My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1515
>
1600 - Food Program
>
PR0546273
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/18/2021 8:53:41 AM
Creation date
2/17/2021 4:21:04 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546273
PE
1615
FACILITY_ID
FA0026203
FACILITY_NAME
7 ELEVEN 38877A
STREET_NUMBER
1515
Direction
E
STREET_NAME
MAIN
STREET_TYPE
ST
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1515 E MAIN ST
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
257
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i ► <br /> 2 ROOFTOP UNIT SCHEDULE AIR DEVICE SCHEDULE <br /> HVAC NOTES 5865 Owens Drive <br /> Pleasanton, CA 94588 <br /> COOLING CAPACITY HEATING CAPACITY FRAME 925-251-7200 <br /> SUPPLY FAN @ 95°F (MBH) @ 30°F ELECTRICAL DATA MARK SERVICE MANUFACTURER MODEL STYLE FACE SIZE NECK SIZE TYPE NOTES 1. NOTES APPLY TO ALL MECHANICAL SHEETS. <br /> NOMINAL E.S.P. OSA GAS INPUT EAT/LAT NOT USED 2. EACH CONTRACTOR IS RESPONSIBLE FOR HAVING <br /> MARK MANUFACTURER MODEL TONS CFM (IN. WC) (CFM) TOTAL SENSIBLE SEER\EER (MBH) (°F) V/PH MCA MOCP WEIGHT THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br /> CD2 SUPPLY METAL*AIRE 5700-6 AL ROUND NECK CEILING DIFFUSER 24 X 24 PER PLAN LAY-IN A, B, C, D SPECIFICATIONS AS THEY RELATE TO THIS WORK. NO <br /> RTU-1 CARRIER 48HC-D08 7.5 3000 0.6" 250 86.2 74.4 12 90/125 1 66.7/98.4 208/3 41 50 1173 CD3 SUPPLY METAL*AIRE 5700-1 AL ROUND NECK CEILING DIFFUSER 12 X 12 PER PLAN SURFACE A, B, C, D ADDITIONAL COMPENSATION SHALL BE ALLOWED DUE TO <br /> RTU-2 CARRIER 48HC-D08 7.5 3000 0.6" 250 86.2 74.4 12 90/125 66.7/98.4 208/3 41 50 1173 CD4 SUPPLY METAL*AIRE V4004D-1 ALUMINUM DOUBLE DEFLECTION WALL 14 X 8 12 X 6 SURFACE A, B, C, D LACK OF THIS KNOWLEDGE. <br /> NOTES (ALL NEW UNITS): SUPPLY GRILLE 3. PROVIDE ALL MATERIALS FOR A COMPLETE <br /> A. PROVIDE FILTER WITH EACH UNIT. RG1 RETURN METAL*AIRE CC5-6 EGGCRATE CEILING RETURN GRILLE 24 X 24 22 X 22 LAY-IN A, B, C, D INSTALLATION IN ALL RESPECTS READY FOR INTENDED <br /> B. PROVIDE WITH FULLY MODULATING DRY-BULB TITLE-24 COMPLIANT ECONOMIZER. NOT USED USE AND IN STRICT ACCORDANCE WITH STATE AND LOCAL <br /> C. SMOKE DETECTORS TO BE PROVIDED AND INSTALLED BY CARRIER. LOCATE AS SHOWN ON PLAN. CODES AND MANUFACTURER'S RECOMMENDATIONS. <br /> D. CONDENSATE TRAP SHALL BE PROVIDED AND INSTALLED BY CONTRACTOR. PROVIDE TRAP OF ADEQUATE DEPTH TO PREVENT GENERAL INFORMATION (ALL DEVICES): <br /> STATIC FROM OVERCOMING TRAP SEAL. ROUTE TO NEAREST APPROVED RECEPTOR. 1.ALL DIFFUSERS ARE 4-WAY THROW UNLESS NOTED OTHERWISE. 