COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2021 4:48:00 PM
Creation date
2/22/2021 2:00:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
763
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
for the speed to change. <br /> Note: Some dispenser configurations may only have one side of the dispenser configured for vapor recovery. For <br /> these dispensers, verify that the VP1000 does not change speed if the other side is authorized to dispense a fuel <br /> other than gasoline. <br /> • To test the tightness of the vapor plumbing installed on the suction side of the system requires a 0-100"water <br /> column gauge. Connect the gauge into the 1/4"test port of the reducing tee. For the location of the test port, <br /> reference the dispenser views in Section 10. Continue by following and completing the START-UP/ NEW <br /> INSTALLATION/WARRANTY/ANNUAL TESTING FORM. <br /> 8 Troubleshooting the VP1OOO <br /> • Use extreme care and caution when performing the tests listed below. If 120 VAC is accidentally applied to the <br /> fault or DC terminals, the module will be destroyed. <br /> • With power applied to the dispenser, but no products authorized, there should be 120 VAC between neutral and <br /> 120 VAC on the module terminal strip. <br /> • As above, with any product authorized, there should be single speed power applied to the VP1000. Verify this by <br /> checking for 2-3 VDC from OUTPUT 1 (RED WIRE)to FAULT COMMON (ORANGE WIRE), (or from OUTPUT <br /> 2 TO FAULT COMMON) also; one GREEN LED should be illuminated. With a second product authorized on the <br /> opposite side of the dispenser i.e. one product on each side, the motor should operate at higher speed and there <br /> should be 2-3 VDC on both output 1 and 2 (to fault common) and both GREEN LED's should be illuminated. <br /> • With the pump running, a fault can be simulated by shorting, with a jumper wire, the "FAULT INPUT" (purple wire) <br /> to FAULT COMMON (orange). This should cause the motor to shut off, the solenoid valves to lose power and <br /> the dispenser to shut down. Also, as long as the short is maintained, the red LED will be illuminated. Removing <br /> the short will not automatically reset the module. To reset the module, remove the short, remove power to the <br /> dispenser for twenty seconds and restore power. The module should now be reset and the red LED extinguished. <br /> This can also be accomplished by using the power reset (PWR RESET) on the module. <br /> • If diagnosing a problem where the LED is already illuminated, a steady light indicates a low current condition, <br /> therefore expect a vane or rotor problem. If the LED is blinking, that indicates a high current condition and one <br /> would expect to find a jammed rotor or vapor line flooded with product. See Start-up/ New Installation/Warranty/ <br /> Annual Testing Form. <br /> • The electronics of the motor will make three attempts to have a successful start of the motor. If it detects a <br /> problem, on the fourth unsuccessful start, it will short the fault line to signal minus (DC-)and shut down the <br /> electronics. <br /> MC100 Interface Module <br /> i r <br /> J <br /> A <br /> esn <br /> ID <br /> GARB Approved IBM 8-Wayne Global Century,Select Reliance Series-Executive Orders VR-201 and VR-202 <br />
The URL can be used to link to this page
Your browser does not support the video tag.