Laserfiche WebLink
CASTLE ANALYTICAL LABORATORY <br /> Environmental Testing Services 2333 Shuttle Drive,Atwater,CA 95301 Phone: (209)384-2930 <br /> Certificate No.2480 Fax: (209)384-1507 <br /> Shop Hazard Solutions, Inc. Client Project Name:Mariposa/Van Allen Method:TPH-Diesel <br /> P.O.Box 798 Lab Reference Number:2009021 Instrument ID: HP-Diesel <br /> Turlock,CA 95381 Sample Description:Soil Extracted:09-09-20 <br /> Attn:Steve Meier Analyzed: 09-09-20 <br /> Reported:09-10-20 <br /> QUALITY CONTROL DATA REPORT <br /> ANALYTE TPH-Diesel <br /> Spike Concentration: 5.00 <br /> Units: mg/kg <br /> Batch#: TPHDS-9090 <br /> Method Blank: ND <br /> Surrogate%Recovery: 114% <br /> LCS%Recovery: See LCSA/LCSB <br /> Surrogate%Recovery: <br /> Control Limits: 60-130% <br /> LCSA/LCSB Batch#: TPHDS-9090 <br /> LCSA%Recovery: 133% <br /> Surrogate%Recovery: 89.2% <br /> LCSB%Recovery: 133% <br /> Surrogate%Recovery: 90.5% <br /> Relative%Difference: 0.07% <br /> Please Note: <br /> The LCS(Laboratory Check Sample)is a control sample of known, interferent free matrix that is fortified with representative analytes and <br /> analyzed using the same reagents,preparation and analytical methods employed for the samples. The LCS%recovery is used for validation <br /> of sample batch results. Due to matrix effects,the QC limits and recoveries for MS/MSD's are advisory only and are not used to accept or <br /> reject batch results. <br /> APPROVED BY: <br /> Clan J. Cone/Labordtory Director <br /> Cassandra J.A. NqWney/Chemist <br />