Laserfiche WebLink
ENVIRONMENTAL AGRICULTURAL <br /> Analytical Chendsts <br /> February 18,2021 Lab ID : STK2132063 <br /> Live Oak Geo Environmental Customer : 3-16608 <br /> Quality Control- Organic <br /> Constituent Method Date/ID Type Units (,unt. QC Data I)QO Note <br /> Organic <br /> 1,2-Dibromoethane(EDB) 504 02/13/21:201606JMR Blank ug/L ND <0.02 <br /> LCS ug/L 0.2522 104% 70-130 <br /> LCS ug/L 0.2541 112% 70-130 <br /> MS ug/L 0.2388 111% 70-130 <br /> (STK2131740-001) MSD ug/L 0.2389 102% 70-130 <br /> MSRPD ug/L 0.5607 9.0% S30 <br /> MDL I ug/L 0.01969 66.7% 1 60-140 <br /> 13-Dibromopropane 504 02/13/21:201606JMR Blank ug/L 0.5799 85.2% 70-130 <br /> LCS ug/L 0.5920 90.9% 70-130 <br /> LCS ug/L 0.5964 983% 70-130 <br /> MS ug/L 0.5606 90.5% 70-130 <br /> (STK2131740-001) MSD ug/L 0.5607 82.7% 70-130 <br /> MSRPD ug/L 0.5607 9.1% S30 <br /> QMDL I ug/L 0.5818 102% 1 70-130 <br /> BCP 504 02/13/21:201606JMR Blank ug/L ND <0.01 <br /> LCS ug/L 0.2522 104% 70-130 <br /> LCS ug/L 0.2541 112% 70-130 <br /> MS ug/L 0.2388 105% 70-130 <br /> (STK2131740-001) MSD ug/L 0.2389 96.4% 70-130 <br /> MSRPD ug/L 0.5607 83% Si0 <br /> QMDL I ug/L 0.01969 1 122% 60-140 <br /> 13DBP 504.1 02/14/21:202177JMR CCV ug/L 9.975 98.7% 70-130 <br /> CCV -ug/L 7.481 108% 70-130 <br /> BCP 504.1 02/14121:202177JMR CCV ug/L 5.000 97.2% 70-130 <br /> CCV ug/L 2.000 114% 70-130 <br /> DB 504.1 02/14/21:202177JMR CCV ug/L 5.000 97.6% 70-130 <br /> CCV ug/L 1 2.000 98.0% 1 70-130 <br /> Definition <br /> CCV :Continuing Calibration Verification-Analyzed to verify the instrument calibration is within criteria. <br /> Blank :Method Blank-Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS :Laboratory Control Standard/Sample-Prepared to verify that the preparation process is not affecting analyte recovery. <br /> MS :Matrix Spikes-A random sample is spiked with a known amount of analyte.The recoveries are an indication of how that sample <br /> matrix affects analyte recovery. <br /> MSD :Matrix Spike Duplicate of MS/MSD pair-A random sample duplicate is spiked with a known amount of analyte.The recoveries <br /> are an indication of how that sample matrix affects analyte recovery. <br /> MSRPD :MS/MSD Relative Percent Difference(RPD)- rhe MS relative percent difference is an indication of precision for the preparation <br /> and analysis. <br /> ND :Non-detect-Result was below the DQO listed for the analyte. <br /> DQO Data Quality Objective-This is the criteria against which the quality control data is compared. <br /> Page 5 of 6 <br /> Corporate Offices&Laboratory Office&Laboratory Office&Laboratory Office&Laboratory Office&Laboratory <br /> 853 Corporation Street 2500 Stagecoach Road 563 E.Lindo Avenue 3442 Empresa Drive,Suite D 9415 W.Goshen Avenue <br /> Santa Paula,CA 93060 Stockton,CA 95215 Chico,CA 95926 San Luis Obispo,CA 93401 Visalia,CA 93291 <br /> TEL:(805)392-2000 TEL:(209)942-0182 TEL:(530)343-5818 TEL:(805)783-2940 TEL:(559)734-9473 <br /> Env FAX:(805)525-4172/Ag FAX:(805)392-2063 FAX:(209)942-0423 FAX:(530)343-3807 FAX:(805)783-2912 FAX:(559)734-8435 <br /> CA ELAP Certification No.1573 CA ELAP Certification No.1563 CA ELAP Certification No.2670 CA ELAP Certification No.2775 CA ELAP Certification No.2810 <br />