4. SPRINKLER HEAD AND LIGHTING FIXTURE LOCATIONS <br /> E. PROVIDE WITH STANDARD ROOF CURB AND ACCESSORIES. 2.ALL AIR DEVICES SHALL BE PROVIDED BY 7-ELEVEN AND INSTALLED BY THE CONTRACTOR. FOR TAKE PRECEDENCE OVER DIFFUSER LOCATIONS. <br /> F. OUTDOOR AMBIENT DESIGN TEMPERATURE 95 DEG.F. ADDITIONAL INFORMATION CONTACT CHAD LITERSKY(214) 350-6871 EXT. 2140 WITH BARTOS INDUSTRIES. COORDINATE WITH ELECTRICAL CONTRACTOR AND FIRE <br /> G. SET FAN OPERATION TO CONTINUOUS. PROTECTION CONTRACTOR. <br /> H. TEMPERATURE SET POINTS DURING OCCUPIED HOURS- HEATING MODE: 66°F-COOLING MODE: 75°F. NOTES: CONSULTANT <br /> I. PROVIDED BY 7-ELEVEN AND INSTALLED BY CONTRACTOR, FOR ADDITIONAL INFORMATION CONTACT NATIONAL ACCOUNT A. DIFFUSER NECK SIZE SHALL BE SAME AS BRANCH DUCT SIZE UNLESS NOTED OTHERWISE. 5. DUCTWORK IDENTIFICATION AND INSTALLATION TO <br /> REPRESENTATIVE BOBBY KIMBRELL(512)267-3366, BOBBY.KIMBRELL@CARRIER.UTC.COM. B. DAMPER AT TAKEOFF TO DEVICE. ADHERE TO GOVERNING CODES. <br /> J. CONTACT AUTOMATED LOGIC (ALC)AT(866)390-4275 FOR BUILDING ENERGY MANAGEMENT SYSTEM. C. STANDARD OFF-WHITE FINISH. <br /> K. PROVIDE WITH I/O FLEX CONTROL MODULE. D. PROVIDE NECK FOR DUCT CONNECTION. 6. DUCT SIZES INDICATED ARE INSIDE CLEAR DIMENSIONS <br /> L. PROVIDE WITH CONDENSER COIL HAIL GUARD (LOUVERED DESIGN). AND REPRESENTATIVE OF THE INSIDE EQUIVALENT FREE <br /> M. PROVIDE WITH PRE-COATED OUTDOOR COILS WITHIN A 5 MILE RADIUS OF ANY SALT OR BRACKISH WATER. AREA REQUIRED TO MAINTAIN THE AIR FLOW SPECIFIED. <br /> LOUVER SCHEDULE IF DUCT LINING IS REQUIRED, INCREASE DUCT SIZE TO <br /> MAINTAIN ORIGINAL INSIDE DIMENSIONS. IF DUCT SIZES <br /> EXHAUST FAN SCHEDULE MARK QUANTITY MANUFACTURER MODEL SIZE FREE AREA CFM E.S.P. (IN. WC) VELOCITY (FPM) NEED TO BE ALTERED FOR SPACE REQUIREMENTS, <br /> LV-1 2 GREENHECK ESJ-401 48"X 28" 4.32 SQ. FT. 3000 0.08" 679 ENSURE THE ORIGINAL INSIDE DUCT EQUIVALENT FREE <br /> MARK QUANTITY MANUFACTURER MODEL CFM E.S.P. (IN. WC) V/Ph WATTS CONTROL AREA IS MAINTAINED. ELEVEnNOTES: 2 <br /> EF-1 2 GREENHECK SP-6150 100 0.25" 120/1 129 LIGHT SWITCH A. PROVIDE WITH SLEEVE AND BR-30 BAROMETRIC RELIEF DAMPER. 7. TYPICAL BRANCH DUCT FITTING DETAIL IS APPLICABLE <br /> B. LOUVER SHALL BE PRE-FINISHED DARK BRONZE (KYNAR 70% 3-COAT-CFT5835-C) IN COLOR. THROUGHOUT. FLEXIBLE DUCTWORK IS ONLY PERMITTED <br /> NOTES: C. TO BE PROVIDED BY 7-ELEVEN AND INSTALLED BY CONTRACTOR. FOR ADDITIONAL FOR FINAL CONNECTION -MAX LENGTH OF 6'-0". <br /> A. PROVIDE GRAVITY BACKDRAFT DAMPER. INFORMATION CONTACT CHAD LITERKSY(214) 350-6871 EXT. 2140 WITH BARTOS INDUSTRIES. <br /> B. PROVIDE SPRING VIBRATION ISOLATORS FOR HANGER ROD SUPPORTS. 