t L 'r 1 Fc.J L��v v✓ <br /> St 10�t Appendix B 00-1 <br /> 71 SO Overfill Valve in Tank Shut off Level Worksheet <br /> Important: This is meant to be supplemental worksheet and not a substitute to following the installation <br /> manual instructions. All length measurements are in inches. Please contact the Authority Having Jurisdic- <br /> tion (AHJ)and review local,state,and national codes to determine the regulatory requirements governing <br /> shut-off capacity in your region,as well as take into account other considerations such as extreme tank tilt. <br /> Take the following measurements with the valve in- <br /> stalled in the tank: <br /> Distance from the 71 SO inlet tube flange to the cast <br /> lug in the 71 SO body(see figures),upper tube length. <br /> Note: the Upper Tube Length must be at least 16"to in- <br /> clude the protective bend in the tube. <br /> Distance from the 71 SO inlet tube flange to the top and <br /> bottom of lower tube,valve length. (D) <br /> (W) = Ijz i�j i T)� <br /> Upper <br /> (U) = I A i 11, 11 yeti Tube <br /> Distance from the 71 SO inlet tube flange to the bottom <br /> of the tank. Note: If a tank bottom protector is present it <br /> may be necessary to add this thickness to dimension 1 <br /> (OPW 6111 &61 TP models add 0.6") (W)Valve e( <br /> (B) _ ��i�� /�Srf= �3��Z� Length, <br /> bottom of <br /> From the tank calibration chart provided by tank manu- cut <br /> facturer find the dipstick number(Y) which corresponds <br /> to the 100°/gvolume. (B) <br /> (Y) = S/ ° j <br /> To Tank <br /> I Y . <br /> 1. To determine shut-off percentage: Tank ti <br /> Subtract upper tube length (D)from distance to tank (U)Valve Chart I) <br /> bottom (B) y Zr Length, 100% 1 <br /> (X) =(B)-(D)-2"_ � �O�5-- 7b r top of cut Volume 1 <br /> Dipstick <br /> Using the tank calibration chart provided by the tank <br /> manufacturer determine the tank capacity at the cal- <br /> culated (X)dimension and the 100%volume(Y) tank <br /> capacity. <br /> (X)tank capacity in gallons=105-66 fJWS - f z�y <br /> (Y)tank capacity in gallons <br /> SO%= (X)capacity/(Y)capacity x100=904 l-- 7/,/ -X <br /> Note: The overfill valve must be installed per AHJ require- <br /> ments and all applicable local,state,and national codes. If <br /> the overfill valve is set above the allowable shut-off percent- <br /> age the overfill valve must be removed and replaced. For <br /> reference 40 CFR part 280 Subpart B Section 280.20 overfill <br /> valves should be set to-a maximum of 95%. <br /> 21 <br />