Laserfiche WebLink
1 M 2 A PARTITION TAG <br /> PARTITION SERIES <br /> 2X4 PT DF FLAT STUD FURRING STRIPS (SEE TABLE C - BELOW) <br /> FRAMING MEMBER DEPTH 1 <br /> (SEE TABLE B - BELOW) <br /> FRAMING MATERIAL <br /> (SEE TABLE A - BELOW) <br /> SHEATHING <br /> FIRE RATING (IF APPLICABLE) <br /> WOOD STUD ;>< <br /> i ;>< >< WOOD STUD TABLE A- FRAMING MATERIAL SCHEDULE <br /> 5865 Owens Drive <br /> WEATHER BARRIER owl Pleasanton, CA 94588 <br /> LABEL MATERIAL TYPE <br /> LAP SIDING,SEE FINISH SCHEDULE 5/8"TYPE'X'GYP.BOARD 925-251-7200 <br /> I W WOOD <br /> INSULATION BLANKET N METAL C-STUD <br /> I <br /> C CMU <br /> I <br /> TABLE B- FRAMING DEPTH SCHEDULE <br /> TAG NUMBER MTL STUD MTL C-H WOOD STUD CMU <br /> DESIGNATION DEPTH STUD DEPTH DEPTH WIDTH <br /> SCALE: 3"=1'-0" SCALE: 3"=V-0" - NO FRAMING <br /> 0 7/8" FURRING CHANNEL N/A N/A <br /> Q SERIES PARTITION 10 P SERIES PARTITION 5 1 1 5/8" N/A 3/4" N/A <br /> 2 2 1/2" 2 1/2" 1 1/2" N/A CONSULTANT <br /> 3 3 5/8" N/A 2 1/2" N/A <br /> 4 4" 4" 3 1/2" 3 5/8" <br /> II 6 6" 6" 5 1/2" 5 5/8" <br /> I <br /> 8 8" N/A 7 1/4" 7 5/8" <br /> I <br /> 10 10" N/A 9 1/4" 9 5/8" <br /> I <br /> 12 12" N/A 11 1/4" 11 5/8" <br /> II <br /> I <br /> I <br /> ELEvEn <br /> 7771 STEEL SHEET THICKNESS FOR STUDS AND RUNNERS <br /> IF <br /> W D <br /> 00DSTUD WOOD STUD <br /> ROOF DECK ROOF DECK I I GAGE* MIN. STEEL BASE METAL THICKNESS UNCOATED <br /> SHEATHING PLYWOOD SHEATHING INCH MILS MM <br /> I I <br /> INSULATION BLANKET I i INSULATION BLANKET 12 0.1017 97 X <br /> WEATHER BARRIER WEATHER BARRIERS 14 0.0713 68 X 7-11 #1043581 <br /> 16 0.0566 54 1 .34 <br /> I <br /> CEMENT PLASTER CEMENT PLASTER i 18 0.0451 43 1 .09 <br /> 1, 20 0.0312 30 0.84 <br /> I 5/8"TYPE'X' I <br /> 22 0.0270 27 0.68 <br /> SIM I GYPSUM BOARD <br /> II 25 0.0179 18 0.45 <br /> *GAGE 16,18 USED FOR STRUCTURAL FRAMING; 20, 22, <br /> I <br /> AND 2 EDFOR NON-STRUCTURAL <br /> 5 US OFRAMING <br /> I <br /> *USE OF DIMPLED STEEL STUDS ACCEPTABLE PROVIDED Wz <br /> SCALE: 3"-1'-0" SCALE: 3°-1'-0° CONTRACTOR SUPPLIES DOCUMENTATION PROVING THE LLI <br /> EQUIVALENT MINIMUM BASE METAL THICKNESS IS <br /> N SERIES PARTITION 9 M SERIES PARTITION 4 ACHIEVED O1— <br /> GENERAL NOTESU) <br /> Z <br /> 1 . PARTITION TYPES ARE NOT SEQUENTIAL. J Q V <br /> EXISTING ----- 2. ALL PARTITION SHEATHING TO BE 5/8 TYPE