DIVISION 09 - FINISHES DIVISION 31 - EARTHWORK <br /> GYPSUM BOARD <br /> QUALITY CONTROL SOILS REPORT: CERAMIC TILE WALL COVERING <br /> MATERIAL SHALL MEET OR EXCEED THE FOLLOWING STANDARDS INSTALLATION OF ACCESSORIES: INSTALL CORNER TRIM AT VERTICAL AND DIVISION 10 - SPECIALTIES THIS SECTION IS NOT USED <br /> HORIZONTAL EXTERNAL CORNERS AND ANGLES, AND EDGE TRIM AT ALL WORK SHALL BE IN CONFORMANCE WITH THE SOILS, COMPACTION AND <br /> JUNCTIONS OF WALLBOARD AND OTHER MATERIALS AND AT EXPOSED EDGES. DIVISION 11 - EQUIPMENT THIS SECTION IS NOT USED GEOLOGICAL REPORT. 1. TILE: INTERCERAMIC 1. FRP WALL PANELS <br /> CEMENT PLASTER -3 COAT SYSTEM : T-1 16x24 CERAMIC, HABITAT DURABODY, SMOKE FRP-1 : WALL PANELS <br /> • APPLICATION SHALL BE IN COMPLIANCE WITH APPLICABLE SECTIONS OF TAPING AND FINISHINGFINISH LEVELS: UNLESS OTHERWISE SCHEDULED, DIVISION 12 - FURNISHINGS THIS SECTION IS NOT USED THE CONTRACTOR SHALL HAVE THE SOILS ENGINEER REVIEW AND - PATTERN: 1/2 RUNNING BOND IN RESTROOM / - MANUFACTURER: MARLITE <br /> ANSI A42.2 "PORTLAND CEMENT AND PORTLAND CEMENT-LIME REQUIRED FINISH LEVELS FOR VARIOUS AREAS SHALL BE AS FOLLOWS: STACKED BOND IN HALLWAY REF: INTERIOR -COLOR: P-100 (WHITE) <br /> PLASTERING, EXTERIOR (STUCCO)AND INTERIOR"'AND ANSI A42.3 APPROVE IN WRITING TO THE BUILDING OFFICIAL AND ARCHITECT THAT ELEVATIONS - FINISH: SMOOTH GLOOC, PEBBLE FINISH <br /> DIVISION 13 - SPECIAL CONSTRUCTION THIS SECTION IS NOT USED THE FOUNDATION AND SITE DESIGN ARE IN CONFORMANCE WITH THE <br /> "LATHING AND FURRING FOR PORTLAND CEMENT AND PORTLAND LEVEL 1: EMBED TAPE AT JOINTS IN CEILING PLENUM AREAS, CONCEALED SOILS REPORT PRIOR TO COMMENCEMENT OF WORK. - GROUT LINE: 3/16" - FIRE CLASSIFICATION: TYPE C <br /> CEMENT-LIME PLASTERING, EXTERIOR (STUCCO)AND INTERIOR. AREAS, UNLESS A HIGHER LEVEL OF FINISH IS REQUIRED FOR FIRE- DIVISION 14 - CONVEYING SYSTEMS THIS SECTION IS NOT USED -THINSET: VERSABOND GRAY THINSET, 50LB BAG - FLAME SPREAD: <200 <br /> • IN ADDITION, MATERIALS SHALL MEET OR EXCEED THE FOLLOWING: RESISTANCE-RATED ASSEMBLIES AND SOUND-RATED ASSEMBLIES. - GROUT: POLYBLEND SANDED GROUT, #183 -SMOKE DENSITY: <450 <br /> • THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR COMPLIANCE <br /> PORTLAND CEMENT: ASTM C 150, TYPE I, NATURAL COLOR. SPECIAL LEVEL 2: EMBED TAPE AND APPLY SEPARATE FRIST COAT OF JOINT DIVISION 15-20 - UNASSIGNED THIS SECTION IS NOT USED WITH ALL RECOMMENDATIONS OF THE SOILS REPORT. CHATEAU, 25 LB BAG - LIGHT RV: 83.0%T-2 : 7x36 CERAMIC, SUNWOOD PRO DURABODY, - NOTE: APPLY WITH MARLITE C-375 <br /> FINISHING HYDRATED LIME: ASTM C 206, TYPE S. AGGREGATES: ASTM C COMPOUND ON TAPE, FASTENERS, AND TRIM FLANGES WHERE GYPSUM <br /> 144, ALL SAND TO PASS NO. 8 SIEVE. CEMENT PLASTER FINISH COAT: A PANELS ARE THE SUBSTRATE FOR TILE. LEGEND BEIGE CONSTRUCTION ADHESIVE MOLDING AT ALL INSIDE <br /> PACKAGED BLEND OF PORTLAND CEMENT (ASTM C 150), HYDRATED LIME PRIOR TO THE CONTRACTOR REQUESTING A FOUNDATION INSPECTION BY - PATTERN: 1/3 OFFSET RUNNING