Laserfiche WebLink
28. Access to Water Closets and Sanitary Facilities 31. General Toilet Room Fixtures and Accessories <br /> Entry to Sanitary Facilities: General for both multiple and single (2016 CBC Sections 11 B-305, 11 B-306, 11 B-603 - 11 B-606, 11 B- <br /> accommodations. (2016 CBC Section 1113-703.7) 609, 11 B-605) <br /> (SEE NOTE:(NOTE 31 /G1.3) AND DETAIL:(2/G1.3) ) (See details: (2/G1.2) , (1 /G1.3), (3/G1.3) , (8/G1.2), (5/G1.3) ) <br /> A. Signage: A. Grab Bars (Sections 11 B-604.5 & 11 B-609 & 11 B-604.8.1.1.3, <br /> A.1. Men's room: equilateral triangle 1/4" thick, edges 12" 1113-604.5.11, 111113-604.5.2) <br /> long, & a vertex pointing upward (11 B-703.7.2.6.1) A.1. Height: 33" min.-36" max. above and parallel to finished <br /> A.2. Women's room: Circle 12" diameter, 1/4" thick. (1113- floor measured to the top of the gripping surface. <br /> 703.7.2.6.2) (11 B-609.4) <br /> A.3. Unisex room: 1/4" thick triangle within and superimposed A.2. Rear grab bar at water closet length: 36" minimum- <br /> on 12" diameter, 1/4" circle. (11B-703.7.2.6.3) extend from water closet centerline 12" minimum in one <br /> A.4. Location: 58" min.-60" max. above floor to center and direction and 24" minimum in other direction. 5865 Owens Drive <br /> centered on door. (11 B-703.7.2.6) A.3. Side grab bar at water closet: <br /> Pleasanton, CA 94588 <br /> A.5. Contrasting color with respect to the door, either light on A.3.1. Length: 42" minimum 925-251-7200 <br /> a dark background or dark on a light background. A.3.2. Position: Front end located at least 24 In front of the <br /> (Unisex circle symbol shall be contrasting symbol.) water closet and 54" minimum from rear wall. Rear end <br /> A.6. Tactile Characters on signs shall be located 48" min. 12" maximum from rear wall. <br /> A.3.3. 3" maximum projection into required clear floor space. <br /> A.F.F. or ground surface, measur�1-I/fG1.3)he baseline to A.4. Gripping surface diameter: 1 1/4" to 2" or an equivalent <br /> the lowest braille cells. See Detail. surface. <br /> (11 B-703.4.1) gripping <br /> A.5. Space between wall and grab bar: 1 1/2". <br /> A.7. International symbol of accessibility shall be white figure <br /> A.6. Grab bars shall not rotate within their fittings. <br /> on blue background (1113-703.7.2.1) A.7. Grab bars and adjacent surfaces shall not have any <br /> B. Doorways: 32" clear opening width. sharp or abrasive elements. <br /> C. Level and clear area on swing side of door: 60" measured at 90 A.8. Edge radius: 1/8" minimum. <br /> deg. to door in closed position extending 18" beyond strike A.9. Grab bars and seats: Bending stress, direct shear stress, <br /> edge (24" at exterior doors). tensile stress, torsion stress must support an application <br /> D. Level and clear area opposite swing side of door: 48" measured CONSULTANT <br /> of 250 Ib. point load. <br /> at 90 degrees to door in closed position. <br /> B. Urinals (11 B-605) (Figure 11 B-605.2) <br /> 13.1. Height