FLOOR PLAN SYMBOLS DIMENSION PLAN NOTES FLOOR PLAN GENERAL NOTES
<br /> WALL FRAMING, SEE PARTITION ALL EXTERIOR DIMENSIONS TO EDGE OF FOR DIMENSIONS SEE (2 /A2.0) PROVIDE FIRE BLOCKING AND DRAFT STOPPING AT 2"AIR SPACE BETWEEN COOLER WALL AND
<br /> SCHEDULE FOUNDATION, FACE OF STUD, AND FACE OF ALL UNSPRINKLERED COMBUSTIBLE CONSTRUCTION BUILDING WALL, OR ANY EQUIPMENT ADJACENT TO
<br /> STOREFRONT, U.O.N. WALL HEIGHTS TYPICAL FULL HEIGHT TO BOTTOM OF IN STUD WALLS, CONCEALED SPACES, FURRED COOLER. WALK-IN COOLER SUPPLIED BY 7-ELEVEN,
<br /> 1 HR. RATED WALL CONSTRUCTION PER ALL INTERIOR DIMENSION TO FACE OF STUD, U.O.N. FLOOR OR ROOF FRAMING EXCEPT WHERE AREAS (10'-0" MAX. HORIZONTAL AND VERTICAL INC, INSTALLATION TO BE DETERMINED BY
<br /> CBC TABLE 721.1 (2)- ITEM #13-1.1 INDICATED ON STRUCTURAL DRAWINGS OR WHERE INTERVALS)AT FLOOR/CEILING AND ROOF/CEILING CONSTRUCTION PROJECT MANAGER.
<br /> • CONTRACTOR TO COORDINATE ALL DIMENSIONS AND INDICATED AS FIRE RATED OR SOUND AND OTHER LOCATIONS PER CBC 718.2
<br /> STRUCTURAL ELEMENTS LAYOUTS WITH INTERIOR CONSTRUCTION (U.O.N.) CONTRACTOR TO PROVIDE AND INSTALL WALL
<br /> STRUCTURAL COLUMNS, S.S.D. DRAWINGS PRIOR TO ANY CONSTRUCTION. PROVIDE VENTILATION AT ALL EXTERIOR COLUMNS, BACKING FOR WALL HUNG FIXTURES AND TOILET
<br /> • ALL ANGLED WALLS (OTHER THAN 90 DEG.) SHALL BE SOFFITS AND WALLS (IF UNINSULATED). PROVIDE ACCESSORIES.
<br /> 45 DEGREES (U.O.N.) 6 SQ. IN / 100SF MIN.
<br /> • ALL WOOD IN CONTACT WITH CONCRETE MUST BE
<br /> 1 W 6 A EXTERIOR WALL TYPES, ALL EXTERIOR WALLS SHALL BE CONSTRUCTED OF PROVIDE SMOOTH, DURABLE, EASILY CLEANABLE, PRESSURE TREATED, MOISTURE RESISTANT WOOD.
<br /> SEE WALL TYPE DRAWINGS ON SHEET A6.2 2 X 6 STUDS @ 16" O.C. (U.O.N.)- S.S.D. LIGHT-COLORED, AND NON-ABSORBANT WALL AND
<br /> CEILING FINISHES AT: WHERE FOOD IS PREPARED MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT 5865 Owens Drive
<br /> • TYP. INTERIOR WALL FULL HEIGHT TO UNDERSIDE OF OR PACKAGED, FOOD OR BEVERAGE IS DISPENSED, EXCEED: 5.0 L.B.F. FOR INTERIOR DOORS. Pleasanton, CA 94588
<br /> A INTERIOR WALL TYPE, aoo KEYNOTE LEGEND ROOF SHEATING. WHERE UTENSILS ARE WASHED OR STORED, 925-251-7200
<br /> SEE PARTITION SCHEDULE ON SHEET A6.2 JANITORIAL AREAS, RESTROOMS, WALK-IN ALL DOORS SHALL BE KEYLESS IN DIRECTION OF
<br /> • ALL SHEATHING SURFACE PLANES TO BE REFRIGERATORS/FREEZERS, AND GARBAGE AND EGRESS.