BOND CORNERS, AND "J" MOLDING WHERE WALL PANEL <br /> LEVEL 3: EMBED TAPE AND APPLY SEPARATE FIRST AND FILL COATS OF JOINT DIVISION 21 - FIRE SUPPRESSION THE BUILDING DEPARTMENT, THE SOILS ENGINEER SHALL ADVISE THE 5865 Owens Drive <br /> (ASTM C 206), AND PROPERLY GRADED QUALITY 20 MESH AGGREGATE, COMPOUND TO TAPE, FASTENERS, AND TRIM FLANGES, WHERE GYPSUM BUILDING OFFICIAL AND ARCHITECT IN WRITING THAT: - GROUT LINE: 3/16" TERMINATED. <br /> WITH INTEGRAL COLOR AND PAINT FINISH. MIXES: JOB-MIXED CEMENT PANELS ARE THE SUBSTRATE FOR HEAVY TEXTURED FINISHES AND WHERE -THINSET: VERSABOND GRAY THINSET, 50 LB BAG Pleasanton, CA 94588 <br /> PLASTER MIX, BONDCRETE OR MORTASEAL MASON'S LIME WITH LIGHTING CONDITIONS ARE NOT CRITICAL. 21.01 GENERAL REQUIREMENTS SITE GRADING, SUBGRADE PREPARATION, CUTTING SLOPES, EXCAVATION, - GROUT: CBP POLYBLEND SANDED GROUT, #183 2. WALK-IN COOLER UNIT WALLS: 925-251-7200 <br /> PORTLAND CEMENT AND SAND IN ACCORDANCE WITH ANSI A42.2, TYPE L. LEVEL 4: EMBED TAPE AND APPLY SEPARATE FIRST, FILL, AND FINISH COATS FIRE SPRINKLER SYSTEM SHALL BE "DESIGN-BUILD"AND ARE NOT A PART OF PLACEMENT OF ENGINEERED FILL MATERIAL AND COMPACTION IS IN CHATEAU, 25 LB BAG INTERIOR: SMOOTH PEBBLE TEXTURE GALVINIZED SKIN <br /> PROPORTIONS: OF JOINT COMPOUND TO TAPE, FASTENERS, AND TRIM FLANGES. LEVEL 4 IS THE ARCHITECTURAL DOCUMENTS. LAYOUT OF SPRINKLER HEADS SHALL BE ACCORDANCE WITH THE SOILS REPORT. T-5 - 3x6 COLOR BODY CERAMIC, IC BRITES, ULTRA EXTERIOR: T-5 TO 9'-4"THEN PAINTED GYP. BOARD <br /> SCRATCH COAT: 1 BAG PORTLAND CEMENT, 3/4 TO 1 BAG THE STANDARD FOR ALL EXPOSED AREAS, EXCEPT THOSE INDICATED BELOW SUBMITTED TO THE ARCHITECT FOR REVISION. FIRE SPRINKLER PLANS AND WHITE ABOVE. (SEE INTERIOR ELEVATIONS FOR LOCATION OF <br /> LIME TO 6 CU. FT. SAND. FOR LEVEL 5. CALCULATIONS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT FOR THE UTILITY TRENCHES HAVE BEEN PROPERLY BACKFILLED AND - PATTERN: RUNNING BOND WALL TILES T-5) <br /> BROWN COAT: 1 BAG PORTLAND CEMENT, 1 BAG LIME, 6 TO LEVEL 5: EMBED TAPE AND APPLY SEPARATE FIRST, FILL, AND FINISH COATS JURRISDICTIONS HAVING AUTHORITY PRIOR TO INSTALLATION.AUTOMATIC COMPACTED. - GROUT LINE: 1/8" <br /> 7 CU. FT. SAND. OF JOINT COMPOUND TO TAPE, FASTENERS, AND TRIM FLANGES, AND APPLY FIRE SPRINKLER SYSTEM SHALL BE DESIGNED AND INSTALLED IN -THINSET: VERSABOND WHITE THINSET, 50 LB <br /> FINISH COAT: 1 BAG PORTLAND CEMENT, 2 BAGS LIME, 7 SKIM COAT OF JOINT COMPOUND OVER ENTIRE SURFACE. USE THIS FINISH ACCORDANCE WITH NFPA 13D AS A MINUMUM THE FOUNDATION EXCAVATIONS, FORMING, FOOTING AND PIER DEPTHS, BAG <br /> TO 10 CU. FT. SAND. SEE DRAWINGS FOR LEVEL IN AREAS AS FOLLOWS: AND REINFORCEMENT COMPLY WITH THE SOILS REPORT ANDAPPROVED - GROUT: POLYBLEND DRY GROUT UNSANDED, <br /> LOCATION OF CEMENT PLASTER FINISH COAT. RECEIVING GLOSS OR SEMI-GLOSS CONDITIONS. PLANS. WHITE, 25 LB BAG CORNER GUARDS• MAXIMUM SLUMP: 2-1/2 IN. USING SLUMP TEST ASTM C 143, MODIFIED AREAS SUBJECT TO SEVERE LIGHTING CONDITIONS. - PROVIDE