of rim: 17" A.F.F, maximum. <br /> 30. Single Accommodation Toilet Rooms 13.2. Rim projection: 13 1/2" deep minimum measured from the <br /> Definition: A room with no more than one of each type of sanitary outer face of the urinal rim to the back of the fixture. <br /> fixture, is intended for use by only one person at a time, has no B.3. Clear space in front of fixture 30" wide x 48" deep for <br /> partition around the toilet and has a door that can be locked on front approach. <br /> NIP <br /> the inside by the room occupant. B.4. Flush control: operable with one hand without tight <br /> (2016 CBC Section 11 B-604.2 and Figure 11 13-1A) (See grasping, pinching or twisting of wrist; mounted 44" max. ELEVEn <br /> (NOTE 31 /G1.3)AND Details (2/G1.3) above floor; 51b.-force max. to operate. Electronic <br /> automatic flushing controls are acceptable and <br /> A. Space inside: room for a wheelchair 30" x 48" to enter and preferable. (11 B-605.4) <br /> close door. (11 B-305.5) B.5. Fixtures placed in alcoves to comply with Section 1113- <br /> B. 60" diameter circle or T-shaped space (11 B-304.3.1). No door 305.7 and Figure 1113-305.7.1. (See detail) <br /> shall encroach more 12" into this space. (11 B-304.3.2) C. Lavatories (Section 11 B-606) 7-11 #1043581 <br /> C. 60" min. wide & 48" min. deep space provided in front of the C.1. All accessible lavatories: 18" minimum from center line of <br /> water closet. (Figure 11B-604.3.1) fixture to any wall, 17" minimum in horizontal depth. <br /> D. At the other side of the water closet, from the centerline of the C.2. Rim or counter height: 34" maximum above finished floor. <br /> water closet to the wall: 17"-18". (Figure 11B-604.2) C.3. Clearance under front apron: 29" from floor, reducing to <br /> E. Clear space in front of water closet: 48". (11B-604.3.1) 27" height at a point 8" back from front edge. <br /> F. Grab bars: (See item 4A). (11 B-306.3.3. EX1) <br /> G. Miscellaneous fixture requirements. (See item 4). CA. Clear floor space of 30" wide x 48" deep in front of fixture <br /> G.1 Privacy latch at entrance to allow forward approach and shall extend 19" maximum <br /> H. Lavatory: 18" minimum to wall from center of lavatory. into knee and toe space underneath the lavatory. <br /> I. Doors shall not swing into clear floor space required for any (11 B-606.2) <br /> fixture. (11 B-404 & 11 B-604.8.1.2) C.5. Toe clearance: 9" high extending to 19" maximum under I <br /> lavatory. (11 B 306.2.2) z W <br /> C.6. Hot water and drain pipes insulated or covered, with no <br /> sharp or abrasive surfaces under lavatories. (11 B-606.5) O <br /> C.7. Faucet controls: �^ <br /> C.7.1. Operable with one hand without tight grasping, pinching or V J Z Q <br /> twisting of the wrist. J" Q (� <br /> C.7.2. 5 Ibf maximum to activate controls. 