Laserfiche WebLink
SAN J O A R N Environmental Health Department <br /> i , �V <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> H&S Energy Products,#3035 192 Lathrop Rd, Lathrop January 13, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. <br /> OBSERVATION: The designated operator failed to check and note all required items on the visual inspection <br /> reports.The incorrect and missing information included the following from the inspection reports: <br /> -Several questions were left blank in section VIII. <br /> -The designated operator signature was left blank. <br /> -No UDCs were listed. <br /> -Line and tank tightness testing questions were left blank. <br /> -Incorrect overfill test dates were listed. <br /> -The reports state that sump sensors were properly located, but no sumps were listed as having been inspected. <br /> REGULATION GUIDANCE: During the visual inspection,the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports. <br /> This is a repeat violation, Class II. <br /> 209 CCR 2715(c)(3), 2715(c)(4) Failure to maintain a copy of the"Facility Employee Training Certificate"on-site. <br /> OBSERVATION: The Facility Employee Training Certificates list incorrect initial training dates and list"hire dates" <br /> under the"date of assuming responsibility"column. The"initial training dates"are the same as the"date of training" <br /> and do not match with previous year's records for the same employee. <br /> REGULATION GUIDANCE:All site employees must be trained prior to taking responsibility as a facility employee if <br /> after October 1, 2018, or within 30 days of hire if prior to October 1, 2018. The Facility Employee Training <br /> Certificate shall contain accurate information for all employees trained. <br /> CORRECTIVE ACTION: Update the Facility Employee Training Certificate to contain the accurate information and <br /> submit a copy of the updated form to the EHD. <br /> This is a repeat violation, Class II. <br /> 301 HSC 25292.1(a)Failure to operate UST system to prevent unauthorized releases including leaks, spills and overfills. <br /> OBSERVATION: The fuel filter under the north side of dispenser 15/16 is not located to allow drips and leaks to <br /> drain back into the UDC. A deflector plate is present on the south side, but not the north. <br /> REGULATION GUIDANCE: The underground storage tank system shall be operated to prevent unauthorized <br /> releases. <br /> CORRECTIVE ACTION: Immediately provide approved secondary containment for the filters under permit and <br /> inspection by the EHD. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> FA0007059 PR0505867 SCO01 01/13/2021 <br /> EHD 23-01 Rev.9/20/2019 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />