hazardous foods <br /> and high temperature warewashing machines. (114157, 114159) <br /> #45 Floors,Walls, Ceilings; Clean and Maintained <br /> OBSERVATIONS:Old cabinets at waitress areas are going to be removed in the next few days. New floors and walls shall <br /> be up to code. Floors shall be commercial sheet linoleum and base shall be coved with 3/8 inch radius and extend 4-6 <br /> inches to wall. RUBBER COVING IS NOT ALLOWED.Walls shall be smooth, cleanable, and non absorbent. <br /> Kitchen has several absorbent and stained ceiling panels. Replace with vinyl coated panels by 1-2 weeks. <br /> CALCODE DESCRIPTION: The walls/ceilings shall have durable,smooth,nonabsorbent,light-colored,and washable surfaces. All floor <br /> surfaces, other than the customer service areas, shall be approved, smooth, durable and made of nonabsorbent material that is easily <br /> cleanable.Approved base coving shall be provided in all areas,except customer service areas and where food is stored in original <br /> unopened containers. Food facilities shall be fully enclosed. All food facilities shall be kept clean and in good repair. (114143(d), <br /> 114266, 114268, 114268.1, 114271, 114272) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Name on Food Safety Certificate: Expiration Date: <br /> Warewash Chlorine(Cl): 50 ppm Heat: °F Water/Hot Water Ware Sink Temp: 1451 F <br /> Quaternary Ammonia(QA): ppm Hand Sink Temp: 1251 F <br /> FOOD ITEM--LOCATION--TEMP°F--COMMENTS <br /> large prep cooler at cooks line--39.00°F walk in--38.00°F <br /> NOTES <br /> Ok to issue permit once fee is paid. Return to the office to turn in pink/green forms and payment of$425. Program element <br /> 1626 <br /> Equipment: Dishwasher, 3 comp sink, hand sink, mop basin (on the exterior) <br /> FA0002654 SR0083701 SC061 05/18/2021 <br /> EHD 16-23 Rev.09/16/2020 Page 2 of 3 Food Program Service Request Inspection Report <br />