Laserfiche WebLink
ISD Component Installation Vapor Return Pressure Sensor Installation <br /> Vapor Return Pressure Sensor Installation <br /> VENT STACK INSTALLATION EXAMPLE <br /> 1. A Transmitter/battery pack pair must be installed with the Veeder-Root Vapor Return Pressure Sensor (VRPS) <br /> in the Universal Enclosure and mounted on the vent stack (see Figure 15). <br /> 2. Install the VRPS sensor in the Universal Enclosure following instructions accompanying the sensor. During the <br /> installation, all required National, State and local safety codes must be followed. <br /> 3. Using two #10 taptite screws from the Universal Enclosure kit, attach the Transmitter housing to the side of <br /> the L bracket from the Universal Enclosure kit- do not attach L bracket/transmitter assembly to the back <br /> mounting surface at this time. <br /> 4. Get the battery pack mounting bracket from the Universal Enclosure kit and put the threaded connector fitting <br /> of the battery housing through the large hole in the bracket. <br /> 5. Get the thin hex nut from the kit and screw it onto the battery housing cable connector threaded fitting until <br /> snug (see item 4 in Figure 16). <br /> 6. Attach the battery housing/bracket assembly to the back mounting surface of the Universal Enclosure using <br /> two#10 taptite screws from the kit (see item 5 in Figure 16). <br /> 7. Connect the VRPS and battery cables to the VRPS transmitter as described in the section below entitled <br /> "Connecting Cables To The Transmitter" on page 27, then attach the transmitter/L bracket assembly to the <br /> back mounting surface using two #10 taptite screws from the kit. <br /> I0-24 <br /> CARE Approved IOM 10-Veeder Root TLS RF Wireless Systems(W2)-Executive Order VR-202 <br />