FGL Environmental Doc ID: 3DO900002_SOP_12.DOC <br /> Revision Date: 10/09/14 Page 1 of 1 <br /> Inter- Condition U on Receipt (Attach to COC) -5131 <br /> Sample Receipt at: STK C CH VI <br /> 1. Number of ice chests/ ages received: Shipping tracking# <br /> 4- <br /> 2. Were samples received in a chilled condition? Temps: / 11—/ <br /> Surface water SWTR bact samples: A sample that has a temperature upon receipt of >100 C,whether iced or not, <br /> should be flagged unless the time since sample collection has been less than two hours. <br /> 3. Do the number of bottles received agree with the COC? No N/A <br /> 4. Were samples received intact? (i.e. no broken bottles, leaks etc.) a No <br /> 5. VOAs checked for Headspace? Yes No CAT <br /> 6. Were sample custody seals intact? Yes No <br /> 7. If required, was sample split for pH analysis? Yes No <br /> 8. Were all analyses within holding times at time of receipt? No <br /> 9. Verify sample date,time and sampler name No <br /> Sign and date the COC, place in a ziplock and put in 2ip same ice chest aXte mples. <br /> Sample Receipt Review completed by (initials): <br /> Sample Receipt at SP: <br /> 1. Were samples received in a chilled condition? Temps: <br /> Acceptable is above freezing to 6-w C. If many packages are received at one timecheck for tes T.'s/rushes/ <br /> 2. Shipping tracking numbers: <br /> kw) <br /> _I401,3 �E�, <br /> 3. Do the number of bottles received agree with the COC? No N/A <br /> 4. Were samples received intact? (i.e. no broken bottles, leaks etc.) No <br /> 5. Were sample custody seals intact? Yes No <br /> Sign and date the COC, obtain LIMS sample numbers, select methods/tests and print labels. <br /> Sample Verification, Labeling and Distribution: <br /> 1. Were all requested analyses understood and acceptable? No <br /> 2. Did bottle labels correspond with the client's ID's? es No <br /> 3. Were all bottles requiring sample preservation properly preserved? Yes No ( /� FGL <br /> lException:Oil&Grease,VOA and CrVI verified in lab] <br /> 4. VOAs checked for Headspace? Yes No / <br /> 5. Have rush or project due dates been checked and accepted? Ye No N A <br /> 6. Were all analyses within holding times at time of receipt? es No <br /> Attach labels to the containers and include a copy of the COC for lab delivery. <br /> Sample Receipt, Login and Verification completed by (initials): <br /> Discrepancy Documentation: <br /> Any items above which are "No"or do not meet specifications (i.e. temps) must be resolved. <br /> 1. Person Contacted: Phone Number: <br /> Initiated By: Date: <br /> Problem: <br /> Resolution: <br /> 2. Person Contacted: <br /> Initiated By: (3016608) <br /> Problem: <br /> Resolution: Live Oak Geo Mronmenhl <br /> (Please use the back of this sheet for additional con STRM-1311 <br /> contacts) lv 011281202111:39:16 <br />