48MIN. TYP.TOILET MIRROR CC <br /> C.7.3. Self-closing valves if faucet remains open at least 10 ROOM ACCESSORY LAV. G Z <br /> seconds. (11B-606.4) MOUNTING o COVER OR w 0 <br /> D. Water closets (Section 11 B-604) X INSULATE X06 <br /> D.1. Height of seat: 17" to 19" above floor to top of 2" max. J EXPOSED Z z Q <br /> height seat. (11 B-604.2) PIPES No >Q O <br /> Flush control: operable with one hand without tight N N > ~ <br /> grasping, pinching or twisting of the wrist; located on wide 19"MIN. 6" MAX. TOE Z (n <br /> side of fixture areas; 44" max. above floor; 5 Ibf max. to CLEARANCE 17" CLEARANCE06 0 <br /> operate. (11 B-604.6) 30" MIN. (n <br /> E. Toilet tissue dispensers: within 7-9" of the front edge of water M O J <br /> closet seat; below grab bar 19" min. above finished floor. N IF - - - - <br /> i _-----REQUIRED NOTE: IF A MINIMUM 9"HT. � <br /> (11 B-604.7) z I CLEAR SPACE OF TOE CLEARANCE IS <br /> F. Towel, sanitary napkin, waste receptacles and similar Z I 18" MIN. PROVIDED,A MAXIMUM OF 6" Z <br /> dispensing and disposal fixtures: one of each to be mountedI X z OF THE 48"OF CLEAR FLOOR <br /> with operable parts including coin slots within 40" of finished , SPACE REQUIRED AT THE <br /> FIXTURE MAY J <br /> floor. (11B-603.5) L -°- � � THE TOE SPACE.TENDINTO <br /> G. Mirror: 40" maximum from finish floor to bottom edge of <br /> reflecting surface. (Mirrors other than above lavatories or THIS DIAGRAM ILLUSTRATES THE SPECIFIC REQUIREMENT OF THE ACCESSIBILITY REGULATIONS AND IS <br /> countertops shall be at 35" max.) (11 B-603.3) INTENDED ONLY AS AN AID FOR BUILDING DESIGN AND CONSTRUCTION. THIS DIAGRAM ILLUSTRATES THE SPECIFIC <br /> KNEE CLEARANCE SPACE SHALL EXTEND 19"DEEP MIN.AT 27"ABOVE FINISH FLOOR OR GROUND WITH 30"X48" REQUIREMENT OF THE ACCESSIBILITY REGULATIONS <br /> GROUND CLEAR SPACE. AND IS ONLY AS AN AID FOR BUILDING DESIGN AND <br /> CONSTRUCTION. <br /> SCALE: 1/2"=V-0" SCALE: 1/4"=V-0" 2016 CBC 11B-606 <br /> KP9 S%Es&9.dWgLAVATORIES 6 ACCESSIBLE LAVATORIES 3 <br /> 16 CBC FIGURE 11B-308.2.1&11B-308.2.2 _ P R#2 01 .06.2020 <br /> LIGHT COPY ON DARK BACKGROUND OR DARK COPY ON LIGHT BACKGROUND LETTERING_�D 1/32" <br /> 6"U.O.N. 6"U.O.N. 6"U.O.N. ' <br /> i <br /> UPPER CASE SANS-4RIF <br /> � EDGES �� <br /> 0 0 0 0 SHALL BE �\ Ax REVISIONS <br /> �7i ROUNDED, <br /> `� +60"MA . CHAMFERED \i <br /> WALL _ ` - <br /> i OR EASED--A- <br /> 1 <br /> ASED <br /> UNISEX WOMEN MEN +48"MIN! 7 °° 1/8"MIN. <br /> 11/2" - - - - - - A - - RADIUS <br /> i <br /> WALL MOUNTED SIGNAGE(TYP.) �� i <br /> ' CORRESPONDING i <br /> WALL SIGNAGE TO BE MOUNTED AT 48"MIN.TO BASELINE OF LOWEST LINE OFA CONTRACTED <br /> BRAILLE&60"MAX TO BASELINE OF HIGHEST LINE OF RAISED CHARACTER ON LATCH ` GRADE 2 BRAILLE <br /> 11/4"TO 1 112" SIDE OF DOOR W/CLEAR FLOOR SPACE OF 18". - <br /> NOMINAL THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE CIRCLE SYMBOL, <br /> DIAMETER EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT 9" F.0-WALL DOOR MOUNTED <br /> SIGNAGE WITHIN 1"OF <br /> ODOUND. