My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOSPITAL
>
500
>
2300 - Underground Storage Tank Program
>
PR0231614
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2022 4:16:58 PM
Creation date
2/16/2021 1:52:52 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231614
PE
2361
FACILITY_ID
FA0000086
FACILITY_NAME
San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
109
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N J Q Q Q U IN Environmental Health Department <br /> C O U N T Y Time In: <br /> Time Out: <br /> Greorness grows here. <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: San Joaquin General Hospital Date: 10/11/2021 <br /> Address: 500 W Hospital RD , FRENCH CAMP 95231 <br /> Requestor: ANN MARIE OR JOE, BAGLEY ENTERPRISES INC Telephone: (209)367-4800 <br /> Program Element: 2308-UST RETROFIT Request#: SR0084286 <br /> Inspection Type: 298-UST RETROFIT REPAIR INSPECTION <br /> Onsite Service Technician: Andrew Bagley ICC Service Tech/Installer Exp. Date: 11/12/2022 <br /> Manufacturer training: OPW, 01/22/22 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On site for the following inspection on the diesel tank underground storage system.: <br /> Overfill prevention equipment verification and tank charts: <br /> -Verified measurement of OPW drop tube set at 92%tank volume. <br /> -Verified flapper functionality <br /> This facility is not approve to receive fuel in the diesel tank until ball floats are verified. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead of having them <br /> sign. <br /> Note: Incomplete inspection:The technician was unable to verify ball floats. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: E mailed to: Jesse Escotto, Environm <br /> EH Specialist: PAUL NSO Phone: (209)616-3049 <br /> SR0084286 SC298 10/11/2021 <br /> EHD 23-01 Rev.09/16/2020 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.