BULLNOSE TILE EDGE AS SPECIFIED ON 1. CORNER GUARD: <br /> ELEVATIONS. <br /> SLUMP CONE 2 IN. X 4 IN. X 6 IN. WALL METAL LATH: AT VERTICAL AREAS SCHEDULED TO RECEIVE SPECIAL DRY-ERASE MARKER PAINT. DIVISION 22 - PLUMBING GENERAL REQUIREMENTS CG-1 <br /> SURFACE: NO. 17 GAUGE GALVANIZED STUCCO NETTING MEETING AREAS SCHEDULED TO RECEIVE FILM-APPLIED OR PAINTED WALL THE SITE PLAN IS NOT A SURVEY. IT IS BASED ON SITE INFORMATION <br /> FEDERAL SPECIFICATION QQ-L-101WITH TWO HORIZONTAL NO. 19 GAUGE 2. CLEANING PRODUCTS FILA-DETERDEK 5 LITER (INITIAL -GENERAL: USED WITH FRP-1 <br /> GRAPHICS. SEE PLUMBING DRAWINGS FOR SPECIFIC INFORMATION RELATED TO PROVIDED BY THE OWNER AND IS FOR BUILDING AND SITE WORK LAYOUT <br /> GALVANIZED WIRES AT 6 INCHES O.C. OVER TWO LAYERS OF GRADE 'D' CLEANING BY GC) - MANUFACTURER: MARLITE <br /> ALL CURVED WORK PLUMBING REQUIREMENTS ONLY. THE CONTRACTOR SHALL VERIFY ON SITE ALL GRADES, SOIL - MODEL: 'FRP' CORNER GUARDS AND MOLDING <br /> PAPER (60 MIN.). SEE DIVISION 07. ALL EXPOSED GYPSUM BOARD AT PUBLIC DINING AREAS CONDITIONS, GROUND WATER, EXISTING IMPROVEMENTS, PROPERTY -SIZE: 1-1/2"x 1-1/2"x 120" <br /> • LATH AT HORIZONTAL SOFFIT: GALVANIZED MESH, 3.4 LBS/SQ. YD. OVER LINES, EASEMENTS, SETBACKS, UTILITIES AND SUBSTRUCTURES. WHERE 3. FLOOR LEVELING COMPOUND: HYDROMENT/ BOSTIK <br /> 1 LAYER OF GRADED' PAPER (60 MIN.). STAPLES: 14 GAUGE WIRE SL150, SELF LEVELING BOSTIK UNIVERSAL PRIMER (USED -COLOR P-100 (WHITE) CONSULTANT <br /> DIVISION 23 - HEATING, VENTILATION, & AIR CONDITIONING DISCREPANCIES WITH THE DRAWINGS OCCUR, CONTACT ARCHITECT. WITH SL 150) - PROVIDE FULL HEIGHT CORNER GUARDS AND 'T' <br /> STAPLES, DIVERGENT POINTS, 3/4 INCH CROWN, LIN. LEGS. NAILS (IF FIELD SAMPLE: A SAMPLE PANEL SHALL BE PREPARED APPROXIMATELY 2 FEET GRADE SURFACE OF FILL UNDER CONCRETE SLABS SHALL BE SMOOTH MOLDING <br /> SOFFIT SUPPORTED BY WOOD FRAMING): 1 3/4 INCH 11 GAUGE, 3/8" BY 2 FEET. THIS SAMPLE PANEL WILL BE A SEPARATE PART OF THE PROJECT. SEE MECHANICAL DRAWINGS FOR SPECIFIC INFORMATION RELATED TO AND EVEN, FREE OF VOIDS,COMPACTED AS SPECIFIED AND TO REQUIRED -AT ALL OUTSIDE CORNERS AND JOINTS. TRIM 'T' <br /> HEAD, 3/4"WASHER. STUCCO ACCESSORIES SHALL MEET OR EXCEED ALL PRE-PACKAGED THIN SET MORTAR IS FORMULATED <br /> INSTALLATION SHALL NOT PROCEED UNTIL THE ARCHITECT AND OWNER HEATING, VENTILATION &AIR CONDITIONING REQUIREMENTS. ELEVATION. MOLDING AND CORNER GUARDS FLUSH AT TOP <br /> THE CIRTERIA OF ASTM C 1063 ACCEPT THE SAMPLE PANEL. THE SAMPLE SHALL SHOW COLOR, TEXTURE, TO MEET INDUSTRY REQUIREMENTS OF ANSI AND TCNA <br /> TO PROPERLY PERFORM IN SPECIFIC TYPES OF OF WALL BASE. <br /> AND WORKMANSHIP OF FINISHED WORK. WAV CEMENT PLASTER, GENERAL: AT RAISED FOUNDATIONS, PAD GRADE UNDER BUILDING SHALL HAVE INSTALLATION. BLENDING OF STANDARD THIN SET -APPLIED WITH TITEBOND ADVANCED POLYMER <br /> DIVISION 24 - UNASSIGNED POSITIVE SLOPE TO A PERFORATED DRAIN SET IN GRAVEL TRENCH. FRP ADHESIVE <br /> • INSTALLATION SHALL COMPLY WITH CBC 