ORACLE #03164154 EF-1 ITEM #106
<br /> PROJECT: MODEL: TITY: ITEM NO:
<br /> I 3 1 1 1 1 • 1
<br /> Ei■ � 9 0 -1 13 1
<br /> s � —
<br /> R
<br /> 4'
<br /> Hn
<br /> 3
<br /> 2'
<br /> 1'
<br /> TS•1826.7 TS-1826.14 TS•1826.7.7 TS-1826.15 TS•1826.18 TS•1826.24 TS•1826.30
<br /> *__61W51_+ 4
<br /> 1D D
<br /> 1 o O
<br /> " TOP "Dn TOP
<br /> o 0 f1 0 0
<br /> DOOR SWING:180° LEFT:160°RIGHT:180°
<br /> ELECTRICAL DATA
<br /> CAPACITIES OF TRAYS I PANS; 4.5"Spacings are Standard[A] OVERALL EXTERIOR CLASS 100 TS-1 826-7 s TS 26-14 TS-1826-24 TS-18lit
<br /> 26.7.7
<br /> STANDARD CAPACITY, OPTIONAL CAPACITY; DIMENSIONS IN.�mm� TS-1826.18 TS-1826-30 Cavi,
<br /> MODEL @4.5"Spacings @3"Spacings lHei#Induces Casters) VOLTS 120 120 120
<br /> TRAYIPAN — o �, M TRAYIPAN =_ o „ M SHIP WT, WATTS 1300 1650 2100
<br /> NUMBER N N — SLIDES o x x x x HIGH DEEP WIDE NO. CASTER LBS. QUICK AMPS 10.8 13.8 17.5
<br /> SLIDES x K K x "H" "D" "W" DOORS SIZE JKG) ITEM HERTZ 50/60 50/60 50/60
<br /> PROVIDED � < < :2 REQUIRED a :2 Z2
<br /> FUnd�erCounter 5 r 5 5 10 5 10 7 r 2 r 7 7 14 7 14 32.5" 31' 26.5" 1 2„, 230 PHASE Single Single Single
<br /> P p ( p) (826) 887) (673) (104)10 10 20 10 20 36.5' 33.25” 54" 340 USA
<br /> 10 pr 14 pr (4 pr)14 14 28 14 28 (927) (845) (1372) 25" (154) 5-15P 5-15P* 5-20P*
<br /> • . . 10 pr 10 10 20 10 20 14 pr (4 pr) 14 14 28 14 28 ss.s 33.25' 30.5" 2 5" 380) PLUG
<br /> Split Cavity 5 ea Cavity (1765) (845) (775) Dutch (172
<br /> CANADA 5-20P 5-30P
<br /> TS•181615 10 pr 1 10 20 10 20 15 pr (5 pr) 15 15 30 15 30 sos" 33.25' 30.5" 1 5„ 310 QUICK 5-15P
<br /> (1537) (845) (775) (141) ITEM VOLTS 220-240 220-240 220-240
<br /> TS-1826-18 12 pr 12 12 24 12 24 18 pr (6 pr)18 18 36 18 36 69.5 33.25' 30.5• 1 5„ 365 * WATTS 1538 1954 2480
<br /> (1765) (845) (775) (166) AMPS 6.4 8.1 10.3
<br /> TS•1826.24 16 pr 16 16 32 16 32 24 pr (8 pr) 24 24 48 24 48 54' 33.25' 54' 2 5„ 450 HERTZ 50/60 50/60 50/60
<br /> (1372) (845) (1372) (204)
<br /> PHASE Single Single Single
<br /> TS•1826 30 40 pr 20 20 40 20 40 130 pr(10 pr 30 30 60,30 60 61.5" 33.25' S4' 2 6" 465
<br /> (1562) (845) (1372) (211) PLUG0 0 0
<br /> [A] Tray slides accommodate:(1)18"x 26",(1)12"x 20",(2)14'x 18",(1)GN 1/1 trays/pans. USA
<br /> 6-15P 6-15P 615P
<br /> Uprights punched on 1.5" (114 centers.Tray slides are adjustable.Number of tray slides are listed above.
<br /> Standard spacings are 4.5""(114mm). PLUG
<br /> TS-1826-7-7 Split Cavity provides 2 compartments,each with separate controls;5 pair of tray slides are provided in each compartment. CANADA
<br /> TS-1826 models are available with the Pass-thru Door[add"P"],See-thru Lexan Door[add"L"]and Dutch Doors[add"D"] 6 15P 6 15P 6 15P
<br /> optional accessories.Note:Dutch Doors are 2 half size doors only available on full-size models.
<br /> *TS-1826-7 is an undercounter model.It is provided without a bumper and is provided with all swivel casters and with form grip flush in wall hand grips recess *Dedicated circuit.
<br /> mounted on each side of the unit.Bumper can be added as an optional accessory.