X GYPSUM <br /> PREFABRICATED COOLER STRUCTURE/ I BOARD UNLESS OTHERWISE NOTED. Z <br /> WALL PARTITION/ I = 3. ALL PARTITIONS SHALL BE COORDINATED WITH Lu <br /> STOREFRONT I EXTERIOR SCHEDULED FINISHES FOR PARTITION LAYOUT AND 06 O <br /> SUBSTRATE PER PLAN SUBSTRATE I OR 2X4 PT DF FLAT STUD FURRING STRIPS REQUIRED CLEARANCES. <br /> PER PLAN I TENANT 4. PROVIDE BACKING IN PARTITIONS FOR ARTWORK Q U <br /> COOLER/ I WALL 518'TYPE'X GYP.BOARD HANGING AS INDICATED. SEE CONSTRUCTION PLAN(S) <br /> FREEZER <br /> COOLER/ <br /> i <br /> FREEZER INSULATION BLANKET A ` V <br /> 5/8"TYPE'X'GYP.BOARD 5. FOR INTERIOR FRAMING LIMITING HEIGHTS REFER TO Z U) <br /> I <br /> PLYWOOD SHEATHING <br /> I O <br /> PLYWOOD SHEATHING = SSMA TABLES FOR INTERIOR NON-STRUCTURAL NON- 4� <br /> (� <br /> 2„ WOOD STUD COMPOSITE PARTITIONS J <br /> W000sTUD 6. CONTRACTOR TO RE-CONFIRM STUD SIZING AND SUBMIT O — <br /> TOPOFCONC WEATHER BARRIER- GP DENSGALSS GOLD TYPE X OR EQUAL SELECTION CRITERIA FOR REVIEW INCLUDING � <br /> TOP OF CONC <br /> LAP SIDING,SEE FINISH SCHEDULE - WEATHER BARRIER DELINEATION OF SLAB TO UNDERSIDE OF STRUCTURE Z <br /> INFORMATION <br /> INSULATION BLANKET LAP SIDING,SEE FINISH SCHEDULE 7. PARTITION LIMITING HEIGHT HAS BEEN DETERMINED BY A <br /> SINGLE MANUFACTURER'SPROPRIETARY STRUCTURAL <br /> OE <br /> O <br /> 2X4 PT DF FLAT STUD FURRING STRIP <br /> S <br /> COOLER/ FREEZER WALL <br /> TABLESCONTRACTOR HALL VERIFY ENGINEERED ERED <br /> L <br /> AD <br /> COOLER/ FREEZER WALL AGAINST WALL CAPACITY F METAL STUDS CONFORMING TO THE <br /> NOTE: REFERENCE A2.2 FOR NOTE: REFERENCE A2.2 FOR REQUIREMENTS OF THE SPECIFICATIONS AND INCLUDE <br /> WALL FINISH AND SUBSTRATE WALL FINISH AND SUBSTRATE V. PARTITION LIMITING HEIGHT IN METAL STUD SUBMITTAL. <br /> TYPES. TYPES. AN8. IDENTIFY THE TYPE OF FIRE WALL, FIRE BARRIER, FIRE <br /> PARTITION, SMOKE BARRIER AND SMOKE PARTITION IN <br /> SCALE: 1"=1'-0" SCALE: 1"=V-0" SCALE: 3"=1'-0" SCALE: 3"=V-0° AN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR <br /> ATTIC SPACE. THE MARKING SHALL BE LOCATED WITHIN <br /> E SERIES PARTITION 18 D SERIES PARTITION 13 L SERIES PARTITION 8 H SERIES PARTITION 3 15-FEET OF EACH END, AT INTERVALS NOT EXCEEDING <br /> 30-FEET MEASURED HORIZONTALLY ALONG THE WALL OR PR#2 01 .06.2020 <br /> PARTITION, AND BE NOT LESS THAN 3-INCHES IN HEIGHT. <br /> THE WORDING SHALL STATE: "FIRE AND/OR SMOKE <br /> BARRIER-PROTECT ALL OPENINGS". SEE CBC 703.7 <br /> 9. WALL ASSEMBLIES SHALL MEET A COMPOSITE STC <br /> RATING OF AT LEAST 50 OR A COMPOSITE OITC RATING REVISIONS <br /> OF NO LESS THAN 40. <br /> 1 <br /> INSULATION BLANKET <br /> ROOF DECK ROOF DECK <br /> Tj <br /> il <br /> PLYWOOD SHEATHING <br /> ROOF DECK <br /> WOOD STUD <br /> WEATHER BARRIER <br /> 'j <br /> 3.4 GALV.METAL LATH <br /> SCRATCH COAT <br /> MORTAR <br /> THIN BRICK <br /> B.O. CEILING <br /> SCHEDULED CEILING <br /> B.O. CEILING -- <br /> 1I <br /> SCHEDULED CEILING 5/8"TYPE 'X' <br /> GYPSUM BOARD <br /> METAL TOP TRACK SCHEDULED CEILING <br /> METAL TOP TRACK <br /> METAL STUD SCALE: 3"=1'-0" <br /> METAL STUD FRAMING <br /> FRAMING METAL STUD FRAMING PER WALL TAG G SERIES PARTITION 2 <br /> PER WALL TAG <br /> PER WALL TAG BELOW BELOW <br /> BELOW <br /> SUBSTRATE PER PLAN SUBSTRATE PER PLAN <br /> EXTERIOR <br /> OR — SUBSTRATE PER PLAN MTL STUD FRAMING <br /> MTL STUD FRAMING EXTERIOR <br /> TENANT O <br /> WALL OR MTL STUD FRAMING SOUND BATT INSULATION @ <br /> SOUND BATT TENANT RESTROOM ONLY <br /> INSULATION WALL <br /> @ RESTROOM ONLY SOUND BATT <br /> INSULATION 5/8"TYPE'X' <br /> @ RESTROOM ONLY GYPSUM BOARD <br /> i <br /> I I <br /> — METAL STUD TRACK WOOD STUD WOOD STUD SEAL/SIGNATURE <br /> METAL STUD TRACK ATTACHED W/ <br /> ATTACHED W/ METAL STUD TRACK FASTENERS @ 24" O.C. MAX. PLYWOOD SHEATHING I PLYWOOD SHEATHING ' I JOB NO. 1497.009 <br /> FASTE ERS @ 24" O.C. MAX. ATTACHED W/ TOP OF CONC 'I <br /> O6„ TOP OF CONC FASTENERS @ 24" O.C. MAX. INSULATION BLANKET I INSULATION BLANKET i DRAWN JK <br /> 1 1 TOP OF CONC <br /> WEATHER BARRIER - WEATHER BARRIER- CHECK GM <br /> CEMENT PLASTER CEMENT PLASTER - <br /> 3-5/8" MTL. STUDS WALL PARTITION <br /> SCHEDULE <br /> CO 3-5/8" MTL. STUDS BO 3-5/8" MTL. STUDS A.6 6" MTL. STUDS <br /> N NOTE: REFERENCE A2.2 FOR NOTE: REFERENCE A2.2 FOR NOTE: REFERENCE A2.2 FOR I' <br /> N WALL FINISH AND SUBSTRATE WALL FINISH AND SUBSTRATE WALL FINISH AND SUBSTRATE <br /> O TYPES. TYPES. TYPES. <br /> N <br /> SHEET <br /> N SCALE: 1"=1'-0" SCALE: 1"=1'-0" SCALE: 1"=V-0" SCALE: 3"=1'-0" SCALE: 3"=V-0" <br /> O <br /> NA 02 <br /> C SERIES PARTITION 21 B SERIES PARTITION 16 A SERIES PARTITION 11 J SERIES PARTITION 6 F SERIES PARTITION 1 <br />