2510.3 OR CRC 703.7. MORTAR WITH RAPID SETTING MORTAR WILL AFFECT <br /> CG-2 <br /> • CONTROL JOINTS SHALL BE INSTALLED PER ASTM C 1063: EXTEND PIPE TO ALL PORTIONS OF UNDER FLOOR AREA. THE DRAIN SHALL DISCHARGE INTO THE STREET OR APPROVED DRAINAGE FACILITY. SHRINKAGE AND ULTIMATE STRENGTH OF THE MORTAR. <br /> NO LENGTH SHOULD BE GREATER THAN 18 FT. IN EITHER THIS SECTION IS NOT USED CUSTOM BUILDING PRODUCTS WILL NOT WARRANT JOBS -GENERAL: PROVIDED BY GC <br /> DIRECTION TILE AND STONE SETTING MATERIAL AND ACCESSORIES: UNLESS OTHERWISE DETAILED OR NOTED, A PERFORATED DRAIN SET INA WHERE THIN SET MORTARS HAVE BEEN MODIFIED WITH - MANUFACTURER: SCHLUTER <br /> NO PANEL SHOULD EXCEED 144 SQ. FT. FOR VERTICAL UNAUTHORIZED MATERIALS; WHICH INCLUDES BLEND - MODEL: RONDEC ����� <br /> GRAVEL TRENCH SHALL BE INSTALLED AROUND THE ENTIRE PERIMETER OF <br /> APPLICATIONS 1.3 REFERENCES DIVISION 25 - INTEGRATED AUTOMATION WITH OTHER CUSTOM BUILDING PRODUCTS THIN SET - FINISH: SATIN ANODIZED ALUMINUM, RO 125 AE <br /> NO PANEL SHOULD EXCEED 100 SQ. FT. FOR HORIZONTAL, A. ANSI A108 SERIES/A118 SERIES-AMERICAN NATIONAL STANDARDS FOR THE FOUNDATION. THE DRAIN SHALL DISCHARGE INTO THE STREET OR MORTARDS. TILES TO BE BACK BUTTERED. -SIZE: 1/2" <br /> CURVED, OR ANGULAR SECTIONS INSTALLATION OF CERAMIC TILE. THIS SECTION IS NOT USED APPROVED DRAINAGE FACILITY. USE ONLY RIGID PIPE, FLEXIBLE PIPE WILL - INSTALLED PER MANUFACTURERS <br /> NO LENGTH-TO-WIDTH RATIO SHOULD EXCEED 2 '/2 TO 1 IN ANY GIVEN B. ANSI A136.1 -AMERICAN NATIONAL STANDARD FOR ORGANIC ADHESIVES NOT BE ALLOWED. RECOMMENDATIONS <br /> PANEL. FOR INSTALLATION OF CERAMIC TILE. DIVISION 26 - ELECTRICAL IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO TAKE PROPER - 1/2" SIZE FOR T-1/T-2 CORNERS ONLY. GC TO <br /> C. ASTM C 144-STANDARD SPECIFICATION FOR AGGREGATE FOR MASONRY SEALED CONCRETE SLAB COORDINATE CORNER SPEC FOR OTHER WALL <br /> • EROSION CONTROL MEASURES. THE CONTRACTOR SHALL BE FINISH CONDITIONS. <br /> FINISH TEXTURE AND COLOR SHALL BE AS APPROVED BY OWNER. MORTAR. <br /> SEE ELECTRICAL DRAWINGS FOR SPECIFIC INFORMATION RELATED TO RESPONSIBLE FOR PROPER SURFACE AND SUBSURFACE DRAINAGE OF <br /> • CLIMATE CONDITIONS: AIR TEMPERATURE MUST BE 40°F. MINIMUM AND D. ASTM C 150-STANDARD SPECIFICATION FOR PORTLAND CEMENT. ELECTRICAL REQUIREMENTS. THE SITE. SLOPE ALL FINISH GRADING AWAY FROM BUILDINGS, WALKS, "SALT& PEPPER" FINISH. REFERENCE SPECIFICATION <br /> RISING WHEN APPLYING CEMENT PLASTER OR EXTERIOR FINISH COAT. E. TCNA-TILE COUNCIL OF NORTH AMERICA, INC. HANDBOOK FOR CERAMIC, DRIVES OR DECKS AND PROVIDE CATCH BASINS WHERE REQUIRED. SECTIONS 033000 CAST-IN-PLACE CONCRETE AND 033536 7-11 #1043581 <br /> AIR TEMPERATURE MUST REMAIN ABOVE 40'F. FOR A MINIMUM OF 24 GLASS, AND STONE TILE INSTALLATION - LATEST EDITION 1. POLISHED CONCRETE FLOOR FINISH, BOTH PROVIDED BY WALL TILE EDGE <br /> HOURS. CONSULT NATIONAL WEATHER SERVICE BEFORE BEGINNING F. ISO 13007-INTERNATIONAL STANDARDS ORGANIZATION; CLASSIFICATION DIVISION 27 - COMMUNICATIONS FINISH GRADES SHALL BE HELD DOWN IN PLANTING AREAS. THE 7-ELEVEN AND DATED 02-26-2018 <br /> WORK. PROTECT CEMENT PLASTER AND EXTERIOR FINISH COAT FROM FOR GROUT AND ADHESIVES. CONTRACTOR SHALL PROVIDE AND INSTALL A 6" MINIMUM THICKNESS OF 1. INSTALLED PER MANUFACTURERS RECOMMENDATIONS <br /> UNEVEN AND EXCESSIVE EVAPORATION DURING HOT, DRY WEATHER. THIS SECTION IS NOT USED CLEAN SELECT TOP SOILS IN THESE AREAS. 