Laserfiche WebLink
SAN. IOAQUIN Environmental Health Department <br /> COUNTY <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SMART TECH DIESEL REPAIR 795 E ROTH RD, FRENCH CAMP October 15, 2020 <br /> Universal Waste <br /> 715 HSC 25201.16(g) Failed to store UW aerosol cans in an accumulation container ri V ❑R u COS <br /> 716 CCR 66273.40(a)(3)(4) UW handler sending devices/CRTs/CRT glass to foreign destination failed to submit notification ❑V ❑R ❑COS <br /> 717 CCR 66273.32(b) UWH failed to obtain an ID number from DTSC prior to accumulating>5000kg of non-RCRA UW ❑V ❑R ❑COS <br /> 718 CCR 66273.32(d) Failure of a UW handler to submit a complete annual report to DTSC ❑V ❑R ❑COS <br /> 719 CCR 66273.38 Failed to transfer UW using packaging and shipping papers to an appropriate destination facility ❑V ❑R ❑COS <br /> 720 CCR 66273.8(b), Disposed of UW or failed to transfer UW to an appropriate destination facility ❑V ❑R ❑COS <br /> 66273.31(a) <br /> Appliance Recycler <br /> 801 HSC 25211.4 Failure to obtain Certified Appliance Recycler certification(CAR) ❑V ❑R u COS <br /> 802 HSC 25211.2,25211.3 Failure of a CAR to provide docs that materials that require special handling have been removed ❑V ❑R ❑COS <br /> 803 HSC 25212 Failure of a CAR to properly remove and dispose of all materials that require special handling ❑V ❑R n COS <br /> Other Violations <br /> 3010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 3020 See below Unlisted Training violation ❑V ❑R c COS <br /> 3030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 3040 See below Unlisted Release/Leaks/Spills violation ❑V ❑R ❑COS <br /> 3050 See below Unlisted AbandonmenUillegal Disposal/Unauthorized Treatment violation n V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 CCR 66262.11 Failed to determine if a waste is a hazardous waste. <br /> OBSERVATIONS: Dark staining was observed on the ground in the backyard of the shop. The stained area was <br /> approximately 10x5 feet. According to the president,Amandeep Singh,employees will dump tap water used for fire <br /> suppression onto the ground for disposal. Employees are not allowed to dump any other waste in that area. <br /> REGULATION GUIDANCE: Any person who generates a waste shall determine if the waste is a hazardous waste <br /> as specified in Title 22 California Code of Regulations(CCR). There are wastes that are listed as hazardous <br /> wastes. There are wastes that exhibit one or more of the hazardous waste characteristics:toxic,corrosive, reactive <br /> or ignitable. <br /> CORRECTIVE ACTION: Immediately cease disposal, make a hazardous waste determination for the water and <br /> the stained soil,and manage it according to Title 22 CCR. Use Safety Data Sheets(SDS),waste sampling and test <br /> results or other knowledge to support your hazardous waste determination. Waste testing must be done using <br /> methods specified in Title 22 CCR including sections 66261.20-24. <br /> Submit a statement and supporting documentation with your hazardous waste determination. Demonstrate current <br /> storage and labeling for wastes determined to be hazardous wastes. Provide disposal records for wastes <br /> determined to be hazardous wastes and stored longer than the number of days specified in Title 22 CCR for your <br /> hazardous waste generator status. <br /> This is a Class II violation. <br /> FA0016092 PRO546244 SCO01 10/15/2020 <br /> EHD 22-02 Rev.9/16/2020 Page 4 of 18 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />