Laserfiche WebLink
OCCUPANCY SCHEDULE PLUMBING OCCUPANCY CALCULATION PLUMBING FACILITIES CALCULATION CODE ANALYSIS NOTES <br /> RM # NAME AREA OCCUPANCY TYPE LOAD FACTOR OCCUPANT LOAD OCCUPANCY PLUMBING PLUMBING OCCUPANT <br /> RM# NAME AREA TOTAL OCCUPANTS SEE CIVIL DRAWINGS BY KIER&WRIGHT (SUBMIT <br /> 101 MERCHANDISE 1535 SF Mercantile - Basement and 60 26 GROUP LOAD FACTOR REQUIRED PROVIDED SEPARATELY FOR SITE ACCESSIBILITY <br /> Grade Floor PLUMBING FIXTURE > <br /> MEN WOMEN TOTAL MEN WOMEN TOTAL INFORMATION 1 <br /> 102 SALES 284 SF Kitchens, Commercial 200 2 101 MERCHANDISE 1535 SF M 200 SF 8 OCCUPANTS 8 8 16 - - - ALL ENTRANCES/EXITS AT BUILDING SHALL BE <br /> 103 OFFICE 43 SF Business Area 100 1 102 SALES 284 SF M 200 SF 2 WATER CLOSETS 1 1 2 1 1 2 MADE ACCESSIBLE PER CBC CHAPTER 11 B <br /> 104 BACKROOM 305 SF Kitchens, Commercial 200 2 103 OFFICE 43 SF B 200 SF 1 URINALS 0 - 0 0 - 0 WHEELCHAIR LIFTS AT STAGE SHALL BE PROVIDED <br /> 105 WOMEN'S 56 SF (none) 104 BACKROOM 305 SF M 200 SF 2 LAVATORIES 1 1 2 1 1 2 WITH EMERGENCY BACK-UP POWER TO MAINTAIN AN <br /> ACCESSIBLE MEANS OF EGRESS IN THE EVENT OF A <br /> 106 MEN'S 53 SF (none) 105 WOMEN'S 56 SF POWER OUTAGE PER CBC 1007.2 & 111613.2. 5865 Owens Drive <br /> 107 ELEC. 37 SF Storage (Accessory) 300 1 106 MEN'S 53 SF Pleasanton, CA 94588 <br /> 108 FREEZER 20 SF Storage 300 1 107 ELEC. 37 SF S 5000 SF 0 925-251-7200 <br /> 109 ICE 22 SF Storage 300 1 108 FREEZER 20 SF <br /> 110 COOLER VAULT 326 SF Mercantile - Storage, Stock, 300 2 109 ICE 22 SF <br /> Shipping 110 COOLER VAULT 326 SF M 200 SF 2 CODE ANALYSIS SYMBOLS <br /> 111 TRASH ENCLOSURE 189 SF (none) 111 TRASH ENCLOSURE 1 189 SF <br /> Grand total 36 TOTAL PLUMBING OCCUPANTS 15 <br /> BUILDING CODE ANALYSIS 1-HOUR WALL CONSTRUCTION PER CBC TABLE <br /> 720.1 (2)- ITEM #14-1.3 <br /> (References in parenthesis are to CBC U.O.N.) ® m EXIT SIGN, S.E.D. <br /> PROJECT: FE SEMI RECESSED FIRE EXTINGUISHER CABINET <br /> AND EXTINGUISHER (2A:10B:C)SEE <br /> 7-ELEVEN AT 1 ON &26 N WILSON WY SPECIFICATIONS. EXTINGUISHERS SHALL BE CONSULTANT <br /> MOUNTED ON THE WALL OR IN CABINETS, SUCH <br /> 10 N & 26 N WILSON WAY, THAT THE TOP OF THE EXTINGUISHER IS NO <br /> STOCKTON, CA 95205 MORE THAN FIVE(5) FEET ABOVE FLOOR LEVEL. <br /> EXTINGUISHER SHALL BE COMMERCIAL GRADE, <br /> CURRENTLY TAGGED, OR HAVE <br /> APN: MANUFACTURER DATE CLEARLY MARKED ON <br /> 10 N WILSON WAY 153-040-260-000: 100 THE EXTINGUISHER <br /> r 26 N WILSON WAY 153-040-170-000: OCCUPANCY EXITING LOAD (ARROW INDICATES <br /> DIRECTION OF TRAVEL) <br /> O0.20X20 4"<36",OK OCCUPANCY CLASSIFICATION: ALLOWABLE SF PER OCCUPANT ELEvEn <br /> REQUIRED DOOR WIDTH (� J) <br /> KB = (PER CBC TABLE 1004.1.1) <br /> GROUP: M 200 SF/OCC <br /> 1 LLIN <br /> OCCUPANTLOAD <br /> ELEC. 20 <br /> NO SEPARATION IS REQUIRED BETWEEN PRIMARY AND 1 EXIT <br /> — — ° O // o ACCESSORY USE AREAS PER CBC 508.2.4 AND TABLE 508.4 (PERNUMCB OF EXITS REQUIRED <br /> 107 30/2+5=20) <br /> �■� (PER CBC 1015) 7-11 #1043581 <br /> 300 SF/OCC. I BACKROOM / I TYPE OF CONSTRUCTION: (Table 601) KNOX BOX UNIT PER STOCKTON FIRE DISTRICT <br /> STANDARDS FOR CITY OF STOCKTON. BOX <br /> 00_4 •104 L / _J BUILDING VB SHALL BE LOCATED ON THE EXTERIOR, RIGHT <br /> 305 SF SIDE OF THE DOOR, BETWEEN FIVE AND SIX <br /> SPRINKLERS: NO FEET ABOVE GROUND. PROVIDE MASTER KEYS <br /> _ _ I 0 200 SF/OCC. AND ACCESS CONTROL CARDS TO OBTAIN <br /> I _ — _ F2 I / FIRE-RESISTANCE RATING: (TableLF 601, Table 602) ACCESS TO ALL AREAS WITHIN THE BUILDING. <br /> IN ADDITION, PROVIDE KEYS NECESSARY TO <br /> / I OPERATE FIRE ALARM CONTROL PANELS, <br /> WOMEN'S <br /> /' 1 I EXTERIOR BEARING WALL NR ANNUNCIATORS, RESET OF ALARM DEVICES <br /> OFFICE LOCKS FOR SPRINKLER CONTROL VALVES, PIV, <br /> ALLOWABLE BUILDING HEIGHT: Sec. 504 & Table 503 BACK FLOW, ETC. CONTACT THE FIRE Lli <br /> MEN'S // I 43 SF ( ) DISTRICT FOR APPLICATION AND PURCHASE. LJ.1 <br /> Ecl — _ / MAXIMUM STORIES: 1CC � <br /> (2+1) <br /> / � � L 100 SF OCC. MAXIMUM HEIGHT: 40' O TACTILE EXIT SIGNAGE PER CBC 1011.3 O <br /> O / 1 EXIT SHALL BE IDENTIFIED WITH THE WORD <br /> FE I —3 r — — — I "EXIT"; RE: 10/G1.1 V ! U)I ACTUAL BUILDING HEIGHT: J z Q <br /> STORIES: 1 ###g SSIGN: "THIS POERSONSA MAXIMUM <br /> PER OCC1 UP NCY CCQ V <br /> CIES CIG'S ITP OTP HEIGHT: 24'-0" #- NUMBER OF OCCUPANTS G z <br /> 1,71 O <br /> ir > J (3+2) / ALLOWABLE AREAS FACTOR: TABLE 506.2 MOUNT AT 7'-0" (U.O.N) VERIFY LOCATION LLI 0 t I ® SALES 200 SF/OCC. / � I I WITH ARCHITECT. z <br /> �I /'/ MAXIMUM TABULATED AREA PER STORY: 9,000 SF (ANSUL) COMMERCIAL COOKING HOOD Q <br /> — �— • 2V* 284 SF 1 MANUAL FIRE PROTECTION SYSTEM O <br /> .4 (1 OPERATION PER CBC 904.11.1 AND 904.2.1. <br /> s° ACTUAL AREAS: SEE HOOD MANUFACTURER'S DRAWINGS z U) <br /> 0 0 FOR ADDITIONAL INFORMATION. <br /> °2io =`c�i� FIRST FLOOR: 2,993 SF O <br /> _E1sr� // ❑ X11 PANIC DOOR TO BE EQUIPPED WITH PANIC J <br /> I1111 4-J <br /> �° — — — TOTAL BUILDING AREA: 2,993 SF < 9,000 SF (COMPLIES) HARDWARE - HARDWARE SCHEDULE FOR - <br /> - REQUIRED DOOR WIDTH MORE INFORMATION N <br /> / 0.2X15=T<79",0KI z <br /> O I MAX DIAGONAL=78'-0" / C <br /> 78'-0"/3=26-0"(MIN.EXIT / MERCHANDISETO KB FR FIRE RISER <br /> O I SEPARATION) / 101 15 <br /> EXIT ACCESS TRAVEL: 1535 SF (30/2=15) — �— — — MAXIMUM EXIT ACCESS TRAVEL <br /> DISTANCE-58'-10"<200' / r <br /> ® I 60 SF/OCC. <br /> (COMPLIES PER CBC 1016.2) / I — <br /> O I / 26 <br /> ®§ <br /> PR#2 01 .06.2020 <br /> (O I E10 I / <br /> O <br /> / I s <br /> REVISIONS <br /> JAN <br /> — I I <br /> O 0 / <br /> I <br /> I � I <br /> FREEZER I <br /> 108 I /,/ I <br /> 20 SF 1 I 'E <br /> 300 SF/OCC. <br /> QEXIT ACCESS TRAVEL: <br /> J I / DISTANCE-60'-5"<200' <br /> / (COMPLIES PER CBC 1016.2) <br /> > - - - - -1- - - >- - - - - - - - - >- - - - - - - - - � - � <br /> 1 / <br /> ICE /r — — — — — — — — — — — — _T 2 <br /> 22 SF <br /> 109 /' I II II II II II II II II II II II I <br /> 300 SF/OCC. <br /> ❑ COOLER 300 SF/OCC. <br /> VAULT LL] <br /> / <br /> 326S <br /> ❑ ❑ <br /> SEAL/SIGNATURE <br /> JOB NO. 1497.009 <br /> DRAWN JK <br /> CHECK GM <br /> EGRESS PLAN <br /> CD EXITING AND OCCUPANCY PLAN <br /> 1/4" = V-0" <br /> N <br /> SHEET <br /> 0 <br /> NN 1 2 4 8 <br /> CD <br /> N <br /> Q0 SCALE: 1/4"= V-0" PROJECT <br /> NORTH n5 <br />