2. TILE EDGE: <br /> • ALLOWABLE TOLERANCES: MAXIMUM DEVIATION FROM TRUE PLAN 1/8 1.4 SUBMITTALS TE-1 : <br /> INCH IN 10 FEET AS MEASURED BY STRAIGHT EDGE PLACED AT ANY A. SUBMIT UNDER PROVISIONS OF SECTION 01300. ROUGH GRADING FOR SLABS-ON-GRADE SHALL BE WITHIN 2/10TH OF ONE BASE -GENERAL: PROVIDED BY GC (USED WITH T-5) <br /> LOCATION ON SURFACE. B. PRODUCT DATA: MANUFACTURER'S TECHNICAL INFORMATION FOR EACH - MANUFACTURER: SCHLUTER <br /> • FIELD SAMPLE: A SAMPLE PANEL SHALL BE PREPARED APPROXIMATELY PRODUCT SPECIFIED. DIVISION 2H - ELECTRONIC SAFETY AND SECURITY FOOT, PLUS OR MINUS. - MODEL: SCHIENE E 80 EB <br /> 2 FEET BY 2 FEET. THIS SAMPLE PANEL WILL BE A SEPARATE PART OF C. SAMPLES: COLOR CHARTS FOR SELECTION OF GROUT. THIS SECTION IS NOT USED 1. VINYL BASE: "WITH 3/8" RADIUS <br /> • SITE GRADING SHALL BE WITHIN 5/10TH OF ONE FOOT, PLUS OR MINUS. B-1 -. ROPPE -4" &6"; COLOR"193 BLACK BROWN" - FINISH: BRUSHED STAINLESS STEEL 304 <br /> THE PROJECT. INSTALLATION SHALL NOT PROCEED UNTIL THE SAMPLE D. INSTALLATION INSTRUCTIONS: MANUFACTURERS PRINTED INSTRUCTIONS (USE ONLY 6" IF REQUIRED BY LOCAL CODE) -SIZE 5/16" DEEP; 118" HIGH <br /> PANEL IS ACCEPTED BY THE ARCHITECT AND OWNER. THE SAMPLE FOR EACH PRODUCT. TE-2 : <br /> ALL ROOF DRAINAGE SHALL BE PIPED IN A CLOSED PIPE SYSTEM TO <br /> SHALL SHOW COLOR, TEXTURE, AND WORKMANSHIP OF FINISHED WORK. - GENERAL: PROVIDED BY GC (USED WITH T-5 AT <br /> DIVISION 29-30 - UNASSIGNED STREET OR APPROVED DRAINAGE FACILITY(U.O.N.). 2. TILE BASE: <br /> THE SAMPLE PANEL SHALL REMAIN ON THE PROJECT FOR COMPARISON 1.5 DELIVERY, STORAGE AND HANDLING B-2 : SCHLUTER-AHKA(FOR USE WITH CONCRETE VAULT MAN DOOR) LU <br /> PURPOSES WITH THE ACTUAL WORK. A. DELIVER AND STORE PACKAGES MATERIALS IN ORIGINAL CONTAINERS WITH THIS SECTION IS NOT USED - MANUFACTURER: SCHLUTER w <br /> BUILDER SHALL PROVIDE LANDSCAPE DEVELOPMENT GUIDELINES TO FLOOR) <br /> • OTHER MATERIALS WHERE APPLICABLE: SEALS UNBROKEN AND LABELS INTACT UNTIL TIME OF USE. PREVENT - MODEL: SCHIENE STEP V/SS 60 EB II <br /> BUYER THAT SHALL INCLUDE INFORMATION ON SITE MAINTENANCE AND - 3/8" COVE BASE <br /> POLYSTYRENE BOARD AND ARCHITECTURAL MOLDINGS: ASTM C-578 DAMAGE OR CONTAMINATION TO MATERIALS BY WATER, FREEZING, - FINISH: BRUSHED STAINLESS STEEL 304 O <br /> DEVELOPMENT AND STATE SUCH ITEMS AS "IRRIGATION SYSTEM SHALL BE - 1x6 CORNER <br /> TYPE 1. NOMINAL 1 LB/C.F. CURED EXPANDED POLYSTYRENE. FLAME FOREIGN MATTER OR OTHER CAUSES. DESIGNED TO PREVENT SATURATION OF SOIL ADJACENT TO BUILDING". - 1x6 OUTSIDE CORNER -SIZE 5/16" DEEP; 