<br /> E1 PRE-FABRICATED COOLER WALLS, CEILING, FLOOR, CONTINUOUS. ALL GYPSUM BOARD PARTITIONS REFUSE STORAGE.
<br /> OWINDOW TYPE - SEE SCHEDULE ON DOORS AND RACKS. MAINTAIN 2"AIR SPACE BETWEEN SHALL BE TAPED AND SANDED SMOOTH WITH NO FIRE EXTINGUISHER: #10 CLASS ABC WITH UL RATING
<br /> '4 SHEET A6.0VISIBLE JOINTS. COORDINATE WITH INTERIORS CONTRACTORS SHALL NOT SCALE THESE 4A-60BC. SURFACE MOUNTED ON WALL WITH
<br /> 1i COOLER AND ADJACENT WALLS PER MANUFACTURES DRAWINGS. DRAWINGS. IN THE EVENT OF OMISSION OF MANUFACTURERS ALL STEEL WALL BRACKET. JL
<br /> SPECIFICATIONS. CONTRACTOR TO FIELD VERIFY NECESSARY DIMENSIONS THE CONTRACTORS SHALL INDUSTRIES INC. COSMIC 10E OR APPROVED EQUAL
<br /> DOOR TYPE - SEE SCHEDULE ON DIMENSIONS WITH PROJECT MANAGER. ( )
<br /> PROTECT FROM FREEZING, INSULATE AND WRAP ALL NOTIFY THE CONSTRUCTION PROJECT MANAGER. WITH INSPECTION TAG AS REQUIRED BY LOCAL
<br /> lol SHEET A6.0
<br /> PLUMBING AND FIRE SPRINKLER PIPES, FITTINGS CODES.
<br /> AND OTHER ITEMS EXPOSED TO AN EXTERIOR WALL/ GENERAL CONTRACTOR SHALL VERIFY ALL BUILDING
<br /> ROOM NUMBER SOFFIT OR ROOF SURFACE. DIMENSIONS, AND SITE GRADES PRIOR TO START OF CONTRACTOR TO INSTALL COAT HOOKS FOR
<br /> WORK. EMPLOYEES. REFERENCE SHEET EF1 ITEM 220.
<br /> • ALL EXTERIOR WALLS SHALL BE FULLY INSULATED, INSTALL 3 IN OFFICE. LOCATION TO BE DETERMINED
<br /> HOSE BIB - S.P.D. FULL HEIGHT TO UNDERSIDE OF ROOF SHEATHING. VERIFY SIZE, LOCATION, AND CHARACTERISTICS, OF BY CONSTRUCTION PROJECT MANAGER. SEE DOOR
<br /> HB ALL WORK AND EQUIPMENT TO BE FURNISHED BY HARDWARE SCHEDULES.
<br /> • ALL INTERIOR WALLS SHALL BE FULLY INSULATED OWNER OR OTHERS, WITH THE MANUFACTURER OR
<br /> WITH SOUND BATTS, FULL HEIGHT. SUPPLIER BEFORE ANY CONSTRUCTION PERTAINING APPLY 3M SUN CONTROL WINDOW FILMS @ ALL CONSULTANT
<br /> COOLER WALL TO SAME IS BEGUN. SOUTH, EAST, AND WEST FACING GLASS (3M-1).
<br /> • ALL ROOFS SHALL BE FULLY INSULATED TO NOTE NO FILM SHOULD BE APPLIED TO THE
<br /> UNDERSIDE OF SHEATHING TO PERIMETER OF ALL EXTERIOR WALL DIMENSIONS ON THE PLANS STOREFRONT DOORS. (REFERENCE SHEET A6.1 FOR
<br /> BUIDING ENVELOPE. UNLESS OTHERWISE NOTED ARE TO OUTSIDE FACE MATERIALS SCHEDULE).
<br /> 1 OF SIP, CMU BLOCK OR STRUCTURAL SHEATHING.
<br /> 2 2.5 PROVIDE BACKING IN ALL WALLS AS REQUIRED FOR G.C. TO FURNISH AND INSTALL RIS BACKBOARD AT
<br /> SHELVES, CABINETS, BRACKETS, GRAB BARS, ISP DESK. REFERENCE MATERIALS SCHEDULE ON sip
<br /> HANDRAILS, ETC. SHEET A6.1.
