Laserfiche WebLink
F - L <br /> Pastor Matt Linder !' <br /> May 5,2003 <br /> Page 5 <br /> k _ a , <br /> Table 2.,Summary of Nitrate Mass Balance'Analysis. <br /> F Scenario Result Acres Average Effluent Leachfeld Deep.Percolation <br /> (Nc) * (A) Daily Concen= Denitrifi- of Rainfall(R) <br /> Flow(Q) tration cation.(d) (Plate 1) <br /> (Table 1) (Nw) <br /> Standard Septic - . 5.4 mg/L-N 16.7 4369P 75 mg/L-.N 10% 5.01 in . <br /> System(Plate 2). r <br /> k OSI Treatment System 3.3 mg/L-N 16.7 436 gpd 38 mg/L-N 5% 5.01 in <br /> (5001.removal of Total <br /> Nitrogen)(Plate 3) ** <br /> ` OSI Treatment System 2.1 mg/L-N 16.7 436 gpd I9 mg/L-N 5% 5.01 in <br /> (75%removal of Total <br /> Nitrogen)(Plate 4) ** <br /> * Maximum contaminate level(MGL)for Nitrate in drinking water is 10 mg/L-N., <br /> ** Please note that 50%removal of nitrogen(75 mg/GN x 50%)is conservative,nitrogen removal may be up to <br /> 751/o+if conditions are optimal according to OSI. <br /> Discussion and Recommendations <br /> Because of the sandy coriditions,the rapid percolation rate measured,the shallow depth to <br /> r' ground water, and the pre-existing nitrate condition of the ground water, our previous report had <br /> recommended the use of an engineered septic system to reduce the nitrate concentration of the effluent in <br /> order to minimize the impact to the existing aquifer. Our office has evaluated several treatment systems <br /> and believes the.Orenco Advantex system is well suited for'the proposed facility. It'has a relatively low <br /> capital cost low maintenance cost reliable, and obtains performance consistency. <br /> Considering-that treatment_goals below 10 m for nitrate are e difficult o achieve and a <br /> grew ae endent on 'n uent concentrations of waste water,w �e believ that itis much more realistic to <br /> set treatment goals of 50%to 75%total nitrogen reduction of(Nw)over the long term. This is what <br /> Orenco Systems Inc. AdvanTex system has achieved. <br /> Based on the assumptions of the Hantzshe&Finnemore equation,we believe the proposed <br /> project will not cause a long term buildup of nitrates above 10 mg/L-N in the ground water regardless of <br /> the type of septic system. However, a short term build up is possible due to the rapid percolation rate , <br /> measured, the shallow depth to ground water. A water quality test of the aquifer indicates,it has been <br /> ` impacted by nitrates. The use of an OSI,AdvanTex treatment system will greatly.reduce these short term <br /> impacts and improve the long term water quality level(Nc)estimated by the Hantzshe&Finnemore <br /> equation. <br /> Our office believes the site is suitable for development unitizing an OSI Advantex waste water <br /> treatment system or an equivalently performing system.. Please refer to the soil suitability/nitrate loading <br /> 9SSOL1 <br /> r <br />