COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOFF
>
1515
>
2200 - Hazardous Waste Program
>
PR0538579
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2021 11:49:34 AM
Creation date
2/18/2021 11:37:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0538579
PE
2229
FACILITY_ID
FA0017929
FACILITY_NAME
SPEEDCO # 944
STREET_NUMBER
1515
STREET_NAME
HOFF
STREET_TYPE
DR
City
RIPON
Zip
95366
APN
24534026
CURRENT_STATUS
01
SITE_LOCATION
1515 HOFF DR
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
247
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of hazardous waste violations that have not been <br /> addressed for SPEEDCO #944 as of October 20, 2020. <br /> Open violations from August 28, 2020 inspection <br /> Violation#608-Failed to properly manage used oil and fuel filters. <br /> OBSERVATION: Containers of used metal oil filters out of compliance with the storage rules were observed on-site. <br /> A complete three-year bill of lading record for used oil filter recycling was not observed during the inspection. Bills <br /> of lading were not observed for the following date range: 8-28-2017 to 8-28-2020. <br /> The following were observed in the main maintenance shop: <br /> -One 15-gallon container with used metal oil filters observed with no lid and no drained used oil filters label. <br /> -One 15-gallon container with mixed paper and used metal oil filters observed with no lid and no drained used oil <br /> filters label. <br /> The following were observed in the hazardous waste storage area: <br /> -One 55-gallon container with used metal oil filters observed with no lid and no drained used oil filters label. <br /> -Two 55-gallon containers with mixed paper and used metal oil filters observed with no lid and no drained used oil <br /> filters label. <br /> REGULATION GUIDANCE: <br /> (b) "used oil filters"are defined as filters which contain a residue of used oil and which are exempt from regulation <br /> as a hazardous waste under the scrap metal provision found in federal law. <br /> (c)Used oil filters that meet the conditions of subsection (b)of this section and are managed and recycled in <br /> compliance with the following requirements shall not be regulated as hazardous waste. <br /> (1)The filters are drained of free-flowing used oil. For the purposes of this subsection,free-flowing is defined as a <br /> continuous stream of oil exiting the filter when the filter is inverted. Oil exiting drop by drop is not considered to be <br /> free-flowing. However, if the filter is equipped with a device(such as a rubber flap located just inside the filter <br /> opening)which impedes the drainage of used oil from the filter,that device shall be manipulated to allow the oil to <br /> exit the filter freely, or the filter punctured, crushed, opened, drained, or otherwise handled in a manner that will <br /> allow the used oil to exit the filter. <br /> (2)The drained used oil filters are transported for purposes of metal reclamation to any of the following: <br /> (A)A smelter or other scrap metal processor where they are recycled or; <br /> (B)A storage facility or consolidation facility that subsequently transfers the filters to a facility described in paragraph <br /> (A)or(C)of this subsection or; <br /> (C)A municipal solid waste incinerator for energy recovery, if the residual casings are subsequently transferred to a <br /> facility described in paragraph (A)of this subsection,or to a storage or consolidation facility that subsequently <br /> transfers the residual casings to a facility described in paragraph (A)of this subsection. <br /> (3)The drained used oil filters are accumulated, stored, and transferred in a closed, rainproof container that is <br /> capable of containing any used oil that may separate from the filters placed inside. Drums of used oil filters shall be <br /> sealed during transfer so that used oil will not spill out when they are laid upon their sides. Drums shall be secured <br /> as a load to prevent movement or tipping during transfer. Containers shall be labelled as"drained used oil filters" <br /> (not as hazardous waste)and show initial date of accumulation or receipt on each container of filters. <br /> (4)Storage of less than one ton of used oil filters shall be limited to one year. Storage of one ton or more of used oil <br /> filters is limited to 180 days. <br /> (5)Persons generating,transporting, or receiving used oil filters shall use a bill of lading to record the transfer of <br /> used oil filters. Bills of lading must indicate generator,transporter, and receiving company names, addresses, <br /> telephone numbers,the quantity and size of used oil filter containers transferred, and the date of transfer.A copy of <br /> each bill of lading must be kept on the premises of the generator,transporter, and receiving facility where the used <br /> oil filters were handled. Copies of bills of lading shall be kept for a period of three years. <br /> CORRECTIVE ACTION: Immediately drain all metal oil filters of free-flowing oil, store them in closed, rainproof <br /> containers, label the container with the words"drained used oil filters,"and mark the container with an accumulation <br /> start date. Immediately obtain all missing bill of lading recycling records that can be found. Dispose of all used oil <br /> filters stored on-site greater than one year. Used oil filters not stored, handled and disposed of according to this <br /> section are regulated as hazardous waste. Provide a corrective action statement, disposal records and supporting <br /> Page 7 of 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.