My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
141
>
2300 - Underground Storage Tank Program
>
PR0543574
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2022 4:20:35 PM
Creation date
2/10/2021 4:19:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0543574
PE
2351
FACILITY_ID
FA0024750
FACILITY_NAME
Harney Lane 76
STREET_NUMBER
141
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
141 E HARNEY LN
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of underground storage tank violations that have not <br />been addressed for Harney Lane 76 as of December 06, 2021. <br />Open violations from August 18, 2021 inspection <br />Violation #208 - Failure to comply with the designated operator inspection requirements. <br />OBSERVATION: The last DO monthly inspection report found on site was dated 5/28/2021. There is no indication <br />that a monthly inspection has been performed for the month of June and July. More than 30 days has passed since <br />the last inspection. <br />REGULATION GUIDANCE: The designated operator visual inspections shall be conducted within 30 days or less of <br />the previous inspection. <br />CORRECTIVE ACTION: Ensure that all designated operator inspections are performed within the required time <br />frames. <br />OBSERVATION: The designated operator failed to document all the alarms from the attached alarm history on the <br />following reports: <br />- 4/2/2021: Q1 Alarm on 3/12/2021 <br />- 4/30/2021: S2 -S7 Alarm on 4/22/2021 <br />- 5/28/2021: 1-1-1-28, Q1 -Q3, S9 -S13 Alarms on 5/4/2021 <br />REGULATION GUIDANCE: During the inspection, the designated operator shall review the alarm history since the <br />previous inspection, check that each alarm was documented and responded to appropriately, and attach a copy of <br />the alarm history with documentation taken in response to any alarms to the inspection report. <br />CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of <br />the required information on the reports. <br />OBSERVATION: Designated operator reports were not signed by the Owner or Operator for the March 2021 -May <br />2021 reports. The reports were signed by the following individuals: Silvia Mendoza, Ashley D, Mindy Duran, Gopi <br />Kheira. These individuals are not the owner/operator and there are no training records on file for them. The <br />February 15, 2021 DO report did not include the name of the person who signed the report. <br />REGULATORY GUIDANCE: Within 48 hours of the completion of the designated UST operator visual inspection, <br />the designated operator shall sign and provide the owner or operator with a copy of the inspection report. Within 72 <br />hours of being provided a signed copy of the report, the owner or operator shall provide a description of each <br />corrective action taken or to be taken and shall sign and date the report, acknowledging the identified compliance <br />issues. <br />CORRECTIVE ACTION: Ensure all designated operator inspection reports are completed and signed within the <br />required time frame in the future. <br />OBSERVATION: The designated operator incorrectly documented the test dates for the Secondary Containment on <br />the designated operator inspection report as 7/7/2020 on the 2/15/2021 report. This is a VPH site and we have no <br />records of a secondary containment test being conducted. The designated operator incorrectly documented the test <br />dates for the Overfill Prevention inspection on the February 2021 - May 2021 designated operator inspection report <br />as 7/7/2021. Per the EHD records the Overfill Prevention Inspection was conducted on 6/4/2020. <br />Page 5 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.