118" HIGH <br /> SPREAD AND SMOKE DEVELOPMENT EQUAL TO OR LESS THAN 24 B. DO NOT USE FROZEN MATERIALS UNLESS SPECIFICALLY ALLOWED BY -AHKA 125 AE FOR T-1 AND T-2, AHKA 80 AE FOR V r ) U) <br /> AND 450 RESPECTIVELY PER ASTM E-84/UL LISTED. INSULATION MANUFACTURER. ALL UTILITIES UNLESS INDICATED OTHERWISE SHALL BE INSTALLED UNDER T-5 J <br /> BOARD SHALL CARRY THE SEAL OF THE RADCO TESTING AGENCY. C. DELIVER AND STORE MATERIALS ON SITE AT LEAST 24 HOURS BEFORE ROLL-A-SHADE WINDOW GLARE PROTECTION Z <br /> FABRIC: A BALANCED, OPEN WEAVE, GLASS FIBER FABRIC, COMPLYING WORK BEGINS. GROUND. THE CONTRACTOR SHALL BE RESPONSIBLE TO INSURE THAT ALL J <br /> WITH ASTM D1682, STANDARD MESH, AS RECOMMENDED FOR WRAPPING D. PROVIDE HEATED AND DRY STORAGE FACILITIES ON SITE. TRENCHING WITHIN BUILDING AREA SHALL BE BACKFILLED AND 3. GALVINIZ COVE BASE: WITH RADIUS 1. INSIDE MOUNT IS STANDARD. OUTSIDE MOUNT ONLY IF <br /> COMPACTED WITH STRUCTURAL SOILS MATERIAL FREE OF ANY ROCKS OR B-5 : SMOOTH PEBBLE TEXTURREE 4" COVE BASE CC .. <br /> POLYSTYRENE BOARD AND MOLDINGS. PRIMER/ADHESIVE MIXTURE: INSIDE MOUNT IS DISRUPTED BY SIGNAGE, ETC. G z <br /> OTHER SHARP OBJECTS WHICH MAY DAMAGE UNDERGROUND UTILITIES. AROUND INTERIOR PERIMETER OF WALK-IN <br /> A FIELD-MIXED BLEND OF STANDARD POLYMER-BASED PRIMER ADHESIVE 1.6 PROJECT CONDITIONS 2. FABRIC WILL BE MERMET 7510 CHARCOAL COCOA 10% <br /> AND PORTLAND CEMENT. FOR USE AS A PRIMER AND LEVELER OVER A. MAINTAIN ENVIRONMENTAL CONDITIONS AND PROTECT WORK DURING ANDCOOLER UNITS WITH BRONZE 3"TOP FASCIA AND STAINLESS STEEL w O <br /> • UNDERGROUND PIPING SHALL BE LAID TO A MINIMUM 24" DEPTH BELOW <br /> CEMENT PLASTER BROWN COAT AND FOR USE AS AN ADHESIVE FOR AFTER INSTALLATION TO COMPLY WITH REFERENCED STANDARDS AND CHAIN - BRONZE CHILD SAFETY TENSION DEVICE. <br /> FINISHED GRADE. WHEN UTILITIES ARE PLACED IN A COMMON TRENCH, NOTE: <br /> z 06 <br /> FABRIC AND POLYSTYRENE BOARD AND MOLDINGS. ACRYLIC RESIN MANUFACTURER'S PRINTED RECOMMENDATIONS. 3. ROLL-A-SHADE TECHS WILL MEASURE AND INSTALL. <br /> ALL UTILITIES SHALL MAINTAIN SEPARATIONS AND COVERAGE BOTH 1. VERIFY AHJ SCHLUTER COVER TRANSITION IS <br /> BONDING AGENT: BONSEL, TAMMSWAY, OR APPROVED EQUAL. FOR B. VENT TEMPORARY HEATERS TO EXTERIOR TO PREVENT DAMAGE TO VERTICALLY AND HORIZONTALLY, AS REQUIRED BY APPLICABLE CODES. ALLOWED, USE CERAMIC COVE BASE AS REQUIRED CONTACT: JENEVIE ABOUBAKARE > U <br /> USE ON CONCRETE OR MASONRY BEFORE APPLICATION OF CEMENT TILEWORK FROM CARBON DIOXIDE. TEL. (951)245-5077 x141 Q <br /> PLASTER. C. MAINTAIN TEMPERATURES AT NOT LESS THAN 50 DEG F (10 DEG C) IN TILED BY AHJ T BE APPROVED E ( 7-ELEVEN). JENEVIE.ABOUBARKARE@ROLLASHADE.COM O N <br /> ADD MIXTURES: NO ADD MIXTURES OR PLASTIC CEMENTS WILL BE AREAS DURING INSTALLATION AND FOR 7 DAYS AFTER COMPLETION, 2. VERIFY WITH AHJ VINYL BASE (B-1) IS ALLOWED, USE <br /> ALLOWED WITHOUT APPROVAL OF THE ARCHITECT. UNLESS HIGHER TEMPERATURES ARE REQUIRED BY REFERENCED ALT BASE AS REQUIRED BY AHJ. TOILER PAPER DISPENSER V z U) <br /> SYNTHETIC EXTERIOR FINISH COATING: A 100% PURE ACRYLIC RESIN INSTALLATION STANDARDS OR MANUFACTURER'S WRITTEN INSTRUCTIONS. 