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE 9 VERTICAL CENTERLINE <br /> THER LIGHT ON A DARK BACKGROUND OR DARK ON A LIG T E DOOR <br /> UND <br /> 0 -\ - - <br /> WOMEN MEN EQ. EQ.THIS DIAGRAM ILLUSTRATES THE SPECIFIC X <br /> REQUIREMENT OF THE ACCESSIBILITY REGULATIONS ' 66Q <br /> AND IS INTENDED ONLY AS AN AID FOR BUILDING IGHT LETTERS,TYP.U.O.N. , <br /> DESIGN AND CONSTRUCTION. SHAPES SHALL BE 1/4"THICK,TYP. <br /> DOOR MOUNTED SIGNAGE(TYP.) <br /> NOTE:LETTERING NOT REQUIRED ON DOOR THIS DIAGRAM ILLUSTRATES THE SPECIFIC REQUIREMENT <br /> MOUNTED SIGNAGE. OF THE ACCESSIBILITY REGULATIONS AND IS ONLY AS AN <br /> SCALE: 3"=1'-0" 2016 CBC FIGURE 11B-609.3 SCALE: 114"=V-0" AID FOR BUILDING DESIGN AND CONSTRUCTION. 2016 CBC 11B-703.7.2.6 <br /> SECTION THROUGH TYP. GRAB BAR 5 RESTROOM SIGNAGE 2 <br /> 1/2"RADIUS, .090"ALUM.SHEET CONFORMING WITH <br /> TYPICAL STRENGTH AND DURABILITY PROPERTIES 36" MIN. <br /> SPECIFIED IN ASTM 8209 FOR 5005-1-115. <br /> ck,� ATTACH TO STEEL PIPE WITH(2)1/4"DIA. 60"MIN. CENTERLINE OF 12"q 24" <br /> J TAMPERPROOF BOLTS. AREA OF SIGN TO FIXTURE <br /> PARKING 17"-18" MIN. MIN. <br /> ONLY BE 70 SQ.IN.MINIMUM.SIGN SHALL BE 18„ REAR GRAB BAR <br /> REFLECTORIZED. A ALLOWED AT 36" o <br /> 0 WHITE LETTERS AND SYMBOLS ON BLUE , 12. 24. CLR, A.F.F.AT c, TRANSFER <br /> z= BACKGROUND WORDED:"PARKING ONLY". FLUSH ACTIVATOR ch SIDE <br /> MIN. MIN. TANK-TYPE TOILET <br /> a PROVIDE ADDITIONAL SIGN OR ADDITIONAL ON WIDE SIDE <br /> 0 Z LANGUAGE BELOW SYMBOL OF <br /> o = ACCESSIBILITY STATING"MINIMUM FINE$250" REAR WALL ELEVATION 1 -18 SEE 2013 CBC <br /> Co <br /> _ 11B-604.2 SEAL/SIGNATURE <br /> 0o PROVIDE ADDITIONAL SIGN OR ADDITIONAL \ \` JOB NO. 1497.009 <br /> QLANGUAGE BELOW SYMBOL OF \ CLEARANCE <br /> U) 0 ACCESSIBILITY STATING"VAN-ACCESSIBLE"AT VAN N 601' <br /> w z ACCESSIBLE STALLS. 54" MIN. DRAWN IG <br /> z co 2"DIA.GALVANIZED STEEL PIPE C� 12". <br /> �Q 42" MIN. MAX. CHECK SF <br /> 00 <br /> Q - FINISHED SURFACE d _ �' GRAB BAR <br /> 0 CbE 0 0°0000 0 " <br /> 00 Cf) 8"DIA.CONCRETE SURROUND AROUND 7"-9" Q THIS DIAGRAM ACCESSIBILITY <br /> UJ <br /> u_ PIPE COLUMN 18" 32"MIN. ALL <br /> DISPENSERS Q ILLUSTRATES THE <br /> U_ z GRAVEL FILL MIN. CLR. ® < REQUIREMENT OF THECIFIC NOTES CSC DIAGRAMS <br /> o ZN o HIGHEST a0 ERABLEPART 6, _ 177� <br /> co ACCESSIBILITY (CBC 1 1 B <br /> NOTES: z �, <br /> SIGN TO BE CENTERED AT THE INTERIOR ;� °' a REGULATIONS AND IS <br /> INTENDED ONLY AS AN AID <br /> co UjEND OF THE PARKING STALL <br /> C\1 THIS DIAGRAM ILLUSTRATES THE SPECIFIC 0 FOR BUILDING DESIGN AND <br /> �o 0 o REQUIREMENT OF THE ACCESSIBILITY ~ CONSTRUCTION. <br /> PROVIDE ONE SIGN PER ACCESSSIBLE STALL SHEET <br /> REGULATIONS AND IS INTENDED ONLY AS AN SIDE WALL <br /> SIGNS MAY BE CENTERED ON WALL AT THE AID FOR BUILDING DESIGN AND CONSTRUCTION. ELEVATION <br /> oSCALE: INTERIOR OF PARKING SPACE SCALE: 1/4"=V-0" 2016 CBC FIGURE 11B-604.3.2 SCALE: 114"=V-0" 2016 CBC FIGURES 11B-604.5.1&11B-604.5.2 <br /> NG1 03 <br /> co PARKING STALL SIGNAGE 7 SINGLE-ACCOMODATION TOILET 4 ACCESSIBLE TOILET ELEVATION 1 <br />