Laserfiche WebLink
2' aU 'N\ 2 SAN 10AQ U I N Environmental Health Department <br /> pP .. .. ... .. C\ <br /> Jas It Kan REHS Director <br /> COUNTY J g > > <br /> o° P,_FoGreatness grows here . Muniappa Naidu , REHS , Assistant Director <br /> a� . <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> February 3 , 2021 <br /> SCOTT WILLETT <br /> DIMAGGIO MAINTENANCE , INC . <br /> 1040 JOSHUA WAY <br /> VISTA , CA 92081 <br /> SR0083186 <br /> Re : GRANT LINE SHELL* <br /> 2375 W GRANT LINE RD <br /> TRACY , CA 95376 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of <br /> the application for a permit for the following repairs on the underground storage tank ( UST) system <br /> at the above noted address : <br /> - Install new overfill prevention equipment in the 87 , 89 , 91 and diesel tanks <br /> - Remove all ball floats in the 87 , 891 91 and diesel tanks <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District <br /> for any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust ( slgov . org to arrange the following appointments ( a 48 - <br /> hour notice is required for inspection appointments ) . <br /> a . Overfill prevention verification : Measurement of drop tubes to verify 95 % tank volume <br /> shut off. Verification of flapper functionality . Ensure that all pertinent tank charts and <br /> calculations are available for review at the time of inspection . <br /> b . Verification that ball float ( s ) are removed <br /> Please be aware that the facility cannot receive fuel in the 87 , 89 , 91 , and diesel <br /> tanks prior to the EHD inspection and approval . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be <br /> issued to the installation company) , or a Tank Tester' s license issued to the individual <br /> by the State Water Board , and <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service <br /> Technician certificate issued by the International Code Council ( ICC ) , and <br /> c . Possesses a valid , current certificate of training from the manufacturer(s) of the <br /> component (s) being tested , repaired , or serviced . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjgov . org/ehd <br />