06 O <br /> BASED, TEXTURED, FACTORY-MIXED COATING HAVING INTEGRAL B-2892 SURFACE MOUNTED TWIN JUMBO TOILET TISSUE <br /> COLOR, FOR EXTERIOR USE. MINIMUM STANDARDS SHALL BE DRY-VIT DISPENSER O J <br /> SYSTEMS INC., OR APPROVED EQUAL. RETAIL INFORMATION SYSTEM (RIS) BACKBOARD <br /> • CURING: WET BASE AS NECESSARY BEFORE APPLICATION WITH FINE FOG PAINTING COUNTERTOPS <br /> SPRAY TO PRODUCE UNIFORM MOIST CONDITION. WHEN REQUIRED, 1. BACKBOARD SHALL BE BY U-TECK, MODEL 501082J-FRG <br /> APPLY BOND COAT TO CONCRETE BASE AND MOIST CURE FOR MINIMUM APPLICATION SYSTEMS AND MATERIALS SHALL COMPLY TO THE P.D.C.A. CONTACT: DEBRA WOLFE 1.AT POINT OF SALE LOCATIONS z <br /> OF 24 HOURS BEFORE APPLYING FIRST COAT OF CEMENT PLASTER. "ARCHITECTURAL SPECIFICATIONS MANUAL." TEL. (800)542-7011 -WILSONART COSMIC STRANDZ <br /> DO NOT APPLY BROWN COAT SOONER THAN 48 HOURS AFTER - MATTE FINISH 4941K-60 <br /> APPLICATION OF SCRATCH COAT. PAINTING SHALL BE INCLUDED, BUT NOT LIMITED TO THE FOLLOWING 2.AT COFFEE CAR LOCATION <br /> DO NOT APPLY CEMENT PLASTER FINISH COAT SOONER THAN 14 DAYS (U.O.N.): METAL STUDS -SILESTONE ALPINA WHITE <br /> AFTER APPLICATION OF BROWN COAT. ALL EXPOSED METAL. THIS INCLUDES FLASHING, SCUPPERS, GUTTERS, 3. AT BEVERAGE BAR AND FRONT COUNTER HOT FOOD <br /> INSPECT AND REPAIR BASE COATS BEFORE APPLICATION OF FINISH DOWNSPOUTS, LOUVERS, GATES, RAILINGS, ETC. SHEET METAL ROOF 1. CLARKDIETRICH METAL FRAMING SECTION <br /> COAT. VALLEYS, ROOF FLASHINGS AND VALLEYS SHALL BE PAINTED TO MATCH ICC#- ESR 1166P -STAINLESS STEEL <br /> CURE BASE COATS MINIMUM OF 48 HOURS AFTER APPLICATION. ROOFING MATERIAL. IAPMO#- ES-0189 <br /> MAINTAIN MOIST CONDITIONS BY FINE FOG SPRAY. ALL EXPOSED EXTERIOR WOOD SHALL BE PAINTED AND BACK PRIMED. <br /> CURE FINISH COAT FOR MINIMUM OF 7 DAYS. ALL PRECAST EXPOSED CONCRETE SHALL BE SEALED. <br /> • INSTALLATION AND FINISHING OF GYPSUM WALL BOARD SHALL COMPLY ALL DOORS AND FRAMES SHALL BE PAINTED, AFTER BEING HUNG AND <br /> FITTED, DOORS SHALL BE PAINTED ON ALL SIX SIDES. ALL GYPSUM <br /> WITH GA-216. BOARD SHALL BE PAINTED EXCEPT IN MECHANICAL CLOSETS. <br /> • FIRE-RESISTANCE RATINGS: WHERE GYPSUM WALLBOARD SYSTEMS ALL GYPSUM BOARD RECEIVING WALL COVERING SHALL BE PRIMED. ALL <br /> WITH FIRE-RESISTANCE RATINGS ARE INDICATED. EXPOSED INTERIOR WOOD SHALL BE PAINTED, INCLUDING CASEWORK <br /> WHERE INDICATED. <br /> PR#2 01 .06.2020 <br /> • ALLOWABLE TOLERANCES: GYPSUM WALLBOARD SURFACES SHALL HAVE SURFACES NOT TO BE PAINTED SHALL INCLUDE THE FOLLOWING (U.O.N.): <br /> NO MEASURABLE VARIATION IN ANY 2-FOOT DIRECTION AND A MAXIMUM PRE-FINISHED MATERIALS SUCH AS ACOUSTIC CEILING BOARD, BAKED <br /> VARIATION OF 1/8-INCH IN 10-FEET. SHIM WORK AS REQUIRED TO AND PORCELAIN ENAMEL, PLATED METALS, LAMINATED PLASTICS, <br /> COMPLY WITH SPECIFIED TOLERANCES. VINYLS, ETC. <br /> • FIRE-RATED GYPSUM