My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/8/2021 4:48:00 PM
Creation date
2/22/2021 2:00:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
763
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Diagnostic Menus <br /> CALIBRATE SMARTSENSOR El HM Mode Backup©Change QEnter <br /> PRESS<ENTER> 4Repressuntil � Key press <br /> desired message 2 sequence <br /> This menu only appears Fs-] F�Function S]Step E Sensor Tank ❑P Print appears in display <br /> if this Smartsensor type <br /> is a pressure sensor. ISD-EVR/fig3.eps <br /> CALIBRATE SMARTSENSOR <br /> PRESS<STEP>TO CONTINUE P Prints out sensor calibration history see example <br /> LR <br /> ESSURE SENSOR <br /> at right.F-slION HISTORY <br /> OR PRESSURE-DD-YY HH:MMs t: VAPOR PRESSUREThis is the current uncalibrated value read by the pressure : XXXXXXXXPRESSURE: -XX.XXX sensor. XXXX.XXXXXXX.XXX❑S TUS: PASS <br /> ENTER ZERO REFERENCE Enter reference pressure value from calibrated test device at <br /> PRESSURE: +XX.XXX pressure sensor via TLS Console front panel,e.g.,ambient <br /> pressure(0.0).This is the first point of the calibration slope. <br /> S <br /> READ ZERO VALUE Wait until the read zero pressure value stabilizes and no longer <br /> PRESSURE: -XX.XXX changes,then press STEP. <br /> ENTER SPAN REFERENCE Enter span reference pressure value from calibrated test device at <br /> PRESSURE: -XX.XXX pressure sensor via TLS Console front panel,e.g.,2 psi.This is <br /> ❑S the second point of the calibration slope. <br /> READ SPAN VALUE Wait until the read span pressure value stabilizes and no longer <br /> .X <br /> PRESSURE: -XXXX changes,then press STEP. <br /> Fc—ALB STATUS:PASS This message will only appear after all 4 values have been <br /> PRESS<STEP>TO CONTINUE successfully obtained and the calibrated slope and offset are <br /> within acceptable limits. <br /> ID-45 <br /> GARB Approved IDM 10 -Veeden Root ISD Install,Setup,D Operation Manual-Executive Order VR-202 <br />
The URL can be used to link to this page
Your browser does not support the video tag.