<br /> CONSTRUCTION.Heliarc welded,single DOORS AND LATCHES.Flush mounted, TRAY SLIDES.Welded rod-style tray slides are ELECTRICAL CHARACTERISTICS. OPTIONAL ACCESSORIES
<br /> unit construction of stainless steel;20 gauge stainless steel insulated doors.High temperature nickel plated for greater durability and sanitation. 3 wiregrounded tri-directional power cord and plug, ELECTRIC
<br /> polished exterior,22 gauge stainless steel interior gasket sealed;gasket shall be cabinet mounted. Fully adjustable/removable and designed to give rear mounted for safety.See electrical data chart ❑ Electronic Controls
<br /> with easy-to-clean coved corners.Welded tubular Each door shall have two(2)heavy-duty secure bottom tray support.Removable stainless above for amperage and receptacle configuration. ❑ 1500 or 2000 watt element
<br /> base frame shall be 1"square,heavy gauge edgemount die cast hinges.Door latch shall be steel uprights shall be punched on 1.5"spacings, See electrical chart for models that require a ❑ 220 volt,50/60 Hz,single phase
<br /> stainless steel tubing,with 10 gauge stainless edgemounted,full grip,and positive closing.The o.c.,for easy tray adjustment,and shall easily lift dedicated circuit ❑ Heat retention battery
<br /> steel reinforcing plates at corners. hinge and latch mountings are reinforced with off heavy-duty stainless steel brackets without the INSTALLATION.Unit should not be installed in an DOORS
<br /> INSULATION."Ultra-Guard"UG-26 high density stainless steel backing plates.TS-1826-7-7P, use of tools for cleaning.Tray slides accommodate: area where adverse environmental ❑ Dutch doors
<br /> fiberglass insulation throughout;top,back,bottom, TS-1826-18P,TS-1826-30,and TS-1826-30P (1)18"x 26',(2)12'x 20",(1)14"x 18",(1)GN conditions are present. ❑ See-thru Lexan door
<br /> sides,and door(s), are provided standard with magnetic edgemount 1/1 trays/pans per pair of tray slides ❑ Key locking door latch
<br /> HANDLES.Heavy-duty push bar handles,solid door latches. HEATING SYSTEM I CONTROLS.Patented FWE products may be covered under one or more ❑ Paddle latch
<br /> formed 1"x.375"thick;mounted at each end of CASTERS.Maintenance free polyurethane tire built-in"Humi-Temp"system shall include an of the following U.S.patents:288,299;238,300;3,9 ❑ Magnetic latch
<br /> unit.Mountings reinforced with casters in a configuration of two(2)rigid and Incoloy nickel-chromium alloy heating element and 52,609;4,192,991.All rights reserved.All ❑ Padlocking transport latch
<br /> to change without notice.
<br /> stainless steel channel.TS-1826-7 is two(2)swivel with brake.Casters shall have a Hi-Temp,self-lubricated,impedance protected specifications subjectErrors subject to correction. ❑ Left hand door hinging
<br /> standard with form grip flush-in-wall hand grips reinforced yoke mounted to 10 gauge caster plate. fan-cooled blower motor.Cabinet shall have ©17 Food Warming Equipment Company,Inc. (single door models)
<br /> recess mounted on each side of unit. The caster mounting plate shall be secured to a 10 humidifying chamber and drawer style baffled R.17.02 CASTERS
<br /> BUMPER.Solid 1.5"wide continuous gauge stainless steel reinforcing stress plate via humidifier pan.Both shall be stainless steel and ❑ All swivel or larger casters
<br /> wraparound aluminum channel,bolted to frame, welded in place stainless steel studs.The removable.Controls shall be upfront,recessed ❑ Floodock(requires 6"casters)
<br /> with snap-in,non-marking vinyl cushion.Full reinforcing stress plates shall be welded to the and shall include a full range thermostat adjustablePAS CINGS
<br /> perimeter bumper extends beyond doors,handles, heavy gauge tubular frame of the unit. to actual temperature.Thermostat shall include ❑ Fixed rack assembly
<br /> etc.,for added protection.Shall be continuous, temperature scale marked in ten degree ❑ Extra tray slides
<br /> with comer cut-outs to facilitate cleaning.TS-1826- increments(F/C)from 90"to 190T(32"to 88"C). ❑ Shelves
<br /> 7 is standard without a bumper An operational range thermometer,power supply EXTRAS
<br /> light,thermostat cycling light,and 20 amp ON/OFF ❑ Security packages
<br /> switch are also included. ❑ X-factor frame
<br /> ❑ Tubular stainless steel push handles
<br /> ❑ Cord winder bracket
<br /> ❑ Top bumper
<br /> FOOD WARMING EQUIPMENT COMPANY, INC. 800.222-4393 COOK I HOLD I TRANSPORT I SERVE I REFRIGERATION I BARS
<br /> 5599 HWY.31 W. Portland,TN 37148 @ © ()fwe.com ® ` 117 © OI815.459.7500 Fax:815.459.7989 sales www.FWE.COm rube k U
<br />
|