My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2375
>
2300 - Underground Storage Tank Program
>
PR0232469
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/22/2022 8:48:19 AM
Creation date
2/17/2021 8:08:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0232469
PE
2361
FACILITY_ID
FA0003772
FACILITY_NAME
GRANT LINE SHELL*
STREET_NUMBER
2375
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21402017
CURRENT_STATUS
01
SITE_LOCATION
2375 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
213
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANOAQU I N Environmental Health Department <br />COU NI T Y I Y Time In: <br />+_,fr Time Out: <br />Greotr+ess �row3 here. <br />Underground Storage Tank Program Service Request Inspection Report <br />Name of Facility: GRANT LINE SHELL' <br />Date: 10/06/2021 <br />Address: 2375 W GRANT LINE RD, TRACY 95376 <br />Requestor: SCOTT WILLETT, DIMAGGIO MAINTENANCE, INC. <br />Telephone: (760) 722-9002 <br />Program Element: 2308 - UST RETROFIT <br />Request #: SR0083186 <br />Inspection Type: 298 - UST RETROFIT REPAIR INSPECTION <br />Onsite Service Technician: Chad White <br />ICC Service Tech/Installer Exp. Date: 02/13/2022 <br />Manufacturer training: FF, 05/30/22 <br />OVERALL INSPECTION NOTES AND COMMENTS <br />NOTES <br />On site to: <br />- Witness overfill prevention testing of installed Franklin Fueling Defender Series overfill prevention valve. <br />- Verified tank charts and calculations with technician (Xerxes 12,000 -gallon, installed 6/6/1991) <br />- All 4 drop tubes are currently set above 95% <br />- Could not verify ball floats have been removed. There is a 90 degree bend in the vent pipes to prevent direct view to the tank <br />from the vent pipe. Per the technician, to verify that ball floats have been removed, the cap of the vent pipe coming directly <br />above the tank would need to be removed. The technician attempted to remove the cap to observe the vent pipe but it was <br />rusted and could not be removed. See photo of tank sump with the 90 degree angle. <br />This facility is not approved to receive fuel in the 87, 87 auxiliary, 91 and diesel tanks. <br />Please schedule an appointment through UST@sjgov.org with 48-hour notice to <br />- verify overfill prevention valves (drop tubes/flappers) are set at 95% shut off <br />- verify ball floats have been removed <br />Please refer to SR0083186 permit approval letter dated 2/3/2021 for more information. <br />Inspection report emailed to: <br />scott@dimaggiomaintenance.com <br />grantlineshell@carenterprisesinc.net <br />sireifej@carenterprises.net <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: <br />EH Specialist: CAROL PRESTO <br />Name and Title: Emailed to Scott Willett, <br />Phone: (209) 616-3061 <br />FA0003772 SR0083186 SC298 10/06/2021 <br />EHD 23-01 Rev. 09/16/2020 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.