8. FURNISH AND INSTALL VOLUME/BALANCE DAMPERS AT <br /> C. TO BE PROVIDED BY 7-ELEVEN AND INSTALLED BY CONTRACTOR. FOR ADDITIONAL ALL BRANCH DUCTS TO DIFFUSERS. LOCATE DAMPERS A <br /> INFORMATION CONTACT CHAD LITERKSY(214)350-6871 EXT. 2140 WITH BARTOS INDUSTRIES. MINIMUM 4'-0"AWAY FROM DIFFUSERS. PROVIDE ACCESS <br /> AS REQUIRED. <br /> 9. ALL CEILING DIFFUSERS ARE 4-WAY PATTERN UNLESS <br /> SHOWN OTHERWISE. <br /> OSA CALCULATIONS <br /> 10. PROVIDE A COMPLETE TEST AND BALANCE FOR HVAC <br /> CLASSIFICATION AREA CFM PER PEOPLE CFM PER ZONE SYSTEM.AIR BALANCE SHALL BE WITHIN 5% OF <br /> FT2 AREA FT2 PERSONS PERSON EFFECTIVENESS SCHEDULED AIRFLOWS. PROVIDE A COPY TO THE OWNER <br /> (AZ) (Ra) (PZ) (Rp) (EZ) AND ENGINEER. <br /> 11. INSTALL VTR'S AND EXHAUST FANS A MINIMUM OF 10 FT <br /> SUPERMARKET 2760 0.06 24 7.5 0.8 FROM OUTSIDE AIR INTAKE. <br /> V= RP+RA V=V/E 12. DO NOT LOCATE SUPPLY GRILLES DIRECTLY OVER OPEN <br /> bz p z a z oz 3z z TOTAL REQUIRED: 432 AIR CASES. PROVIDE BAFFLES ON DIFFUSERS WITHIN 10'-0" <br /> 7.5*24+0.06*2760 = 346 346/0.8 =432 TOTAL SUPPLIED: 500 TO DIRECT AIRFLOW AWAY FROM OPEN AIR CASES. w <br /> Lu <br /> MECHANICAL SYMBOLS O 1- <br /> AIR BALANCE SCHEDULE � ) W <br /> MARK OUTSIDE EXHAUST LV1 LV1 18/12 RECTANGULAR DUCT 18"WIDE V J z_ Q <br /> BY 12" DEEP (INSIDE CLEAR DIMENSIONS) <br /> AIR CFM AIR CFM 3000 CFM 3000 CFM 2 _ Q C.) <br /> RTU-1 250 9'-10"AFF TO 9'-10"AFF TO <br /> RTU-2 250 ❑ BOTTOM OF LOUVER BOTTOM OF LOUVER 12„ (IN DIAMETER ROUND DUCT) z <br /> INSIDE CLEAR DIMENSIONS w O <br /> EF-1 200 � O� <br /> TOTAL 500 200 SUPPLY DUCT IN SECTION z <br /> -� N RG1 WITH INCA MOD L 00 Q O <br /> J J x1 7 x <br /> BID 00 DAMPER, TYP. O 4 EF-1 RETURN OR EXHAUST DUCT IN SECTION <br /> ED <br /> MI <br /> I'D <br /> MI <br /> `� 100 CFM z U) <br /> ELBOW WITH TURNING VANES 06 O <br /> 20 x16 20 x16 20 x16 20 x16 <br /> 0 -. N\ U) <br /> F CD3 <br /> CD2 CD2 _ 50 CFM CD4 O J <br /> 6"0 100 CFM � TEE WITH TURNING VANES � <br /> 375 CFM 10"ra 10"o 375 CF A 11'-6"AFF <br /> 12"0 12"0 - <br /> CD2 TE 8" E-,(FfAtIST_ El <br /> 6 o CFM DUC UP THROUGH <br /> ROUND (OR OVAL) ELBOW <br /> 12'10 ROOF WITH ROOF <br /> SUPPLY AIR DIFFUSER WITH <br /> CRIfEN ROUND SUPPLY DUCT <br /> 6"o <br /> RETURN OR EXHAUST AIR DIFFUSER <br /> X WITH ROUND DUCT <br /> 6"o <br /> CD DIFFUSER OR GRILLE TYPE&CFM <br /> VERTICAL 1/4"X 2" SAMMY 50 CFM 400 CFM <br /> 3/8"ALL THREAD ANCHOR, �0 6„0 <br /> TYP OF 2 <br /> 12"o-,,, OT THERMOSTAT <br /> CD2 CD2 <br /> SIPS ROOF 3 5 CFM 10"o 10"o 375 CF i <br /> 12"0 12"0 D2 8"x8" O SPACE TEMP. SENSOR BLDG DEPT. 10.11 .19 <br /> 60 CFM <br /> 12"0 S H C SPACE TEMP./HUMIDITY/CO2 COMBO SENSOR <br /> (3-WAY) F Gi 10 CF <br /> 16"0 117 M <br /> 13' <br /> OD SMOKE DETECTOR <br /> _ REVISIONS <br /> 0 16"0 OR SMOKE DETECTOR TEST/RESET STATION <br /> 3/8" HEX N 10"� 1 PR#1 12.20.19 <br /> NUT, TYPBALANCE DAMPER 2 PR#2 01.06.20 <br /> CUSH-A-CLAMP 3/8"ALL S A-, RG1 <br /> FIRMLY CLAMPED THREAD ROD x 400 CFM <br /> TO PIPE, TYP 12"o M 10110 <br /> 3/8" HEX <br /> NUT, TYP <br /> �D2 <br /> CD2 CD2 D <br /> 12" <br /> 375 CFM 10"o 375 CFM 12"01 5/8"x 1 5/8" 12"0 10,,0 12"0 (3-WAY) <br /> 3/8"CHANNEL NUT GALVANIZED UNISTRUT <br /> WITH SPRING <br /> 2 24"x 8" <br /> PIPING INSULATION JJ 1.0 <br /> AS PER SPECS. ❑ 24"x18" J <br /> J 16"x12" COMMISSIONING AND T&B REQUIRED AND A REPORT <br /> REFRIGERANT LINE SUPPORT GENERATED USING 7-ELEVEN'S COMMISSIONING REPORT <br /> 3 N.T.S. D � TEMPLATE. PROVIDE A COPY TO THE OWNER AND ENGINEER. <br /> IF HVAC SYSTEM AIRFLOW CANNOT BE BALANCED PER PLANS, <br /> 26"x20" 10"o CONTACT ENGINEER OF RECORD FOR RESOLUTION. <br /> 12"0 <br /> ❑ 18"o 7 RG CD2 <br /> 1375 FM 10"0 6,� 00 CFM REF EMS1.0 SHEET FOR ADDITIONAL INFORMATION REGARDING <br /> L REF. PLANS FOR SPIN-IN FITTINGS <br /> rnq <br /> RUNOUT SIZES W/SCOOPS ARE TYP F 2 CD2 CD2 18"010 0 THE BUILDING ENERGY MANAGEMENT SYSTEM CONTROLS. <br /> NOT ACCEPTABLE 00 CFM o CONTACT AUTOMATED LOGIC(ALC)AT(866)390-4275 UPON <br /> 75 CF 75 CF 12"0 AWARD OF CONTRACT TO OBTAIN LIST OF CERTIFIED EMS <br /> 18"� RTU-2 12"0 12"0 3-WAY-61 AFF INSTALLERS. DURING CONSTRUCTION,AT 2 WEEKS PRIOR TO <br /> P P CD3 BUILDING TURNOVER, CONTACT ALC TO COORDINATE DELIVERY <br /> S H C R 100 CFM OF EMS PANEL. AFTER INSTALLATION OF EMS PANEL INCLUDING <br /> 6"0 CONNECTION OF CABLES, CONTACT ALC FOR START-UP OF EMS <br /> PANEL. START-UP TO BE DONE 2-3 DAYS PRIOR TO BUILDING <br /> TURNOVER. <br /> W <br /> FLEXIBLE DUCT FOR LAY-IN CEILING NOTE: SUPPLY AIR DEVICES SHALL BE <br /> FINAL CONNECTION ONLY: I INDICATED AS 3-WAY AIR DEVICES WHEN LOCATED WITHIN <br /> L=W/4, 4" MIN *45° LEAD IN 6-0" MAX LENGTH. - - - - - - - - - - - - - - - - - - A 10'-0" RADIUS OF THE OPEN AIR SANDWICH CASE <br /> BRANCH DUCT FITTING <br /> 2 N.T.S. 11/15/19 <br /> I <br /> SEAL/SIGNATURE <br /> D O O O O O O C O O O O O B O O O A JOB NO. 1497.009 <br /> DRAWN ZS <br /> CHECK CF <br /> MECHANICAL PLAN <br /> MECHANICAL PLAN <br /> SHEET <br /> 1 2 4 8 <br /> SCALE: 1/4"= 1'-0" PROJECT <br /> NORTH <br />
The URL can be used to link to this page
Your browser does not support the video tag.