WALLBOARD: ASTM C36, TYPE X, 5/8-INCH THICK, STAINLESS STEEL, BRONZE, AND ALUMINUM. REVISIONS <br /> WITH TAPERED AND WRAPPED LONG EDGES. DO NOT PAINT ANY MOVING PARTS OR OPERATING UNITS, MECHANICAL <br /> AND ELECTRICAL PARTS, SUCH AS VALVE AND DAMPER OPERATORS, <br /> • FIRE RATED WALLS, THROUGH PENETRATION FIRESTOP SYSTEMS & FIRE LINKAGES, SENSING DEVICES, MOTOR AND FAN SHAFTS. <br /> RESISTIVE JOINT SYSTEMS TO BE CONSTRUCTED IN ACCORDANCE WITH DO NOT PAINT OVER ANY CODE-REQUIRED LABELS, SUCH AS <br /> ASSEMBLIES LISTED BY UL, WARNOCK HERSEY/INTERTEK/ETL/SEMKO. UNDERWRITERS LABORATORIES AND FACTORY MUTUAL, OR ANY <br /> EQUIPMENT IDENTIFICATION,PERFORMANCE RATING, NAME, OR <br /> NOMENCLATURE PLATES. NEATLY MASK ALL SUCH ITEMS, AND REMOVE <br /> STANDARDS: <br /> INSTALLATION STANDARDS: ASTM C 840/GA 216/ASTM C 919. MASKING AT COMPLETION OF PAINTING. <br /> • ASTM C-11 FOR DEFINITIONS UNLESS OTHERWISE SCHEDULED, THE OWNER SHALL SELECT PAINT <br /> • ASTM C-754 GENERAL COMPONENTS. COLORS. <br /> • ANSI 118.9 CEMENT BACKER BOARD <br /> • ASTM C-1047 TRIM PAINT ALL METAL REGISTERS AND GRILLS TO MATCH ADJACENT SURFACES <br /> • ASTM C-475 JOINT TREATMENT MATERIALS (U.O.N.). <br /> • ALL PERIMETER CONDITIONS WHERE FIRE RATED GYP BOARD PAINT ALL GUTTERS TO MATCH FASCIA AND PAINT ALL DOWNSPOUTS AND <br /> ASSEMBLIES MEET OTHER CONSTRUCTION MUST BE CONSTRUCTED VENTS TO MATCH ADJACENT SURFACES (U.O.N.). <br /> USING A LISTED FIRE-RESISTIVE JOINT SYSTEM. <br /> • ALL PENETRATIONS THROUGH FIRE RATED GYP BOARD ASSEMBLIES <br /> MUST BE CONSTRUCTED USING A LISTED THROUGH PENETRATION <br /> FIRESTOP SYSTEM. <br /> • MOISTURE-RESISTANT GYPSUM BOARD: ASTM C630, TYPE X, 5/8-INCH <br /> THICK WITH TAPERED AND WRAPPED LONG EDGES. PROVIDE FOR <br /> EXPOSED AND CONCEALED LOCATIONS AT WALLS OF BATHROOMS, <br /> KITCHENS, AND OTHER WET SPACES; DO NOT USE ONCEILINGS. <br /> • SCREWS: ASTM C954 OR ASTM C1002. <br /> • METAL TRIM: PROVIDE SQUARE CORNER BEAD AND EDGE TRIM. <br /> • ACOUSTICAL SHEET SEALANT PAD: HARRY A. LOWRY&ASSOCIATES, <br /> 11176 PENROSE ST. SUN VALLEY, CALIFORNIA 91352. (818) 768-4661 OR <br /> EQUAL. <br /> • TEXTURING MATERIAL: U.S. GYPSUM "USG SPRAY TEXTURE FINISH" OR <br /> APPROVED EQUAL; MACHINE LIGHT"ORANGE PEEL FINISH". <br /> • INSTALLATION OF FASTENERS: <br /> FIRE-RATED PARTITIONS: INSTALL FASTENERS IN ACCORDANCE WITH <br /> CBC TABLE 721.1 (2) <br /> NON-FIRE-RATED PARTITIONS: INSTALL FASTENERS IN ACCORDANCE <br /> WITH CBC TABLE 2508.5 <br /> FIRE-RATED CEILINGS: INSTALL FASTENERS IN ACCORDANCE WITH <br /> CBCTABLE721.1 (3) AND GYPSUM ASSOCIATION "FIRE-RESISTANCE SEAL/SIGNATURE <br /> DESIGN MANUAL". <br /> NON-FIRE-RATED CEILINGS: INSTALL FASTENERS SPACED NOT MORE JOB NO. 1497.009 <br /> THAN 12-INCHES ON CENTER FOR SCREWS.INSTALL SCREWS USING <br /> POWERED SCREW GUNS WITH ADJUSTABLE SCREW-DEPTH CONTROL DRAWN WF <br /> HEAD. <br /> CHECK GM <br /> SPECIFICATIONS <br /> 0 <br /> 0 <br /> NSHEET <br /> 0 <br /> N <br /> O <br /> N <br /> CO <br /> G002 <br />