<br /> 6" 43'-4" 1'-0"
<br /> 6" 8'-6" 17'-10" 4'-0" 9'-0" O6N
<br /> 4'-0" ELEvEn
<br /> WA3.1
<br /> 4'-2.. 2'-6" 1
<br /> F A4.0
<br /> 44'-4' I 2
<br /> � I OW6J I OW6H OW6J OW6H
<br /> A `� `� I ' `� A A 107A q 7-11 #1043581
<br /> DR N
<br /> 22 A
<br /> ELEC. co R O W 6 N ELEC.
<br /> 107 o 5'-3" 3 107 A I 1
<br /> A4.2 A A4.1
<br /> BACKROOM A
<br /> A
<br /> 3D 104 A i BACKROOM
<br /> OW6L
<br /> WOMEN'S ~
<br /> W
<br /> WOMEN'S N Flu N ZD
<br /> O W 6 M e 105 106A 103A z W
<br /> %OFFICE
<br /> = -- MEN'S N _ MEN'S ® A.6 0 W 6 G /'1
<br /> N " 106 OFFICE o 105A 106 103 2 Z Q
<br /> 103 - - -- V
<br /> 5'-6" z cl i A A4.1 CQ
<br /> 9 5/8" A O W 6 P G z
<br /> A _ W O
<br /> > <
<br /> o �
<br /> N 11" A I Q U
<br /> (0 O
<br /> 6"MIN. I N
<br /> M T-11 5/8" 4'-83/8" 8'-81/2" T-10" 10'-91/2" 6'-4" I z (f)
<br /> FRI C45 O
<br /> O W 6 F SALESI J
<br /> SALES
<br /> 102 102 I 3 —
<br /> A4.1
<br /> I I O I z
<br /> N I
<br /> I
<br /> 2 ----- --------------------------------- -------------------------- -- - I ----�
<br /> A4.0
<br /> I 101A I
<br /> I I
<br /> I I I
<br /> A3.1 1 I I 1 A3.0
<br /> ' I
<br /> M I PR#2 01 .06.2020
<br /> � I I
<br /> x
<br /> MERCHANDISE I REVISIONS
<br /> C
<br /> MERCHANDISE
<br /> 101 _ I 1 PR#1 12.23.19
<br /> zo iOW6G
<br /> OW6P
<br /> C
<br /> I ,
<br /> I '
<br /> I
<br /> E I MEMEao -—-—- 1
<br /> A4.2
<br /> _N I OW6J
<br /> FREEZER
<br /> FREEZER 108
<br /> °° 108
<br /> o o D I O W 6 H
<br /> co
<br /> ICE o o < E
<br /> 109 E
<br /> Q
<br /> ICE OW6J
<br /> C%
<br /> Lu
<br /> � J
<br /> >
<br /> 0
<br /> COOLER o w 6 F
<br /> COOLER VAULT� s
<br /> w
<br /> [r4,-31/2,,
<br /> coVAULT O W 6 F
<br /> VAULT DIM 110 E. � E1
<br /> 41'-101/2" D I D
<br /> VAULT DIM2"MIN D SEAL/SIGNATURE
<br /> CLR OW6Q
<br /> N U OW6Q I JOB NO. 1497.009
<br /> D —
<br /> OD 2 DRAWN JK
<br /> EQ EQ 11 1L.EQ � EQ
<br /> CHECK GM
<br /> ct A3.0 2
<br /> 6" 3'-6" 9'-0" 4'-0" 10'4" 4'-0" 9'-0" T-6" 6" O w 6 Q O W 6 F O W 6 Q F O W 6 Q O W 6 F A4.2 O W 6 Q FLOOR PLAN A N D
<br /> DIMENSION PLAN
<br /> (:
<br /> yll
<br /> IMENSION FLOOR PLAN GROUND FLOOR PLAN SHEET
<br /> N
<br /> 0
<br /> /4" = 1'-0" 1/4" = 1'-0"
<br /> No 1 2 4 8
<br /> SCALE: 1/4"= V-0" PROJECT A200
<br /> NORTH